메뉴 건너뛰기




Volumn 27, Issue 10, 2008, Pages

Field 6. Safety practices for haemodynamic procedures (administration of vasoactive drugs, vascular and cardiac catheterization);Champ 6. Sécurisation des procédures « circulatoires » (administration des substances vasoactives, utilisation des cathéters artériels, veineux centraux et artériels pulmonaires)

Author keywords

Arterials catheters; Human errors; Patient adverse event; Pulmonary arterial catheters; Vasoactive drugs; Venous catheters

Indexed keywords

ADRENALIN; DOBUTAMINE; DOPAMINE; ENOXIMONE; INOTROPIC AGENT; LEVOSIMENDAN; NORADRENALIN; VASOACTIVE AGENT; VASOPRESSIN;

EID: 55649097743     PISSN: 07507658     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.annfar.2008.09.012     Document Type: Article
Times cited : (14)

References (71)
  • 1
    • 0037471825 scopus 로고    scopus 로고
    • Ethnographic study of incidence and severity of intravenous drug errors
    • Taxis K., and Barber N. Ethnographic study of incidence and severity of intravenous drug errors. BMJ 326 (2003) 684
    • (2003) BMJ , vol.326 , pp. 684
    • Taxis, K.1    Barber, N.2
  • 2
    • 0035102689 scopus 로고    scopus 로고
    • Analysis of the French health ministry's national register of incidents involving medical devices in anaesthesia and intensive care
    • Beydon L., Conreux F., Le Gall R., Safran D., and Cazalaà J.B. Analysis of the French health ministry's national register of incidents involving medical devices in anaesthesia and intensive care. Br J Anaesth 86 (2001) 382-387
    • (2001) Br J Anaesth , vol.86 , pp. 382-387
    • Beydon, L.1    Conreux, F.2    Le Gall, R.3    Safran, D.4    Cazalaà, J.B.5
  • 4
    • 14944351088 scopus 로고    scopus 로고
    • A controlled trial of smart infusion pumps to improve medication safety in critically ill patients
    • Rothschild J.M., Keohane C.A., Cook E.F., Orav E.J., Burdick E., Thompson S., et al. A controlled trial of smart infusion pumps to improve medication safety in critically ill patients. Crit Care Med 33 (2005) 533-540
    • (2005) Crit Care Med , vol.33 , pp. 533-540
    • Rothschild, J.M.1    Keohane, C.A.2    Cook, E.F.3    Orav, E.J.4    Burdick, E.5    Thompson, S.6
  • 5
    • 1242342729 scopus 로고    scopus 로고
    • Medication errors involving continuously infused medications in a surgical intensive care unit
    • Herout P.M., and Erstad B.L. Medication errors involving continuously infused medications in a surgical intensive care unit. Crit Care Med 32 (2004) 428-432
    • (2004) Crit Care Med , vol.32 , pp. 428-432
    • Herout, P.M.1    Erstad, B.L.2
  • 6
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss M., Banziger O., Neff T., and Fanconi S. Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med 26 (2000) 776-779
    • (2000) Intensive Care Med , vol.26 , pp. 776-779
    • Weiss, M.1    Banziger, O.2    Neff, T.3    Fanconi, S.4
  • 7
    • 0035089356 scopus 로고    scopus 로고
    • Infusion pump performance with vertical displacement: effect of syringe pump and assembly type
    • Neff T.A., Fischer J.E., Schulz G., Baenziger O., and Weiss M. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intensive Care Med 27 (2001) 287-291
    • (2001) Intensive Care Med , vol.27 , pp. 287-291
    • Neff, T.A.1    Fischer, J.E.2    Schulz, G.3    Baenziger, O.4    Weiss, M.5
  • 11
    • 0036087258 scopus 로고    scopus 로고
    • Clinical review: complications and risk factors of peripheral arterial catheters used for hemodynamic monitoring in anaesthesia and intensive care medicine
    • Scheer B., Perel A., and Pfeiffer U.J. Clinical review: complications and risk factors of peripheral arterial catheters used for hemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 6 (2002) 199-204
