-
3
-
-
0016630468
-
In vivo evaluation of microcirculation by coherent light scattering
-
M. D. Stern, "In vivo evaluation of microcirculation by coherent light scattering." Nature (London) 254, 56-58 (1975).
-
(1975)
Nature (London)
, vol.254
, pp. 56-58
-
-
Stern, M.D.1
-
4
-
-
0017733080
-
Laser Doppler measurement of cutaneous blood flow
-
G. A. Holloway and D. W. Watkins, "Laser Doppler measurement of cutaneous blood flow," J. Invest. Dermatol. 69, 306-309 (1977).
-
(1977)
J. Invest. Dermatol
, vol.69
, pp. 306-309
-
-
Holloway, G.A.1
Watkins, D.W.2
-
5
-
-
0019225916
-
Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow
-
G. E. Nilsson, T. Tenland, and P. A. Oberg, "Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow," IEEE Trans. Bio-Med. Electron. BME-27, 597-604 (1980).
-
(1980)
IEEE Trans. Bio-Med. Electron
, vol.BME-27
, pp. 597-604
-
-
Nilsson, G.E.1
Tenland, T.2
Oberg, P.A.3
-
6
-
-
0030873275
-
Laser Doppler evaluation of burned hands predicts need for surgical grafting
-
W. R. Schiller, R. L. Garren, R. C. Bay, M. H. Ruddell, G. A. Holloway, A. Mohty, and C. A. Luekens, "Laser Doppler evaluation of burned hands predicts need for surgical grafting," J. Trauma 43(1), 35-39 (1997).
-
(1997)
J. Trauma
, vol.43
, Issue.1
, pp. 35-39
-
-
Schiller, W.R.1
Garren, R.L.2
Bay, R.C.3
Ruddell, M.H.4
Holloway, G.A.5
Mohty, A.6
Luekens, C.A.7
-
7
-
-
0032944058
-
Blood flow compared in benign melanocyte naevi. malignant melanomas and basal cell carcinomas
-
M. Stucker, I. Horstmann, C. Nuchel, A. Rochling, K. Hoffmann, and P. Altmeyer, "Blood flow compared in benign melanocyte naevi. malignant melanomas and basal cell carcinomas," Clin. Exp. Dermatol. 24, 107-111 (1999).
-
(1999)
Clin. Exp. Dermatol
, vol.24
, pp. 107-111
-
-
Stucker, M.1
Horstmann, I.2
Nuchel, C.3
Rochling, A.4
Hoffmann, K.5
Altmeyer, P.6
-
8
-
-
0031919750
-
Doppler flowmetry in the planning of perforator flaps
-
P. N. Blondeel, G. Beyens, R. Verhaeghe, K. Van Landuyt, P. Tonnard, S. J. Monstrey, and G. Matton, "Doppler flowmetry in the planning of perforator flaps," Br. J. Plast. Surg. 51, 202-209 (1998).
-
(1998)
Br. J. Plast. Surg
, vol.51
, pp. 202-209
-
-
Blondeel, P.N.1
Beyens, G.2
Verhaeghe, R.3
Van Landuyt, K.4
Tonnard, P.5
Monstrey, S.J.6
Matton, G.7
-
9
-
-
0027295178
-
The study of plaques of psoriasis using a scanning laser-Doppler velocimeter
-
E. L. Speight, T. J. H. Essex, and P. M. Farr, "The study of plaques of psoriasis using a scanning laser-Doppler velocimeter," Br. J. Dermatol. 128, 519-524 (1993).
-
(1993)
Br. J. Dermatol
, vol.128
, pp. 519-524
-
-
Speight, E.L.1
Essex, T.J.H.2
Farr, P.M.3
-
10
-
-
0020909943
-
Spatial and temporal variations in human skin blood flow
-
T. Tenland, E. G. Salerud, G. E. Nilsson, and P. A. Oberg, "Spatial and temporal variations in human skin blood flow," Int. J. Microcirc.: Clin. Exp. 2, 81-89 (1983).
-
(1983)
Int. J. Microcirc.: Clin. Exp
, vol.2
, pp. 81-89
-
-
Tenland, T.1
Salerud, E.G.2
Nilsson, G.E.3
Oberg, P.A.4
-
11
-
-
0024782804
-
A survey of the laser Doppler technique for measurement of tissue perfusion
-
G. E. Nilsson, "A survey of the laser Doppler technique for measurement of tissue perfusion," Laser Therapy 1, 175-182 (1989).
-
(1989)
Laser Therapy
, vol.1
, pp. 175-182
-
-
Nilsson, G.E.1
-
12
-
-
0005016738
-
Imaging of tissue blood flow by coherent light scattering
-
G. E. Nilsson, A. Jakobsson, and L. Wardell, "Imaging of tissue blood flow by coherent light scattering," in Proc., 11th Ann. Int. Conf. IEEE Engineering in Medicine Soc., Vol. 2. pp. 391-392 (1989).
