메뉴 건너뛰기




Volumn 195, Issue 2, 2008, Pages 129-133

Detection of 3He spins with ultra-low field nuclear magnetic resonance employing SQUIDs for application to a neutron electric dipole moment experiment

Author keywords

Electric dipole moment; Helium; Neutron; SQUID; Ultra low field

Indexed keywords

CRUDE PETROLEUM; DIPOLE MOMENT; HELIUM; INERT GASES; MAGNETIC RESONANCE; NEUTRONS; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; RESONANCE; SPIN DYNAMICS; SQUIDS;

EID: 55049089581     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2008.09.008     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 33749177922 scopus 로고    scopus 로고
    • Improved experimental limit on the electric dipole moment of the neutron
    • 131801/1-131801/4
    • Baker C.A., et al. Improved experimental limit on the electric dipole moment of the neutron. Phys. Rev. Lett. 97 (2006) 131801/1-131801/4
    • (2006) Phys. Rev. Lett. , vol.97
    • Baker, C.A.1
  • 3
    • 4243051462 scopus 로고    scopus 로고
    • SQUID detected NMR in microtesla fields
    • Matlachov A., et al. SQUID detected NMR in microtesla fields. J. Magn. Reson. 170 (2004) 1
    • (2004) J. Magn. Reson. , vol.170 , pp. 1
    • Matlachov, A.1
  • 4
    • 36048980917 scopus 로고    scopus 로고
    • Toward direct neural current imaging by resonant mechanisms at ultra-low field
    • Kraus R., et al. Toward direct neural current imaging by resonant mechanisms at ultra-low field. Neuroimage 39 (2008) 1
    • (2008) Neuroimage , vol.39 , pp. 1
    • Kraus, R.1
  • 5
    • 33750616681 scopus 로고    scopus 로고
    • Ultra-low field NMR measurements of liquids and gases with short relaxation times
    • Volegov P., et al. Ultra-low field NMR measurements of liquids and gases with short relaxation times. J. Magn. Res. 183 1 (2006)
    • (2006) J. Magn. Res. , vol.183 , Issue.1
    • Volegov, P.1
  • 6
    • 43949130420 scopus 로고    scopus 로고
    • Parallel MRI at microtesla fields
    • Zotev V., et al. Parallel MRI at microtesla fields. J. Magn. Reson. 192 (2008) 197-208
    • (2008) J. Magn. Reson. , vol.192 , pp. 197-208
    • Zotev, V.1
  • 7
    • 0037155596 scopus 로고    scopus 로고
    • Liquid-state NMR and scalar couplings in microtesla magnetic fields
    • McDermott R., et al. Liquid-state NMR and scalar couplings in microtesla magnetic fields. Science 295 (2002) 5563
    • (2002) Science , vol.295 , pp. 5563
    • McDermott, R.1
  • 8
    • 49549133678 scopus 로고
    • The signal-to-noise of the nuclear magnetic resonance experiment
    • Hoult D.I., and Richard R.E. The signal-to-noise of the nuclear magnetic resonance experiment. J. Magn. Reson. 24 (1976) 71-85
    • (1976) J. Magn. Reson. , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richard, R.E.2
  • 9
    • 35348825462 scopus 로고    scopus 로고
    • SQUID-detected magnetic resonance imaging in microtesla fields
    • Clarke J., Hatridge M., and Mößle M. SQUID-detected magnetic resonance imaging in microtesla fields. Annu. Rev. Biomed. Eng. 9 (2007) 389-413
    • (2007) Annu. Rev. Biomed. Eng. , vol.9 , pp. 389-413
    • Clarke, J.1    Hatridge, M.2    Mößle, M.3
  • 10
    • 0036498345 scopus 로고    scopus 로고
    • The temperature dependence of SQUID noise at temperatures below 4 K
    • Espy M., et al. The temperature dependence of SQUID noise at temperatures below 4 K. Physica C 368 (2002) 1-4
    • (2002) Physica C , vol.368 , pp. 1-4
    • Espy, M.1
  • 11
    • 0029492590 scopus 로고
    • Minimum variance of frequency estimations for a sinusoidal signal with low noise
    • Chibane Y., Lamoreaux S.K., Pendlebury J.M., and Smith K.F. Minimum variance of frequency estimations for a sinusoidal signal with low noise. Meas. Sci. Technol. 6 (1995) 1671
    • (1995) Meas. Sci. Technol. , vol.6 , pp. 1671
    • Chibane, Y.1    Lamoreaux, S.K.2    Pendlebury, J.M.3    Smith, K.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.