    • (2002) Crit Care , vol.6 , pp. 199-204
    • Scheer, B.1    Perel, A.2    Pfeiffer, U.J.3
  • 12
    • 0021827152 scopus 로고
    • Radial artery cannulation and ischaemic damage: a review
    • Wilkins R.G. Radial artery cannulation and ischaemic damage: a review. Anaesthesia 40 (1985) 896-899
    • (1985) Anaesthesia , vol.40 , pp. 896-899
    • Wilkins, R.G.1
  • 13
    • 0017178184 scopus 로고
    • Critique of the Allen test for continuity of the palmar arch assessed by doppler ultrasound
    • Kamienski R.W., and Barnes R.W. Critique of the Allen test for continuity of the palmar arch assessed by doppler ultrasound. Surg Gynecol Obstet 142 (1976) 861-864
    • (1976) Surg Gynecol Obstet , vol.142 , pp. 861-864
    • Kamienski, R.W.1    Barnes, R.W.2
  • 14
    • 0017893436 scopus 로고
    • Radial artery cannulation: influence of catheter size and material on arterial occlusion
    • Davis F.M. Radial artery cannulation: influence of catheter size and material on arterial occlusion. Anaesth Intensive Care 6 (1978) 49-53
    • (1978) Anaesth Intensive Care , vol.6 , pp. 49-53
    • Davis, F.M.1
  • 15
    • 0043234290 scopus 로고    scopus 로고
    • Ultrasonic locating devices for central venous cannulation: meta-analysis
    • Hind D., Calvert N., McWilliams R., Davidson A., Paisley S., Beverley C., et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 327 (2003) 361
    • (2003) BMJ , vol.327 , pp. 361
    • Hind, D.1    Calvert, N.2    McWilliams, R.3    Davidson, A.4    Paisley, S.5    Beverley, C.6
  • 16
    • 0037323897 scopus 로고    scopus 로고
    • Use of ultrasound guidance in the insertion of radial artery catheters
    • Levin P.D., Sheinin O., and Gozal Y. Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med 31 (2003) 481-484
    • (2003) Crit Care Med , vol.31 , pp. 481-484
    • Levin, P.D.1    Sheinin, O.2    Gozal, Y.3
  • 17
    • 0027504029 scopus 로고
    • Lemakalim, a potassium channel agonist, reverses electrophysiological impairments induced by a large dose of bupivacaine in anaesthetized dogs
    • de La Coussaye J.E., Eledjam J.J., Peray P., Bruelle P., Lefrant J.Y., Bassoul B., et al. Lemakalim, a potassium channel agonist, reverses electrophysiological impairments induced by a large dose of bupivacaine in anaesthetized dogs. Br J Anaesth 71 (1993) 534-539
    • (1993) Br J Anaesth , vol.71 , pp. 534-539
    • de La Coussaye, J.E.1    Eledjam, J.J.2    Peray, P.3    Bruelle, P.4    Lefrant, J.Y.5    Bassoul, B.6
  • 18
    • 0032406795 scopus 로고    scopus 로고
    • Intraoperative heparin flushes and subsequent acute heparin-induced thrombocytopenia
    • Ling E., and Warkentin T.E. Intraoperative heparin flushes and subsequent acute heparin-induced thrombocytopenia. Anesthesiology 89 (1998) 1567-1569
    • (1998) Anesthesiology , vol.89 , pp. 1567-1569
    • Ling, E.1    Warkentin, T.E.2
  • 19
    • 0025903815 scopus 로고
    • Comparison of normal saline and heparin solutions for maintenance of arterial catheter patency
    • Clifton G.D., Branson P., Kelly H.J., Dotson L.R., Record K.E., Phillips B.A., et al. Comparison of normal saline and heparin solutions for maintenance of arterial catheter patency. Heart Lung 20 (1991) 115-118
    • (1991) Heart Lung , vol.20 , pp. 115-118
    • Clifton, G.D.1    Branson, P.2    Kelly, H.J.3    Dotson, L.R.4    Record, K.E.5    Phillips, B.A.6
  • 20
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature
    • Randolph A.G., Cook D.J., Gonzales C.A., and Pribble C.G. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 24 (1996) 2053-2058
