메뉴 건너뛰기




Volumn 15, Issue 1, 2007, Pages 31-46

Micromovements at the implant-abutment interface: Measurement, causes, and consequences;Erfassung, ursachen und folgen von Mikrobewegungen am implantat-abutment-interface

Author keywords

Conical connections; Implant abutment connections; Irreversible connections; Masticatory load; Masticatory simulator; Micromovements; Reversible connections

Indexed keywords


EID: 54249124385     PISSN: 09439692     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (96)

References (18)
  • 1
    • 0346219407 scopus 로고    scopus 로고
    • Single implant-supported molar and premolar crowns: A ten-year retrospective clinical report
    • Simon RL. Single implant-supported molar and premolar crowns: A ten-year retrospective clinical report. J Prosthet Dent 2003;90(6):517-521.
    • (2003) J Prosthet Dent , vol.90 , Issue.6 , pp. 517-521
    • Simon, R.L.1
  • 2
    • 0035375020 scopus 로고    scopus 로고
    • Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants
    • Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent 2001;85(6):599-607.
    • (2001) J Prosthet Dent , vol.85 , Issue.6 , pp. 599-607
    • Hoyer, S.A.1    Stanford, C.M.2    Buranadham, S.3    Fridrich, T.4    Wagner, J.5    Gratton, D.6
  • 3
    • 0034782965 scopus 로고    scopus 로고
    • Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    • Hermann JS, Schoolfield JD, Schenk RK, Buser D, Cochran DL. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. J Periodontol 2001;72(10):1372-1383.
    • (2001) J Periodontol , vol.72 , Issue.10 , pp. 1372-1383
    • Hermann, J.S.1    Schoolfield, J.D.2    Schenk, R.K.3    Buser, D.4    Cochran, D.L.5
  • 5
    • 30844441210 scopus 로고    scopus 로고
    • Tissue-directed placement of dental implants in the esthetic zone for long-term biologic synergy: A clinical report
    • Kinsel RP, Lamb RE. Tissue-directed placement of dental implants in the esthetic zone for long-term biologic synergy: A clinical report. Int J Oral Maxillofac Implants 2005;20(6): 913-922.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , Issue.6 , pp. 913-922
    • Kinsel, R.P.1    Lamb, R.E.2
  • 6
    • 0035553242 scopus 로고    scopus 로고
    • The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations
    • Bakaeen LG, Winkler S, Neff PA. The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations. J Oral Implantol 2001;27(2):63-72.
    • (2001) J Oral Implantol , vol.27 , Issue.2 , pp. 63-72
    • Bakaeen, L.G.1    Winkler, S.2    Neff, P.A.3
  • 7
    • 85018325554 scopus 로고    scopus 로고
    • Dynamische Ermüdungsprüfung für enossale dentale Implantate
    • DIN EN ISO 14801:09
    • Dynamische Ermüdungsprüfung für enossale dentale Implantate. DIN EN ISO 14801:2006-09.
    • (2006)
  • 8
    • 0141993787 scopus 로고    scopus 로고
    • In vivo forces on implants influenced by occlusal scheme and food consistency
    • Morneburg TR, Proschel PA. In vivo forces on implants influenced by occlusal scheme and food consistency. Int J Prosthodont 2003;16(5):481-486.
    • (2003) Int J Prosthodont , vol.16 , Issue.5 , pp. 481-486
    • Morneburg, T.R.1    Proschel, P.A.2
  • 9
    • 54249137582 scopus 로고    scopus 로고
    • Failure mode of implant-abutment connections after horizontal cyclic loading
    • Poster 238.
    • Zipprich H. Failure mode of implant-abutment connections after horizontal cyclic loading. Int Poster J Dent Oral Med 2004;6(No 03):Poster 238.
    • (2004) Int Poster J Dent Oral Med , vol.6 , Issue.3
    • Zipprich, H.1
  • 11
    • 33748695497 scopus 로고    scopus 로고
    • Bacterial plaque colonization around dental implant surfaces
    • Covani U, Marconcini S, Crespi R, Barone A. Bacterial plaque colonization around dental implant surfaces. Implant Dent 2006;15(3):298-304.
    • (2006) Implant Dent , vol.15 , Issue.3 , pp. 298-304
    • Covani, U.1    Marconcini, S.2    Crespi, R.3    Barone, A.4
  • 12
    • 27544507238 scopus 로고    scopus 로고
    • In vitro evaluation of the implant-abutment bacterial seal: The locking taper system
    • Dibart S, Warbington M, Su MF, Skobe Z. In vitro evaluation of the implant-abutment bacterial seal: The locking taper system. Int J Oral Maxillofac Implants 2005;20(5):732-737.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , Issue.5 , pp. 732-737
    • Dibart, S.1    Warbington, M.2    Su, M.F.3    Skobe, Z.4
  • 13
    • 20744446270 scopus 로고    scopus 로고
    • Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study
    • Renouard F, Nisand D. Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study. Clin Implant Dent Relat Res 2005;7(Suppl. 1):S104-110.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. S104-110
    • Renouard, F.1    Nisand, D.2
  • 14
    • 3242892644 scopus 로고    scopus 로고
    • Functional and esthetic considerations for single-tooth Ankylos implant-crowns: 8 years of clinical performance
    • Doring K, Eisenmann E, Stiller M. Functional and esthetic considerations for single-tooth Ankylos implant-crowns: 8 years of clinical performance. J Oral Implantol 2004;30(3): 198-209.
    • (2004) J Oral Implantol , vol.30 , Issue.3 , pp. 198-209
    • Doring, K.1    Eisenmann, E.2    Stiller, M.3
  • 17
    • 84856302217 scopus 로고    scopus 로고
    • Zehnjahresresultate mit dem Astra-Tech-Implantatsystem
    • Schulda C, Steveling H. Zehnjahresresultate mit dem Astra-Tech-Implantatsystem. Implantologie 2006;14(1):81-92.
    • (2006) Implantologie , vol.14 , Issue.1 , pp. 81-92
    • Schulda, C.1    Steveling, H.2
  • 18
    • 31944431959 scopus 로고    scopus 로고
    • Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels
    • Lazzara RJ, Porter SS. Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26(1):9-17.
    • (2006) Int J Periodontics Restorative Dent , vol.26 , Issue.1 , pp. 9-17
    • Lazzara, R.J.1    Porter, S.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.