메뉴 건너뛰기




Volumn 129, Issue 1-3, 2008, Pages 119-122

A pixel detector-based single photon-counting system as fast spectrometer for diagnostic x-ray beams

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DIGITAL IMAGING; DIGITAL RADIOGRAPHY; IMAGE QUALITY; RADIATION DETECTION; RADIATION DETECTOR; RADIOLOGICAL PARAMETERS; SEMICONDUCTOR; SIGNAL NOISE RATIO; SINGLE PHOTON COUNTING SYSTEM; SPECTROMETER; X RAY ANALYSIS; X RAY TUBE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; HUMAN; IMAGE ENHANCEMENT; IMAGE PROCESSING; INSTRUMENTATION; METHODOLOGY; PHOTON; RADIOMETRY;

EID: 55249114890     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncn147     Document Type: Article
Times cited : (5)

References (7)
  • 1
    • 0035996550 scopus 로고    scopus 로고
    • CdZnTe detector in diagnostic X-ray spectroscopy
    • Miyajima, S., Imagawa, K. and Matsumoto, M. CdZnTe detector in diagnostic X-ray spectroscopy. Med. Phys., 29(7), 1421-1429 (2002).
    • (2002) Med. Phys , vol.29 , Issue.7 , pp. 1421-1429
    • Miyajima, S.1    Imagawa, K.2    Matsumoto, M.3
  • 2
    • 21144432095 scopus 로고    scopus 로고
    • Compton-scattering measurement of diagnostic X-ray spectrum using high-resolution Schottky CdTe detector
    • Maeda, K., Matsumoto, M. and Taniguchi, A. Compton-scattering measurement of diagnostic X-ray spectrum using high-resolution Schottky CdTe detector. Med. Phys., 32(6), 1542-1547 (2005).
    • (2005) Med. Phys , vol.32 , Issue.6 , pp. 1542-1547
    • Maeda, K.1    Matsumoto, M.2    Taniguchi, A.3
  • 3
    • 0036815755 scopus 로고    scopus 로고
    • Medipix2, a 64k pixel readout chip with 55 μm square elements working in single photon counting mode
    • Llopart, X., Campbell, M., San Secundo, D. and Pernigotti, E. Medipix2, a 64k pixel readout chip with 55 μm square elements working in single photon counting mode. IEEE Trans. Nucl. Sci., 49, 2279-2283 (2002).
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , pp. 2279-2283
    • Llopart, X.1    Campbell, M.2    San Secundo, D.3    Pernigotti, E.4
  • 7
    • 0024955812 scopus 로고
    • Measurements. Medical X-ray, electron beam and gamma ray protection for energies up to 50MeV (equipment design, performance and use)
    • NCRP, National Council on Radiation Protection and, No 102
    • NCRP, National Council on Radiation Protection and Measurements. Medical X-ray, electron beam and gamma ray protection for energies up to 50MeV (equipment design, performance and use). NCRP Report No 102, 34 (1989).
    • (1989) NCRP Report , vol.34


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.