메뉴 건너뛰기




Volumn 33, Issue 19, 2008, Pages

Effect of insertional temperature on the pullout strength of pedicle screws inserted into thoracic vertebrae: An in vitro calf study

Author keywords

Microcrack; Pedicle screw; Pullout strength

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BONE SCREW; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FORCE; IN VITRO STUDY; NONHUMAN; OUTCOME ASSESSMENT; PEDICLE SCREW; PRIORITY JOURNAL; TEMPERATURE; TORQUE; VERTEBRA; ANIMAL; CATTLE; COLD; EQUIPMENT; INSTRUMENTATION; MATERIALS TESTING; MECHANICAL STRESS; METHODOLOGY; PROSTHESIS FAILURE; SPINE FUSION;

EID: 55449138414     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31817c4f9c     Document Type: Article
Times cited : (3)

References (38)
  • 1
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdeblik TA. A prospective, randomized study of lumbar fusion. Preliminary results. Spine 1993;18:983-91.
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblik, T.A.1
  • 2
    • 0033998139 scopus 로고    scopus 로고
    • Can insertional torque predict screw loosening and. related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion
    • Okuyama K, Abe E, Suzuki T, et al. Can insertional torque predict screw loosening and. related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. Spine 2000;25:858-64.
    • (2000) Spine , vol.25 , pp. 858-864
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3
  • 3
    • 21844480606 scopus 로고    scopus 로고
    • Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses
    • Hsu CC, Chao CK, Wang JL, et al. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 2004;23:788-94.
    • (2004) J Orthop Res , vol.23 , pp. 788-794
    • Hsu, C.C.1    Chao, C.K.2    Wang, J.L.3
  • 4
    • 0026777874 scopus 로고
    • Complications of lumbar spinal fusion with transpe-dicular instrumentation
    • Davne SH, Myers DL. Complications of lumbar spinal fusion with transpe-dicular instrumentation. Spine 1992;17:S184-S189.
    • (1992) Spine , vol.17
    • Davne, S.H.1    Myers, D.L.2
  • 5
    • 0027509721 scopus 로고
    • Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report
    • McLain RF, Sparling E, Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am 1993;75:162-7.
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 162-167
    • McLain, R.F.1    Sparling, E.2    Benson, D.R.3
  • 6
    • 0028600649 scopus 로고
    • Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases
    • Ohlin A, Karlsson M, Duppe H, et al. Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine 1994; 19:2774-9.
    • (1994) Spine , vol.19 , pp. 2774-2779
    • Ohlin, A.1    Karlsson, M.2    Duppe, H.3
  • 7
    • 0027143864 scopus 로고
    • Spondylodesis augmented by transpedicular fixation in the treatment of olisthetic and degenerative conditions of the lumbar spine
    • Soini J, Laine T, Pohjolainen T, et al. Spondylodesis augmented by transpedicular fixation in the treatment of olisthetic and degenerative conditions of the lumbar spine. Clin Orthop 1993;297:111-6.
    • (1993) Clin Orthop , vol.297 , pp. 111-116
    • Soini, J.1    Laine, T.2    Pohjolainen, T.3
  • 8
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
    • discussion 2238-9
    • Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 1993;18: 2231-8; discussion 2238-9.
    • (1993) Spine , vol.18 , pp. 2231-2238
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 9
    • 4844227313 scopus 로고    scopus 로고
    • Stress relaxation of bone significantly affects the pull-out behaviour of pedicle screws
    • Inceoglu S, McLain RF, Cayli S, et al. Stress relaxation of bone significantly affects the pull-out behaviour of pedicle screws. J Orthop Res 2004;22: 1243-7.
    • (2004) J Orthop Res , vol.22 , pp. 1243-1247
    • Inceoglu, S.1    McLain, R.F.2    Cayli, S.3
  • 10
    • 0032526351 scopus 로고    scopus 로고
    • Revision pedicle screws. Bigger, longer shims-what is best?
    • Polly DW, Orchowski JR, Ellenbogen RG. Revision pedicle screws. Bigger, longer shims-what is best? Spine 1998;23:1374-9.
    • (1998) Spine , vol.23 , pp. 1374-1379
    • Polly, D.W.1    Orchowski, J.R.2    Ellenbogen, R.G.3
  • 11
    • 0022628372 scopus 로고
    • A biomechanical study of inter-peduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of inter-peduncular screw fixation in the lumbosacral spine. Clin Orthop 1986;203: 99-112.
    • (1986) Clin Orthop , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3
  • 12
    • 0038725012 scopus 로고    scopus 로고
    • A biomechanical study of the cortex-anchorage vertebral screw
    • Lin LC, Chen HH, Sun SP. A biomechanical study of the cortex-anchorage vertebral screw. Clin Biomech 2003;18:S25-S32.
