메뉴 건너뛰기




Volumn 11, Issue 3, 2002, Pages 261-265

Routine daily chest radiography in patients with pulmonary artery catheters

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CRITICAL ILLNESS; DIAGNOSTIC TEST; FEMALE; HUMAN; LUNG WEDGE PRESSURE; MALE; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; PROSPECTIVE STUDY; PULMONARY ARTERY; RADIOGRAPHY; SWAN GANZ CATHETER; TIME;

EID: 0036562506     PISSN: 10623264     EISSN: None     Source Type: Journal    
DOI: 10.4037/ajcc2002.11.3.261     Document Type: Article
Times cited : (7)

References (25)
  • 1
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283:447-451.
    • (1970) N Engl J Med. , vol.283 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3    Marcus, H.4    Diamond, G.5    Chonette, D.6
  • 2
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors AF Jr, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA. 1996;276:889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors Jr., A.F.1    Speroff, T.2    Dawson, N.V.3
  • 3
    • 0028806217 scopus 로고
    • Pulmonary artery rupture associated with the Swan-Ganz catheter
    • Kearney TJ, Shabot MM. Pulmonary artery rupture associated with the Swan-Ganz catheter. Chest. 1995;108:1349-1352.
    • (1995) Chest , vol.108 , pp. 1349-1352
    • Kearney, T.J.1    Shabot, M.M.2
  • 4
    • 0344090176 scopus 로고    scopus 로고
    • Arterial, central venous, and pulmonary artery catheters
    • Civetta JM, Taylor RW, Kirby RR, eds. Philadelphia, Pa: Lippincott-Raven
    • Varon A. Arterial, central venous, and pulmonary artery catheters. In: Civetta JM, Taylor RW, Kirby RR, eds. Critical Care. 3rd ed. Philadelphia, Pa: Lippincott-Raven; 1997:847-865.
    • (1997) Critical Care. 3rd Ed. , pp. 847-865
    • Varon, A.1
  • 5
    • 0030985463 scopus 로고    scopus 로고
    • Failure of a Swan-Ganz catheter to show a pulmonary artery wedge tracing
    • Lyew M, Peters-Koren D. Failure of a Swan-Ganz catheter to show a pulmonary artery wedge tracing. J Cardiothorac Vasc Anesth. 1997;11:801-802.
    • (1997) J Cardiothorac Vasc Anesth. , vol.11 , pp. 801-802
    • Lyew, M.1    Peters-Koren, D.2
  • 6
    • 0023448923 scopus 로고
    • Pulmonary artery false aneurysms secondary to Swan-Ganz pulmonary artery catheters
    • Dieden J, Friloux L, Renner J. Pulmonary artery false aneurysms secondary to Swan-Ganz pulmonary artery catheters. AJR Am J Roentgenol. 1987;149:901-906.
    • (1987) AJR Am J Roentgenol. , vol.149 , pp. 901-906
    • Dieden, J.1    Friloux, L.2    Renner, J.3
  • 7
    • 0025727090 scopus 로고
    • New method for monitoring pulmonary artery catheter location
    • Santora T, Ganz W, Gold J, et al. New method for monitoring pulmonary artery catheter location. Crit Care Med. 1991;19:422-426.
    • (1991) Crit Care Med. , vol.19 , pp. 422-426
    • Santora, T.1    Ganz, W.2    Gold, J.3
  • 8
    • 0032969670 scopus 로고    scopus 로고
    • A knot in the heart: Surgical removal of a pulmonary artery catheter entangled in the tricuspid valve chordae
    • Perreas K, Kumar S, Khan Z, Rees A. A knot in the heart: surgical removal of a pulmonary artery catheter entangled in the tricuspid valve chordae [letter]. Eur J Cardiothorac Surg. 1999;15:112-113.
    • (1999) Eur J Cardiothorac Surg. , vol.15 , pp. 112-113
    • Perreas, K.1    Kumar, S.2    Khan, Z.3    Rees, A.4
  • 9
    • 0025158034 scopus 로고
    • Misplacement of a Swan-Ganz catheter after insertion through the left internal jugular vein
    • Unger P, Stoupel E, Berkenboom G. Misplacement of a Swan-Ganz catheter after insertion through the left internal jugular vein. Cathet Cardiovasc Diagn. 1990;21:13-14.
    • (1990) Cathet Cardiovasc Diagn. , vol.21 , pp. 13-14
    • Unger, P.1    Stoupel, E.2    Berkenboom, G.3
  • 10
    • 0025685462 scopus 로고
    • A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group
    • Iberti TJ, Fischer EP, Leibowitz AB, Panacek EA, Silverstein JH, Albertson TE. A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA. 1990;264:2928-2932.
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3    Panacek, E.A.4    Silverstein, J.H.5    Albertson, T.E.6
  • 11
    • 0347667925 scopus 로고
    • Hemodynamic monitoring: Pulmonary artery catheters