-
(1989)
Proc., 11th Ann. Int. Conf. IEEE Engineering in Medicine Soc
, vol.2
, pp. 391-392
-
-
Nilsson, G.E.1
Jakobsson, A.2
Wardell, L.3
-
13
-
-
0026156875
-
A laser Doppler scanner for imaging blood flow in skin
-
T. J. H. Essex and P. O. Byrne, "A laser Doppler scanner for imaging blood flow in skin," J. Biomed. Eng. 13, 189-194 (1991).
-
(1991)
J. Biomed. Eng
, vol.13
, pp. 189-194
-
-
Essex, T.J.H.1
Byrne, P.O.2
-
14
-
-
0035181228
-
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
-
J. D. Briers, "Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging," Physiol. Meas 22, R35-R66 (2001).
-
(2001)
Physiol. Meas
, vol.22
-
-
Briers, J.D.1
-
15
-
-
0036507635
-
Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor
-
A. Serov, W. Steenbergen, and F. De Mul, "Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor," Opt. Lett. 27(5), 300-302 (2002).
-
(2002)
Opt. Lett
, vol.27
, Issue.5
, pp. 300-302
-
-
Serov, A.1
Steenbergen, W.2
De Mul, F.3
-
16
-
-
24144454179
-
High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor
-
A. Serov and T. Lasser, "High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor," Opt. Express 13(17). 6416-6428 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.17
, pp. 6416-6428
-
-
Serov, A.1
Lasser, T.2
-
17
-
-
21244498202
-
Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera
-
A. Serov, B. Steinacher, and T. Lasser. "Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera," Opt. Express 13(10), 3681-3689 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.10
, pp. 3681-3689
-
-
Serov, A.1
Steinacher, B.2
Lasser, T.3
-
18
-
-
33646200709
-
Full-field high-speed laser Doppler imaging system for blood-flow measurements
-
A. Serov and T. Lasser, "Full-field high-speed laser Doppler imaging system for blood-flow measurements," Proc. SPIE 6080, 608004 (2006).
-
(2006)
Proc. SPIE
, vol.6080
, pp. 608004
-
-
Serov, A.1
Lasser, T.2
-
19
-
-
0036417698
-
Full-field laser vibrometry employing a novel CMOS-DSP camera
-
M. V. Aguanno, M. J. Connelly, and M. P. Whelan, "Full-field laser vibrometry employing a novel CMOS-DSP camera," Proc. SPIE 4827, 123-132 (2002).
-
(2002)
Proc. SPIE
, vol.4827
, pp. 123-132
-
-
Aguanno, M.V.1
Connelly, M.J.2
Whelan, M.P.3
-
20
-
-
1942510635
-
Single-pixel carrier-based approach for full-field laser interferometry using a CMOS-DSP camera
-
M. V. Aguanno, F. Lakestani, M. P. Whelan, and M. J. Connelly, "Single-pixel carrier-based approach for full-field laser interferometry using a CMOS-DSP camera," Proc. SPIE 5251, 304-312 (2004).
-
(2004)
Proc. SPIE
, vol.5251
, pp. 304-312
-
-
Aguanno, M.V.1
Lakestani, F.2
Whelan, M.P.3
Connelly, M.J.4
-
21
-
-
10044225578
-
Integration of a photodiode array and centroid processing on a single CMOS chip for a real-time Shack-Hartmann wavefront sensor
-
B. H. Pui, B. R. Hayes-Gill, M. Clark, M. G. Somekh, C. W. See, S. Morgan, and A. Ng, "Integration of a photodiode array and centroid processing on a single CMOS chip for a real-time Shack-Hartmann wavefront sensor," IEEE Sens. J. 4(8), 787-794 (2004).
-
(2004)
IEEE Sens. J
, vol.4
, Issue.8
, pp. 787-794
-
-
Pui, B.H.1
Hayes-Gill, B.R.2
Clark, M.3
Somekh, M.G.4
See, C.W.5
Morgan, S.6
Ng, A.7
-
22
-
-
0036641373
-
The design and characterisation of an optical VLSI processor for real time centroid detection
-
B. H. Pui, B. R. Hayes-Gill, M. Clark, M. G. Somekh, C. W. See, S. P. Morgan, and A. Ng, "The design and characterisation of an optical VLSI processor for real time centroid detection," Analog lntegr. Circuits Signal Process. 32, 67-75 (2002).
-
(2002)
Analog lntegr. Circuits Signal Process
, vol.32
, pp. 67-75
-
-
Pui, B.H.1
Hayes-Gill, B.R.2
Clark, M.3
Somekh, M.G.4
See, C.W.5
Morgan, S.P.6
Ng, A.7
-
23
-
-
12144256745
-
Laser Doppler blood flowmetry with FPGA processing
-
C. Kongsavatsak, D. He, S. P. Morgan, B. R. Hayes-Gill, J. A. Crowe, and M. Clark, "Laser Doppler blood flowmetry with FPGA processing," Proc. SPIE 5486, 141-147 (2003).