    • (2003) Clin Biomech , vol.18
    • Lin, L.C.1    Chen, H.H.2    Sun, S.P.3
  • 13
    • 33644878439 scopus 로고    scopus 로고
    • Evaluation of cyanoacrylate augmentation of transpedicular pullout strength
    • Milcan A, Ayan I, Zeren A, et al. Evaluation of cyanoacrylate augmentation of transpedicular pullout strength. J Spinal Disord Tech 2005;18:511-4.
    • (2005) J Spinal Disord Tech , vol.18 , pp. 511-514
    • Milcan, A.1    Ayan, I.2    Zeren, A.3
  • 14
    • 0141478986 scopus 로고    scopus 로고
    • Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: A biomechanical analysis
    • Lehman RA Jr, Polly DW Jr, Kuklo TR, et al. Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: a biomechanical analysis. Spine 2003;28:2058-65.
    • (2003) Spine , vol.28 , pp. 2058-2065
    • Lehman Jr, R.A.1    Polly Jr, D.W.2    Kuklo, T.R.3
  • 15
    • 0035884966 scopus 로고    scopus 로고
    • Thoracic pedicle screw fixation in spinal deformities. Are they really safe?
    • Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities. Are they really safe? Spine 2001;26:2049-57.
    • (2001) Spine , vol.26 , pp. 2049-2057
    • Suk, S.I.1    Kim, W.J.2    Lee, S.M.3
  • 16
    • 0035851762 scopus 로고    scopus 로고
    • Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out
    • Abshire BB, McLain RF, Valdevit A, et al. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Spine J 2001;l:408-14.
    • (2001) Spine J , vol.50 , pp. 408-414
    • Abshire, B.B.1    McLain, R.F.2    Valdevit, A.3
  • 17
    • 0034888612 scopus 로고    scopus 로고
    • Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws
    • Ono A, Brown MD, Lata LL, et al. Triangulated pedicle screw construct technique and pull-out strength of conical and cylindrical screws. J Spinal Disdord 2001;14:323-29.
    • (2001) J Spinal Disdord , vol.14 , pp. 323-329
    • Ono, A.1    Brown, M.D.2    Lata, L.L.3
  • 18
    • 0028331088 scopus 로고
    • Hydroxyapatite enhancement of posterior spinal instrumentation fixation
    • Spivak JM, Neuwirth MG, Labiak JJ, et al. Hydroxyapatite enhancement of posterior spinal instrumentation fixation. Spine 1994;19:955-64.
    • (1994) Spine , vol.19 , pp. 955-964
    • Spivak, J.M.1    Neuwirth, M.G.2    Labiak, J.J.3
  • 19
    • 0033830766 scopus 로고    scopus 로고
    • Titanium-alloy enhances bone-pedicle screw fixation: Mechanical and histomorphometrical results of titanium-alloy versus stainless steel
    • Christensen FB, Dalstra M, Sejling F, et al. Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel. Eur Spine J 2000;9:97-103.
    • (2000) Eur Spine J , vol.9 , pp. 97-103
    • Christensen, F.B.1    Dalstra, M.2    Sejling, F.3
  • 20
    • 0027203876 scopus 로고
    • Pedicle screw pullout strength. Correlation with insertional torque
    • Zdeblick TA, Kunz DN, Cooke ME, et al. Pedicle screw pullout strength. Correlation with insertional torque. Spine 1993;18:1673-6.
    • (1993) Spine , vol.18 , pp. 1673-1676
    • Zdeblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3
  • 21
    • 0028258268 scopus 로고
    • Correlations between screw hole penetration, torque of insertion and pullout strength for spinal screws
    • Daftari TK, Horton WC, Hutton WC. Correlations between screw hole penetration, torque of insertion and pullout strength for spinal screws. J Spinal Disord 1994;7:139-45.
    • (1994) J Spinal Disord , vol.7 , pp. 139-145
    • Daftari, T.K.1    Horton, W.C.2    Hutton, W.C.3
  • 22
    • 0034464574 scopus 로고    scopus 로고
    • Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180 degrees
    • Lill CA, Schlegel U, Wahl D, et al. Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180 degrees. J Spinal Disord 2000;13:259-66.
    • (2000) J Spinal Disord , vol.13 , pp. 259-266
    • Lill, C.A.1    Schlegel, U.2    Wahl, D.3
  • 23
    • 0025351033 scopus 로고
    • Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study
    • Skinner R, Maybee J, Transfeldt E, et al. Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 1990;15:195-201.
    • (1990) Spine , vol.15 , pp. 195-201
    • Skinner, R.1    Maybee, J.2    Transfeldt, E.3
  • 24
    • 0028819606 scopus 로고
    • Lumbar pedicle screw salvage: Pullout testing of three different pedicle screw designs
    • McLain RF, Fry MF, Moseley TA, et al. Lumbar pedicle screw salvage: pullout testing of three different pedicle screw designs. J Spinal Disord 1995; 8:62-8.
    • (1995) J Spinal Disord , vol.8 , pp. 62-68
    • McLain, R.F.1    Fry, M.F.2    Moseley, T.A.3
  • 25
    • 0141813640 scopus 로고    scopus 로고
    • Effect of various tapping diameters on insertion of thoracic pedicle screws: A biomechanical analysis