    • (1996) Crit Care Med , vol.24 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3    Pribble, C.G.4
  • 21
    • 0030638899 scopus 로고    scopus 로고
    • Comparison of heparinized and nonheparinized solutions for maintaining patency of arterial and pulmonary artery catheters
    • Zevola D.R., Dioso J., and Moggio R. Comparison of heparinized and nonheparinized solutions for maintaining patency of arterial and pulmonary artery catheters. Am J Crit Care 6 (1997) 52-55
    • (1997) Am J Crit Care , vol.6 , pp. 52-55
    • Zevola, D.R.1    Dioso, J.2    Moggio, R.3
  • 22
    • 0028198435 scopus 로고
    • Heparinized saline versus normal saline in maintaining patency of the radial artery catheter
    • Kulkarni M., Elsner C., Ouellet D., and Zeldin R. Heparinized saline versus normal saline in maintaining patency of the radial artery catheter. Can J Surg 37 (1994) 37-42
    • (1994) Can J Surg , vol.37 , pp. 37-42
    • Kulkarni, M.1    Elsner, C.2    Ouellet, D.3    Zeldin, R.4
  • 23
    • 33750094163 scopus 로고    scopus 로고
    • Comparison of normal or heparinised saline flushing on function of arterial lines
    • Whitta R.K., Hall K.F., Bennetts T.M., Welman L., and Rawlins P. Comparison of normal or heparinised saline flushing on function of arterial lines. Crit Care Resusc 8 (2006) 205-208
    • (2006) Crit Care Resusc , vol.8 , pp. 205-208
    • Whitta, R.K.1    Hall, K.F.2    Bennetts, T.M.3    Welman, L.4    Rawlins, P.5
  • 24
    • 0027512294 scopus 로고
    • Efficacy of 1.4 percent sodium citrate in maintaining arterial catheter patency in patients in a medical ICU
    • Branson P.K., McCoy R.A., Phillips B.A., and Clifton G.D. Efficacy of 1.4 percent sodium citrate in maintaining arterial catheter patency in patients in a medical ICU. Chest 103 (1993) 882-885
    • (1993) Chest , vol.103 , pp. 882-885
    • Branson, P.K.1    McCoy, R.A.2    Phillips, B.A.3    Clifton, G.D.4
  • 25
    • 0027217696 scopus 로고
    • Double-blind, randomized, controlled trial of papaverine-containing infusions to prevent failure of arterial catheters in pediatric patients
    • Heulitt M.J., Farrington E.A., O'Shea T.M., Stoltzman S.M., Srubar N.B., and Levin D.L. Double-blind, randomized, controlled trial of papaverine-containing infusions to prevent failure of arterial catheters in pediatric patients. Crit Care Med 21 (1993) 825-829
    • (1993) Crit Care Med , vol.21 , pp. 825-829
    • Heulitt, M.J.1    Farrington, E.A.2    O'Shea, T.M.3    Stoltzman, S.M.4    Srubar, N.B.5    Levin, D.L.6
  • 26
    • 0019492519 scopus 로고
    • The effect of method of radial artery cannulation on postcannulation blood flow and thrombus formation
    • Jones R.M., Hill A.B., Nahrwold M.L., and Bolles R.E. The effect of method of radial artery cannulation on postcannulation blood flow and thrombus formation. Anesthesiology 55 (1981) 76-78
    • (1981) Anesthesiology , vol.55 , pp. 76-78
    • Jones, R.M.1    Hill, A.B.2    Nahrwold, M.L.3    Bolles, R.E.4
  • 27
    • 0017922194 scopus 로고
    • Long-term radial artery cannulation: effects on subsequent vessel function
    • Bedford R.F. Long-term radial artery cannulation: effects on subsequent vessel function. Crit Care Med 6 (1978) 64-67
    • (1978) Crit Care Med , vol.6 , pp. 64-67
    • Bedford, R.F.1
  • 28
    • 0020617745 scopus 로고
    • On the safety of radial artery cannulation
    • Slogoff S., Keats A.S., and Arlund C. On the safety of radial artery cannulation. Anesthesiology 59 (1983) 42-47
    • (1983) Anesthesiology , vol.59 , pp. 42-47
    • Slogoff, S.1    Keats, A.S.2    Arlund, C.3
  • 29
    • 0031951612 scopus 로고    scopus 로고
    • Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients
    • Frezza E.E., and Mezghebe H. Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. Am Surg 64 (1998) 127-131
    • (1998) Am Surg , vol.64 , pp. 127-131
    • Frezza, E.E.1    Mezghebe, H.2
  • 30
    • 0027364679 scopus 로고
    • Nonphysician placement of arterial catheters. Experience with 500 insertions
    • Gronbeck III C., and Miller E.L. Nonphysician placement of arterial catheters. Experience with 500 insertions. Chest 104 (1993) 1716-1717
    • (1993) Chest , vol.104 , pp. 1716-1717
    • Gronbeck III, C.1    Miller, E.L.2
  • 31
    • 0027459505 scopus 로고
    • Broken needle complicating arterial cannulation
    • Ramsay T.M. Broken needle complicating arterial cannulation. Anaesthesia 48 (1993) 178
    • (1993) Anaesthesia , vol.48 , pp. 178
    • Ramsay, T.M.1
  • 32
    • 12244306921 scopus 로고    scopus 로고
    • The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population
    • [discussion 234-5]
    • Deshpande K.S., Hatem C., Ulrich H.L., Currie B.P., Aldrich T.K., Bryan-Brown C.W., et al. The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population. Crit Care Med 33 (2005) 13-20 [discussion 234-5]
    • (2005) Crit Care Med , vol.33 , pp. 13-20
    • Deshpande, K.S.1    Hatem, C.2    Ulrich, H.L.3    Currie, B.P.4    Aldrich, T.K.5    Bryan-Brown, C.W.6
  • 33
    • 0031991101 scopus 로고    scopus 로고
    • Complication of femoral artery pressure monitoring
    • Muralidhar K. Complication of femoral artery pressure monitoring. J Cardiothorac Vasc Anesth 12 (1998) 128-129
    • (1998) J Cardiothorac Vasc Anesth , vol.12 , pp. 128-129
    • Muralidhar, K.1
  • 34
    • 0029148091 scopus 로고
    • The prevalence of nosocomial infection in intensive care units in Europe. Results of the European Prevalence of Infection in Intensive Care (EPIC) Study. EPIC International Advisory Committee
    • Vincent J.L., Bihari D.J., Suter P.M., Bruining H.A., White J., Nicolas-Chanoin M.H., et al. The prevalence of nosocomial infection in intensive care units in Europe. Results of the European Prevalence of Infection in Intensive Care (EPIC) Study. EPIC International Advisory Committee. JAMA 274 (1995) 639-644
    • (1995) JAMA , vol.274 , pp. 639-644
    • Vincent, J.L.1    Bihari, D.J.2    Suter, P.M.3    Bruining, H.A.4    White, J.5    Nicolas-Chanoin, M.H.6
  • 35
    • 0037456765 scopus 로고    scopus 로고
    • Preventing complications of central venous catheterization
    • McGee D.C., and Gould M.K. Preventing complications of central venous catheterization. N Engl J Med 348 (2003) 1123-1133
    • (2003) N Engl J Med , vol.348 , pp. 1123-1133
    • McGee, D.C.1    Gould, M.K.2
  • 36
    • 0033522513 scopus 로고    scopus 로고
    • Use of tunneled femoral catheters to prevent catheter-related infection. A randomized, controlled trial
    • Timsit J.F., Bruneel F., Cheval C., Mamzer M.F., Garrouste-Orgeas M., Wolff M., et al. Use of tunneled femoral catheters to prevent catheter-related infection. A randomized, controlled trial. Ann Intern Med 130 (1999) 729-735
    • (1999) Ann Intern Med , vol.130 , pp. 729-735
    • Timsit, J.F.1    Bruneel, F.2    Cheval, C.3    Mamzer, M.F.4    Garrouste-Orgeas, M.5    Wolff, M.6
  • 37
    • 0035827890 scopus 로고    scopus 로고
    • Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial
    • Merrer J., De Jonghe B., Golliot F., Lefrant J.Y., Raffy B., Barre E., et al. Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA 286 (2001) 700-707
    • (2001) JAMA , vol.286 , pp. 700-707
    • Merrer, J.1    De Jonghe, B.2    Golliot, F.3    Lefrant, J.Y.4    Raffy, B.5    Barre, E.6
