메뉴 건너뛰기




Volumn 79, Issue 2, 2008, Pages 140-143

Interference by heterophilic antibodies in immunoassays: Wrong increase of myoglobin values

Author keywords

Blocking tube; Heterophilic antibodies; Immunoassays; Myoglobin values

Indexed keywords

HETEROPHILE ANTIBODY; MYOGLOBIN;

EID: 55249120186     PISSN: 03924203     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (9)
  • 1
    • 0034716473 scopus 로고    scopus 로고
    • False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations
    • Rotmensh S, Cole LA. False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations. Lancet 2000; 355: 712-5.
    • (2000) Lancet , vol.355 , pp. 712-715
    • Rotmensh, S.1    Cole, L.A.2
  • 2
    • 0031710957 scopus 로고    scopus 로고
    • False increase of cardiac Troponin I with heterophilic antibodies
    • Fitzmaurice TF, Brown C, Rifai N, Wu AHB, Yeo KJ. False increase of cardiac Troponin I with heterophilic antibodies. Clin Chem 1998; 44: 2212-4.
    • (1998) Clin Chem , vol.44 , pp. 2212-2214
    • Fitzmaurice, T.F.1    Brown, C.2    Rifai, N.3    Wu, A.H.B.4    Yeo, K.J.5
  • 3
    • 0033032667 scopus 로고    scopus 로고
    • False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma
    • Cole LA, Rinne KM, Shahabi S, Omrani A. False-positive hCG assay results leading to unnecessary surgery and chemotherapy and needless occurrences of diabetes and coma. Clin Chem 1999; 45: 313-4.
    • (1999) Clin Chem , vol.45 , pp. 313-314
    • Cole, L.A.1    Rinne, K.M.2    Shahabi, S.3    Omrani, A.4
  • 4
    • 0023853204 scopus 로고
    • Heterophilic antibodies: A problem for all immunoassays
    • Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. Clin Chem 1988; 34: 27-33.
    • (1988) Clin Chem , vol.34 , pp. 27-33
    • Boscato, L.M.1    Stuart, M.C.2
  • 5
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka LJ. Human anti-animal antibody interferences in immunological assays. Clin Chem 1999; 45: 942-56.
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 6
    • 0036844469 scopus 로고    scopus 로고
    • Toward a better understanding of heterophile (and the like) antibody interference with modern immunoassays
    • Levinson SS, Miller JJ. Toward a better understanding of heterophile (and the like) antibody interference with modern immunoassays. Clin Chem Acta 2002; 325: 1-5.
    • (2002) Clin Chem Acta , vol.325 , pp. 1-5
    • Levinson, S.S.1    Miller, J.J.2
  • 7
    • 0036839769 scopus 로고    scopus 로고
    • False-positive immunoassay results: A multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries
    • Marks V. False-positive immunoassay results: a multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries. Clin Chem 2002; 48: 2008-16.
    • (2002) Clin Chem , vol.48 , pp. 2008-2016
    • Marks, V.1
  • 8
    • 0034961220 scopus 로고    scopus 로고
    • Use of heterophilic antibody blocking agent (HBT) in reducing false-positive hCG results
    • Butler SA, Cole LA. Use of heterophilic antibody blocking agent (HBT) in reducing false-positive hCG results. Clin Chem 2001; 47: 1332-33.
    • (2001) Clin Chem , vol.47 , pp. 1332-1333
    • Butler, S.A.1    Cole, L.A.2
  • 9
    • 0030765913 scopus 로고    scopus 로고
    • Heterophilic antibodies remain a problem for the immunoassay laboratory
    • Ward G, McKinnon L, Baldrick T, Hickman PE. Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Pathol 1997; 108: 417-21.
    • (1997) Am J Clin Pathol , vol.108 , pp. 417-421
    • Ward, G.1    McKinnon, L.2    Baldrick, T.3    Hickman, P.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.