-
(2003)
Proc. SPIE
, vol.5486
, pp. 141-147
-
-
Kongsavatsak, C.1
He, D.2
Morgan, S.P.3
Hayes-Gill, B.R.4
Crowe, J.A.5
Clark, M.6
-
24
-
-
9144234920
-
Camera pixel for coherent detection of modulated light
-
P. Dmochowski, B. R. Hayes-Gill, M. Clark, J. A. Crowe, M. G. Somekh, and S. P. Morgan, "Camera pixel for coherent detection of modulated light," Electron. Lett. 40(22), 1403-1404 (2004).
-
(2004)
Electron. Lett
, vol.40
, Issue.22
, pp. 1403-1404
-
-
Dmochowski, P.1
Hayes-Gill, B.R.2
Clark, M.3
Crowe, J.A.4
Somekh, M.G.5
Morgan, S.P.6
-
25
-
-
0031595023
-
Effects of H1 antagonists on the cutaneous vascular response to histamine and bradykinin: A study using scanning laser Doppler imaging
-
G. F. Clough, A. R. Bennett, and M. K. Church, "Effects of H1 antagonists on the cutaneous vascular response to histamine and bradykinin: a study using scanning laser Doppler imaging," Br. J. Dermatol. 138, 806-814 (1998).
-
(1998)
Br. J. Dermatol
, vol.138
, pp. 806-814
-
-
Clough, G.F.1
Bennett, A.R.2
Church, M.K.3
-
26
-
-
0031834459
-
Transcutaneous delivery of prostaglandin El : In vitro and laser Doppler flowmetry study
-
M. Foldvari, C. Oguejiofor, T. Wilson, S. Afridi, and T. Kudel, "Transcutaneous delivery of prostaglandin El : in vitro and laser Doppler flowmetry study," J. Pharm. Sci. 87, 721-725 (1998).
-
(1998)
J. Pharm. Sci
, vol.87
, pp. 721-725
-
-
Foldvari, M.1
Oguejiofor, C.2
Wilson, T.3
Afridi, S.4
Kudel, T.5
-
27
-
-
49949096173
-
Laser, Doppler, blood, flow, CMOS, imaging, sensor, with, analog, on-chip, processing
-
Q. Gu, B. R. Hayes-Gill, and S. P. Morgan, "Laser, Doppler, blood, flow, CMOS, imaging, sensor, with, analog, on-chip, processing," Appl. Opt. 47(12), 2061-2069, (2008).
-
(2008)
Appl. Opt
, vol.47
, Issue.12
, pp. 2061-2069
-
-
Gu, Q.1
Hayes-Gill, B.R.2
Morgan, S.P.3
-
29
-
-
0022031047
-
Active filter design using operational transconductance amplifiers: A tutorial
-
R. L. Geiger and E. Sanchez-Sinencio, "Active filter design using operational transconductance amplifiers: a tutorial," IEEE Circuits Devices Mag. 1, 20-32 (1985).
-
(1985)
IEEE Circuits Devices Mag
, vol.1
, pp. 20-32
-
-
Geiger, R.L.1
Sanchez-Sinencio, E.2
-
30
-
-
0037817786
-
A 0.5-V 1-μW successive approximation ADC
-
J. Sauerbrey, D. Schmitt-Landsiedel, and R. Thewes, "A 0.5-V 1-μW successive approximation ADC," IEEE J. Solid-State Circuits 38, 1261-1265 (2003).
-
(2003)
IEEE J. Solid-State Circuits
, vol.38
, pp. 1261-1265
-
-
Sauerbrey, J.1
Schmitt-Landsiedel, D.2
Thewes, R.3
-
32
-
-
0004259911
-
-
Kluwer Academic Publishers
-
A. Moini, Vision Chips, Kluwer Academic Publishers (2000).
-
(2000)
Vision Chips
-
-
Moini, A.1
-
33
-
-
33646201719
-
CMOS detection methods in ultrasound modulated optical tomography
-
S. P. Morgan, C. Li, B. R. Hayes-Gill, N. B. E. Sawyer, and C. Kongsavatsak, "CMOS detection methods in ultrasound modulated optical tomography," Proc. SPIE 6086, 8615-8615 (2006).
-
(2006)
Proc. SPIE
, vol.6086
, pp. 8615-8615
-
-
Morgan, S.P.1
Li, C.2
Hayes-Gill, B.R.3
Sawyer, N.B.E.4
Kongsavatsak, C.5
-
34
-
-
54149108626
-
-
Maxim Integrated Products, Defining and testing dynamic parameters in high-speed ADCs, Application notes 728, Maxim Integrated Products, Beaverton, OR (2001).
-
Maxim Integrated Products, "Defining and testing dynamic parameters in high-speed ADCs," Application notes 728, Maxim Integrated Products, Beaverton, OR (2001).
-
-
-
-
35
-
-
0036825995
-
Modeling, calibration and correction of nonlinear illumination-dependent fixed pattern noise in logarithmic CMOS image sensors
-
D. Joseph and S. Collins, "Modeling, calibration and correction of nonlinear illumination-dependent fixed pattern noise in logarithmic CMOS image sensors," IEEE Trans. Instrum. Meas. 51(5), 996-1001 (2002).
-
(2002)
IEEE Trans. Instrum. Meas
, vol.51
, Issue.5
, pp. 996-1001
-
-
Joseph, D.1
Collins, S.2
|