  • 38
    • 84941817891 scopus 로고
    • Central vein catheterisation. Failure and complication rates by three percutaneous approaches
    • Sznajder J.I., Zveibil F.R., Bitterman H., Weiner P., and Bursztein S. Central vein catheterisation. Failure and complication rates by three percutaneous approaches. Arch Intern Med 146 (1986) 259-261
    • (1986) Arch Intern Med , vol.146 , pp. 259-261
    • Sznajder, J.I.1    Zveibil, F.R.2    Bitterman, H.3    Weiner, P.4    Bursztein, S.5
  • 39
    • 0036360971 scopus 로고    scopus 로고
    • Risk factors of failure and immediate complication of subclavian vein catheterization in critically ill patients
    • Lefrant J.Y., Muller L., de La Coussaye J.E., Prudhomme M., Ripart J., Gouzes, et al. Risk factors of failure and immediate complication of subclavian vein catheterization in critically ill patients. Intensive Care Med 28 (2002) 1036-1041
    • (2002) Intensive Care Med , vol.28 , pp. 1036-1041
    • Lefrant, J.Y.1    Muller, L.2    de La Coussaye, J.E.3    Prudhomme, M.4    Ripart, J.5    Gouzes6
  • 41
    • 0035092534 scopus 로고    scopus 로고
    • Long-term arterial cannulation in ICU patients using the radial artery or dorsalis pedis artery
    • Martin C., Saux P., Papazian L., and Gouin F. Long-term arterial cannulation in ICU patients using the radial artery or dorsalis pedis artery. Chest 119 (2001) 901-906
    • (2001) Chest , vol.119 , pp. 901-906
    • Martin, C.1    Saux, P.2    Papazian, L.3    Gouin, F.4
  • 42
    • 34247335065 scopus 로고    scopus 로고
    • Central venous catheterization
    • Taylor R.W., and Palagiri A.V. Central venous catheterization. Crit Care Med 35 (2007) 1390-1396
    • (2007) Crit Care Med , vol.35 , pp. 1390-1396
    • Taylor, R.W.1    Palagiri, A.V.2
  • 44
    • 0021363346 scopus 로고
    • Aberrant locations and complications in initial placement of subclavian vein catheters
    • Conces Jr. D.J., and Holden R.W. Aberrant locations and complications in initial placement of subclavian vein catheters. Arch Surg 119 (1984) 293-295
    • (1984) Arch Surg , vol.119 , pp. 293-295
    • Conces Jr., D.J.1    Holden, R.W.2
  • 45
    • 0036168422 scopus 로고    scopus 로고
    • Complications of central venous catheters: internal jugular versus subclavian access: a systematic review
    • Ruesch S., Walder B., and Tramer M.R. Complications of central venous catheters: internal jugular versus subclavian access: a systematic review. Crit Care Med 30 (2002) 454-460
    • (2002) Crit Care Med , vol.30 , pp. 454-460
    • Ruesch, S.1    Walder, B.2    Tramer, M.R.3
  • 46
    • 0022617484 scopus 로고
    • Improved house staff results with subclavian cannulation
    • Fares II L.G., Block P.H., and Feldman S.D. Improved house staff results with subclavian cannulation. Am Surg 52 (1986) 108-111
    • (1986) Am Surg , vol.52 , pp. 108-111
    • Fares II, L.G.1    Block, P.H.2    Feldman, S.D.3
  • 47
    • 0036865045 scopus 로고    scopus 로고
    • Apprentissage du cathétérisme de la veine sous-clavière chez l'adulte : apport de l'assistance échographique en temps réel
    • Forestier F., Rossi H., Calderon J., Soubiron L., Bourdarias B., and Janvier G. Apprentissage du cathétérisme de la veine sous-clavière chez l'adulte : apport de l'assistance échographique en temps réel. Ann Fr Anesth Reanim 21 (2002) 698-702
    • (2002) Ann Fr Anesth Reanim , vol.21 , pp. 698-702
    • Forestier, F.1    Rossi, H.2    Calderon, J.3    Soubiron, L.4    Bourdarias, B.5    Janvier, G.6
  • 48
    • 0036367610 scopus 로고    scopus 로고
    • Central venous access in intensive care unit patients: is the subclavian vein the royal route?