    • Kuklo TR, Lehman RA Jr. Effect of various tapping diameters on insertion of thoracic pedicle screws: a biomechanical analysis. Spine 2003;28:2066-71.
    • (2003) Spine , vol.28 , pp. 2066-2071
    • Kuklo, T.R.1    Lehman Jr., R.A.2
  • 26
    • 0030221045 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of cancellous bone screws
    • Chapman JR, Harrington RM, Lee KM, et al. Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 1996;118:391-98.
    • (1996) J Biomech Eng , vol.118 , pp. 391-398
    • Chapman, J.R.1    Harrington, R.M.2    Lee, K.M.3
  • 27
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991; 16:1335-41.
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3
  • 28
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thracolumbar implants: A comperative study of transpedicular screws, laminar hooks, and spinous process wires
    • Coe JD, Warden KE, Herzig MA, et al. Influence of bone mineral density on the fixation of thracolumbar implants: a comperative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 1990;15:902-7.
    • (1990) Spine , vol.15 , pp. 902-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3
  • 29
    • 0026505213 scopus 로고
    • Mechanical stability of the pedicle screw systems for the lumbar spine
    • Yagamata M, Kitahara H, Minami S, et al. Mechanical stability of the pedicle screw systems for the lumbar spine. Spine 1992;17(Suppl):S51-S54.
    • (1992) Spine , vol.17 , Issue.SUPPL.
    • Yagamata, M.1    Kitahara, H.2    Minami, S.3
  • 30
    • 0031419970 scopus 로고    scopus 로고
    • Structural characteristics of the pedicle and its role in screw stability
    • Hirano T, Hasegawa K, Takahashi HE, et al. Structural characteristics of the pedicle and its role in screw stability. Spine 1997;22:2504-9.
    • (1997) Spine , vol.22 , pp. 2504-2509
    • Hirano, T.1    Hasegawa, K.2    Takahashi, H.E.3
  • 31
    • 0023026559 scopus 로고
    • An anatomical comparison of the human and bovine thracolumbar spine
    • Cotterill PC, Kostuik JP, D'Angelo G et al. An anatomical comparison of the human and bovine thracolumbar spine. J Orthop Res 1986;4:298-303.
    • (1986) J Orthop Res , vol.4 , pp. 298-303
    • Cotterill, P.C.1    Kostuik, J.P.2    D'Angelo, G.3
  • 32
    • 0026015142 scopus 로고
    • Pitfalls of biomechanical testings
    • Kostuik JP, Smith TJ. Pitfalls of biomechanical testings. Spine 1991;16: 1233-35.
    • (1991) Spine , vol.16 , pp. 1233-1235
    • Kostuik, J.P.1    Smith, T.J.2
  • 33
    • 1142298460 scopus 로고    scopus 로고
    • Multiaxial pedicle screw designs: Static and dynamic mechanical testing
    • Stanford RE, Loefler AH, Stanford PM, et al. Multiaxial pedicle screw designs: static and dynamic mechanical testing. Spine 2004;29:367-75.
    • (2004) Spine , vol.29 , pp. 367-375
    • Stanford, R.E.1    Loefler, A.H.2    Stanford, P.M.3
  • 34
    • 0028131949 scopus 로고
    • The case of pedicle fixation of the lumbar spine
    • Ransom N, LA Rocca SH, Thalgott J. The case of pedicle fixation of the lumbar spine. Spine 1994;19:2702-6.
    • (1994) Spine , vol.19 , pp. 2702-2706
    • Ransom, N.1    LA Rocca, S.H.2    Thalgott, J.3
  • 35
    • 0018143482 scopus 로고
    • The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface
    • Halawa M, Lee AC, Ling RM, et al. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg 1978;92:19-30.
    • (1978) Arch Orthop Trauma Surg , vol.92 , pp. 19-30
    • Halawa, M.1    Lee, A.C.2    Ling, R.M.3
  • 36
    • 33750542318 scopus 로고    scopus 로고
    • A comparison of pullout strength for pedicle screws of different designs
    • Pfeiffer FM, Abernathie DL. A comparison of pullout strength for pedicle screws of different designs. Spine 2006;3 l:E867-E870.
    • (2006) Spine , vol.3 , Issue.L
    • Pfeiffer, F.M.1    Abernathie, D.L.2
  • 37
    • 0033082890 scopus 로고    scopus 로고
    • Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine: In vitro comparison with two established internal fixation systems
    • Richter M, Wilke HJ, Kluger P, et al. Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine: in vitro comparison with two established internal fixation systems. Spine 1999;24:207-12.
    • (1999) Spine , vol.24 , pp. 207-212
    • Richter, M.1    Wilke, H.J.2    Kluger, P.3
  • 38
    • 0034463634 scopus 로고    scopus 로고
    • Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    • Stephen DC, Salkeld SL, Whitecloud TS III, et al. Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 2000;13:230-36.
    • (2000) J Spinal Disord , vol.13 , pp. 230-236
    • Stephen, D.C.1    Salkeld, S.L.2    Whitecloud III, T.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.