메뉴 건너뛰기




Volumn , Issue , 2008, Pages

Stator faults detection based on the dq0 voltage components

Author keywords

Condition monitoring; Dq0 components; Fault detection; Induction motor; Stator fault

Indexed keywords

AC MOTORS; CONDITION MONITORING; FAULT DETECTION; MOTORS; STATORS;

EID: 54549105889     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICIT.2008.4608400     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 29244467991 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical motors-a review
    • Dec
    • S. Nandi, H.A. Toliyat, and X. Li, "Condition monitoring and fault diagnosis of electrical motors-a review," IEEE Trans. on Energy Conversion, vol. 20, no. 4, pp. 719-729, Dec. 2005.
    • (2005) IEEE Trans. on Energy Conversion , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 2
    • 0026886680 scopus 로고
    • Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
    • Jul./Aug
    • A.H. Bonnett, and G.C. Soukup, "Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors," IEEE Trans. on Industry Applications, vol. 28, no. 4, pp. 921-937, Jul./Aug. 1992.
    • (1992) IEEE Trans. on Industry Applications , vol.28 , Issue.4 , pp. 921-937
    • Bonnett, A.H.1    Soukup, G.C.2
  • 3
    • 29244436133 scopus 로고    scopus 로고
    • An online technique for monitoring the insulation condition of ac machine stator windings
    • Dec
    • S.B. Lee, K. Younsi, and G.B. Kliman, "An online technique for monitoring the insulation condition of ac machine stator windings," IEEE Trans. on Energy Conversion, vol. 20, no. 4, pp. 737-745, Dec. 2005.
    • (2005) IEEE Trans. on Energy Conversion , vol.20 , Issue.4 , pp. 737-745
    • Lee, S.B.1    Younsi, K.2    Kliman, G.B.3
  • 4
    • 0036245419 scopus 로고    scopus 로고
    • Novel frequency-domain-based technique to detect stator inter-turn faults in induction machines using stator-induced voltage after switch-off
    • Jan./Feb
    • S. Nandi, and H.A. Toliyat, "Novel frequency-domain-based technique to detect stator inter-turn faults in induction machines using stator-induced voltage after switch-off," IEEE Trans. on Industry Applications, vol. 38, no. 1, pp. 101-109, Jan./Feb. 2002.
    • (2002) IEEE Trans. on Industry Applications , vol.38 , Issue.1 , pp. 101-109
    • Nandi, S.1    Toliyat, H.A.2
  • 5
    • 0344443880 scopus 로고    scopus 로고
    • Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system
    • Dec
    • F. Zidani, M.E.H. Benbouzid, D. Diallo, and M.S. Nait-Said, "Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system," IEEE Trans. on Energy Conversion, vol. 18, no. 4, pp. 469-475, Dec. 2003.
    • (2003) IEEE Trans. on Energy Conversion , vol.18 , Issue.4 , pp. 469-475
    • Zidani, F.1    Benbouzid, M.E.H.2    Diallo, D.3    Nait-Said, M.S.4
  • 7
    • 0032205939 scopus 로고    scopus 로고
    • Insulation failure prediction in AC machines using line-neutral voltages
    • Nov./Dec
    • M.A. Cash, T.G. Habetler, and G.B. Kliman, "Insulation failure prediction in AC machines using line-neutral voltages," IEEE Trans. on Industry Applications, vol. 34, no. 6, pp. 1234-1239, Nov./Dec. 1998.
    • (1998) IEEE Trans. on Industry Applications , vol.34 , Issue.6 , pp. 1234-1239
    • Cash, M.A.1    Habetler, T.G.2    Kliman, G.B.3
  • 8
    • 29244478009 scopus 로고    scopus 로고
    • Mechanical fault detection in a medium-sized induction motor using stator current monitoring
    • Dec
    • A.M. Knight, and S.P. Bertani, "Mechanical fault detection in a medium-sized induction motor using stator current monitoring," IEEE Trans. on Energy Conversion, vol. 20, no. 4, pp. 753-760, Dec. 2005.
    • (2005) IEEE Trans. on Energy Conversion , vol.20 , Issue.4 , pp. 753-760
    • Knight, A.M.1    Bertani, S.P.2
  • 9
  • 11
    • 0038137246 scopus 로고    scopus 로고
    • Experimental investigation on induction machine condition monitoring and fault diagnosis using digital signal processing techniques
    • S.A.S.A. Kazzaz, and G.K. Singh, "Experimental investigation on induction machine condition monitoring and fault diagnosis using digital signal processing techniques," Electric Power Systems Research, vol. 65, pp. 197-221, 2003.
    • (2003) Electric Power Systems Research , vol.65 , pp. 197-221
    • Kazzaz, S.A.S.A.1    Singh, G.K.2
  • 12
    • 0035304023 scopus 로고    scopus 로고
    • The optimization of spectral analysis for signal harmonics
    • T.P. Tsao, R.C. Wu, and C.C. Ning, "The optimization of spectral analysis for signal harmonics, IEEE Trans. on Power Delivery, vol. 16, no. 2, pp. 149-153, 2001.
    • (2001) IEEE Trans. on Power Delivery , vol.16 , Issue.2 , pp. 149-153
    • Tsao, T.P.1    Wu, R.C.2    Ning, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.