    • Timsit J.F. Central venous access in intensive care unit patients: is the subclavian vein the royal route?. Intensive Care Med 28 (2002) 1006-1008
    • (2002) Intensive Care Med , vol.28 , pp. 1006-1008
    • Timsit, J.F.1
  • 49
    • 0030057294 scopus 로고    scopus 로고
    • Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography
    • Troianos C.A., Kuwik R.J., Pasqual J.R., Lim A.J., and Odasso D.P. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anesthesiology 85 (1996) 43-48
    • (1996) Anesthesiology , vol.85 , pp. 43-48
    • Troianos, C.A.1    Kuwik, R.J.2    Pasqual, J.R.3    Lim, A.J.4    Odasso, D.P.5
  • 50
    • 0025214546 scopus 로고
    • Misplacement of subclavian venous catheters: importance of head position and choice of puncture site
    • Sanchez R., Halck S., Walther-Larsen S., and Heslet L. Misplacement of subclavian venous catheters: importance of head position and choice of puncture site. Br J Anaesth 64 (1990) 632-633
    • (1990) Br J Anaesth , vol.64 , pp. 632-633
    • Sanchez, R.1    Halck, S.2    Walther-Larsen, S.3    Heslet, L.4
  • 51
    • 10944270992 scopus 로고    scopus 로고
    • Direction of the J-tip of the guidewire, in seldinger technique, is a significant factor in misplacement of subclavian vein catheter: a randomized, controlled study
    • Tripathi M., Dubey P.K., and Ambesh S.P. Direction of the J-tip of the guidewire, in seldinger technique, is a significant factor in misplacement of subclavian vein catheter: a randomized, controlled study. Anesth Analg 100 (2005) 21-24
    • (2005) Anesth Analg , vol.100 , pp. 21-24
    • Tripathi, M.1    Dubey, P.K.2    Ambesh, S.P.3
  • 52
    • 0027293750 scopus 로고
    • Accurate placement of central venous catheters: a prospective, randomized, multicenter trial
    • McGee W.T., Ackerman B.L., Rouben L.R., Prasad V.M., Bandi V., and Mallory D.L. Accurate placement of central venous catheters: a prospective, randomized, multicenter trial. Crit Care Med 21 (1993) 1118-1123
    • (1993) Crit Care Med , vol.21 , pp. 1118-1123
    • McGee, W.T.1    Ackerman, B.L.2    Rouben, L.R.3    Prasad, V.M.4    Bandi, V.5    Mallory, D.L.6
  • 53
    • 0026746473 scopus 로고
    • A controlled trial of scheduled replacement of central venous and pulmonary-artery catheters
    • Cobb D.K., High K.P., Sawyer R.G., Sable C.A., Adams R.B., Lindley D.A., et al. A controlled trial of scheduled replacement of central venous and pulmonary-artery catheters. N Engl J Med 327 (1992) 1062-1068
    • (1992) N Engl J Med , vol.327 , pp. 1062-1068
    • Cobb, D.K.1    High, K.P.2    Sawyer, R.G.3    Sable, C.A.4    Adams, R.B.5    Lindley, D.A.6
  • 54
    • 20444391391 scopus 로고    scopus 로고
    • A randomized controlled clinical trial of real-time needle-guided ultrasound for internal jugular venous cannulation in a large university anesthesia department
    • Augoustides J.G., Horak J., Ochroch A.E., Vernick W.J., Gambone A.J., Weiner J., et al. A randomized controlled clinical trial of real-time needle-guided ultrasound for internal jugular venous cannulation in a large university anesthesia department. J Cardiothorac Vasc Anesth 19 (2005) 310-315
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , pp. 310-315