    • Taylor RW, Civetta JM, Kirby RR, eds. Philadelphia, Pa: Lippincott-Raven
    • Clark C, Harman E. Hemodynamic monitoring: pulmonary artery catheters. In: Taylor RW, Civetta JM, Kirby RR, eds. Techniques and Procedures in Critical Care. Philadelphia, Pa: Lippincott-Raven; 1990:232-247.
    • (1990) Techniques and Procedures in Critical Care , pp. 232-247
    • Clark, C.1    Harman, E.2
  • 12
    • 0346407045 scopus 로고    scopus 로고
    • Pulmonary artery catheter insertion
    • Lynn-McHale D, Carlson K, eds. Philadelphia, Pa: WB Saunders Co
    • Fleck D. Pulmonary artery catheter insertion. In: Lynn-McHale D, Carlson K, eds. AACN Procedure Manual for Critical Care. 4th ed. Philadelphia, Pa: WB Saunders Co; 2001:431-438.
    • (2001) AACN Procedure Manual for Critical Care. 4th Ed. , pp. 431-438
    • Fleck, D.1
  • 16
    • 0142175089 scopus 로고    scopus 로고
    • Pulmonary artery catheters
    • Irwin R, Cerra F, Rippe J, eds. Philadelphia, Pa: Lippincott-Raven
    • Voyce S. Pulmonary artery catheters. In: Irwin R, Cerra F, Rippe J, eds. Intensive Care Medicine. 4th ed. Philadelphia, Pa: Lippincott-Raven; 1999:46-71.
    • (1999) Intensive Care Medicine. 4th Ed. , pp. 46-71
    • Voyce, S.1
  • 18
    • 0029031061 scopus 로고
    • Utility of routine chest radiographs in the surgical intensive care unit: A prospective study
    • Fong Y, Whalen GF, Hariri RJ, Barie PS. Utility of routine chest radiographs in the surgical intensive care unit: a prospective study. Arch Surg. 1995;130:764-768.
    • (1995) Arch Surg. , vol.130 , pp. 764-768
    • Fong, Y.1    Whalen, G.F.2    Hariri, R.J.3    Barie, P.S.4
  • 19
    • 0027374582 scopus 로고
    • The utility of routine daily chest radiography in the surgical intensive care unit
    • Silverstein DS, Livingston DH, Elcavage J, Kovar L, Kelly KM. The utility of routine daily chest radiography in the surgical intensive care unit. J Trauma. 1993;35:643-646.
    • (1993) J Trauma. , vol.35 , pp. 643-646
    • Silverstein, D.S.1    Livingston, D.H.2    Elcavage, J.3    Kovar, L.4    Kelly, K.M.5
  • 20
    • 0020019219 scopus 로고
    • The value of routine daily chest x-rays in intubated patients in the medical intensive care unit
    • Greenbaum DM, Marschall KE. The value of routine daily chest x-rays in intubated patients in the medical intensive care unit. Crit Care Med. 1982;10:29-30.
    • (1982) Crit Care Med. , vol.10 , pp. 29-30
    • Greenbaum, D.M.1    Marschall, K.E.2
  • 21
    • 0025761668 scopus 로고
    • Efficacy of daily routine chest radiographs in intubated, mechanically ventilated patients
    • Hall JB, White SR, Karrison T. Efficacy of daily routine chest radiographs in intubated, mechanically ventilated patients. Crit Care Med. 1991;19:689-693.
    • (1991) Crit Care Med. , vol.19 , pp. 689-693
    • Hall, J.B.1    White, S.R.2    Karrison, T.3
  • 23
    • 0028208653 scopus 로고
    • Catheter placement and misplacement
    • Zarshenas Z, Sparschu R. Catheter placement and misplacement. Crit Care Clin. 1994;10:417-436.
    • (1994) Crit Care Clin. , vol.10 , pp. 417-436
    • Zarshenas, Z.1    Sparschu, R.2
  • 24
    • 0032913051 scopus 로고    scopus 로고
    • A reevaluation of the radiographically detectable complications of percutaneous venous access lines inserted by four subcutaneous approaches
    • Miller JA, Singireddy S, Maldjian P, Baker SR. A reevaluation of the radiographically detectable complications of percutaneous venous access lines inserted by four subcutaneous approaches. Am Surg. 1999;65:125-130.
    • (1999) Am Surg. , vol.65 , pp. 125-130
    • Miller, J.A.1    Singireddy, S.2    Maldjian, P.3    Baker, S.R.4
  • 25
    • 0029748538 scopus 로고    scopus 로고
    • False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: Clinical presentation and radiologic management
    • Ferretti GR, Thony F, Link KM, et al. False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: clinical presentation and radiologic management. AJR Am J Roentgenol. 1996;167:941-945.
    • (1996) AJR Am J Roentgenol. , vol.167 , pp. 941-945
    • Ferretti, G.R.1    Thony, F.2    Link, K.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.