    • Augoustides, J.G.1    Horak, J.2    Ochroch, A.E.3    Vernick, W.J.4    Gambone, A.J.5    Weiner, J.6
  • 55
    • 0025301215 scopus 로고
    • Ultrasound guidance improves the success rate of internal jugular vein cannulation. A prospective, randomized trial
    • Mallory D.L., McGee W.T., Shawker T.H., Brenner M., Bailey K.R., Evans R.G., et al. Ultrasound guidance improves the success rate of internal jugular vein cannulation. A prospective, randomized trial. Chest 98 (1990) 157-160
    • (1990) Chest , vol.98 , pp. 157-160
    • Mallory, D.L.1    McGee, W.T.2    Shawker, T.H.3    Brenner, M.4    Bailey, K.R.5    Evans, R.G.6
  • 56
    • 0031977096 scopus 로고    scopus 로고
    • Pulsed Doppler ultrasonography guidance for catheterization of the subclavian vein: a randomized study
    • Lefrant J.Y., Cuvillon P., Bénézet J.F., Dauzat M., Peray P., Saïssi G., et al. Pulsed Doppler ultrasonography guidance for catheterization of the subclavian vein: a randomized study. Anesthesiology 88 (1998) 1195-1201
    • (1998) Anesthesiology , vol.88 , pp. 1195-1201
    • Lefrant, J.Y.1    Cuvillon, P.2    Bénézet, J.F.3    Dauzat, M.4    Peray, P.5    Saïssi, G.6
  • 57
    • 0031724390 scopus 로고    scopus 로고
    • Prospective, randomized trial of Doppler-assisted subclavian vein catheterization
    • Bold R.J., Winchester D.J., Madary A.R., Gregurich M.A., and Mansfield P.F. Prospective, randomized trial of Doppler-assisted subclavian vein catheterization. Arch Surg 133 (1998) 1089-1093
    • (1998) Arch Surg , vol.133 , pp. 1089-1093
    • Bold, R.J.1    Winchester, D.J.2    Madary, A.R.3    Gregurich, M.A.4    Mansfield, P.F.5
  • 58
    • 32144451733 scopus 로고    scopus 로고
    • Comment optimiser l'utilisation des cathéters veineux centraux en réanimation ?
    • Merrer J., Lefrant J.Y., and Timsit J.F. Comment optimiser l'utilisation des cathéters veineux centraux en réanimation ?. Ann Fr Anesth Reanim 25 (2006) 180-188
    • (2006) Ann Fr Anesth Reanim , vol.25 , pp. 180-188
    • Merrer, J.1    Lefrant, J.Y.2    Timsit, J.F.3
  • 59
    • 0022618051 scopus 로고
    • Acute complications of pulmonary artery catheter insertion in critically ill patients
    • Patel C., Laboy V., Venus B., Mathru M., and Wier D. Acute complications of pulmonary artery catheter insertion in critically ill patients. Crit Care Med 14 (1986) 195-197
    • (1986) Crit Care Med , vol.14 , pp. 195-197
    • Patel, C.1    Laboy, V.2    Venus, B.3    Mathru, M.4    Wier, D.5
  • 60
    • 0021939891 scopus 로고
    • Ventricular arrhythmias during pulmonary artery catheterization in the intensive care unit. Prospective study
    • Iberti T.J., Benjamin E., Gruppi L., and Raskin J.M. Ventricular arrhythmias during pulmonary artery catheterization in the intensive care unit. Prospective study. Am J Med 78 (1985) 451-454
    • (1985) Am J Med , vol.78 , pp. 451-454
    • Iberti, T.J.1    Benjamin, E.2    Gruppi, L.3    Raskin, J.M.4
  • 61
  • 62
    • 0022556989 scopus 로고
    • A prospective analysis of 1400 pulmonary artery catheterizations in patients undergoing cardiac surgery
    • Damen J., and Bolton D. A prospective analysis of 1400 pulmonary artery catheterizations in patients undergoing cardiac surgery. Acta Anaesthesiol Scand 30 (1986) 386-392
    • (1986) Acta Anaesthesiol Scand , vol.30 , pp. 386-392
    • Damen, J.1    Bolton, D.2
  • 64
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial
    • Richard C., Warszawski J., Anguel N., Deye N., Combes A., Barnoud D., et al. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290 (2003) 2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3    Deye, N.4    Combes, A.5    Barnoud, D.6
  • 65
    • 33646264553 scopus 로고    scopus 로고
    • Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery
    • Bossert T., Gummert J.F., Bittner H.B., Barten M., Walther T., Falk V., et al. Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery. J Card Surg 21 (2006) 292-295
    • (2006) J Card Surg , vol.21 , pp. 292-295
    • Bossert, T.1    Gummert, J.F.2    Bittner, H.B.3    Barten, M.4    Walther, T.5    Falk, V.6
  • 66
    • 0021273264 scopus 로고
    • A review of pulmonary artery catheterization in 6245 patients
    • Shah K.B., Rao T.L., Laughlin S., and El-Etr A.A. A review of pulmonary artery catheterization in 6245 patients. Anesthesiology 61 (1984) 271-275
    • (1984) Anesthesiology , vol.61 , pp. 271-275
    • Shah, K.B.1    Rao, T.L.2    Laughlin, S.3    El-Etr, A.A.4
  • 67
    • 0021924627 scopus 로고
    • Catheter-induced lesions of the right side of the heart. A one-year prospective study of 141 autopsies
    • Ducatman B.S., McMichan J.C., and Edwards W.D. Catheter-induced lesions of the right side of the heart. A one-year prospective study of 141 autopsies. JAMA 253 (1985) 791-795
    • (1985) JAMA , vol.253 , pp. 791-795
    • Ducatman, B.S.1    McMichan, J.C.2    Edwards, W.D.3
  • 68
    • 0036562506 scopus 로고    scopus 로고
    • Routine daily chest radiography in patients with pulmonary artery catheters
    • Houghton D., Cohn S., Schell V., Cohn K., and Varon A. Routine daily chest radiography in patients with pulmonary artery catheters. Am J Crit Care 11 (2002) 261-265
    • (2002) Am J Crit Care , vol.11 , pp. 261-265
    • Houghton, D.1    Cohn, S.2    Schell, V.3    Cohn, K.4    Varon, A.5
  • 69
    • 0026409569 scopus 로고
    • Interobserver variability in the interpretation of pulmonary artery catheter pressure tracings
    • Komadina K.H., Schenk D.A., LaVeau P., Duncan C.A., and Chambers S.L. Interobserver variability in the interpretation of pulmonary artery catheter pressure tracings. Chest 100 (1991) 1647-1654
    • (1991) Chest , vol.100 , pp. 1647-1654
    • Komadina, K.H.1    Schenk, D.A.2    LaVeau, P.3    Duncan, C.A.4    Chambers, S.L.5
  • 70
    • 0026068619 scopus 로고
    • Estimating left ventricular filling pressure during positive end-expiratory pressure in humans
    • Pinsky M., Vincent J.L., and De Smet J.M. Estimating left ventricular filling pressure during positive end-expiratory pressure in humans. Am Rev Respir Dis 143 (1991) 25-31
    • (1991) Am Rev Respir Dis , vol.143 , pp. 25-31
    • Pinsky, M.1    Vincent, J.L.2    De Smet, J.M.3
  • 71
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F., Boussat S., Chemla D., Anguel N., Mercat A., Lecarpentier Y., et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162 (2000) 134-138
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3    Anguel, N.4    Mercat, A.5    Lecarpentier, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.