메뉴 건너뛰기




Volumn 55, Issue 10, 2008, Pages 2191-2197

Ultrasonic assessment of cortical bone thickness in vitro and in vivo

Author keywords

[No Author keywords available]

Indexed keywords

DISEASES; SYSTEMATIC ERRORS;

EID: 54049141753     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.918     Document Type: Article
Times cited : (48)

References (26)
  • 1
    • 0021222303 scopus 로고
    • Age-related structural changes in trabecular and cortical bone: Cellular mechanisms and biomechanical consequences
    • A. M. Parfitt, "Age-related structural changes in trabecular and cortical bone: Cellular mechanisms and biomechanical consequences," Calcif. Tissue Int., vol. 36, Suppl 1, pp. S123-S128, 1984.
    • (1984) Calcif. Tissue Int , vol.36 , Issue.SUPPL. 1
    • Parfitt, A.M.1
  • 2
    • 0031973823 scopus 로고    scopus 로고
    • Changes in the stiffness, strength, and toughness of human cortical bone with age
    • P. Zioupos and J. D. Currey, "Changes in the stiffness, strength, and toughness of human cortical bone with age," Bone, vol. 22, pp. 57-66, 1998.
    • (1998) Bone , vol.22 , pp. 57-66
    • Zioupos, P.1    Currey, J.D.2
  • 3
    • 0029841074 scopus 로고    scopus 로고
    • Prediction of fracture load at different skeletal sites by geometric properties of the cortical shell
    • P. Augat, H. Reeb, and L. E. Claes, "Prediction of fracture load at different skeletal sites by geometric properties of the cortical shell," J. Bone Miner. Res., vol. 11, pp. 1356-1363, 1996.
    • (1996) J. Bone Miner. Res , vol.11 , pp. 1356-1363
    • Augat, P.1    Reeb, H.2    Claes, L.E.3
  • 4
    • 33645334942 scopus 로고    scopus 로고
    • Cortical pQCT measures are associated with fractures in dialysis patients
    • S. A. Jamal, J. Gilbert, C. Gordon, and D. C. Bauer, "Cortical pQCT measures are associated with fractures in dialysis patients," J. Bone Miner. Res., vol. 21, pp. 543-548, 2006.
    • (2006) J. Bone Miner. Res , vol.21 , pp. 543-548
    • Jamal, S.A.1    Gilbert, J.2    Gordon, C.3    Bauer, D.C.4
  • 5
    • 0038382305 scopus 로고    scopus 로고
    • Autocorrelation and cepstral methods for measurement of tibial cortical thickness
    • K. A. Wear, "Autocorrelation and cepstral methods for measurement of tibial cortical thickness," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 50, pp. 655-660, 2003.
    • (2003) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.50 , pp. 655-660
    • Wear, K.A.1
  • 6
    • 0014055288 scopus 로고
    • Cepstrum pitch determination
    • A. M. Noll, "Cepstrum pitch determination," J. Acoust Soc. Am., vol. 41, pp. 293-309, 1967.
    • (1967) J. Acoust Soc. Am , vol.41 , pp. 293-309
    • Noll, A.M.1
  • 7
    • 0017542202 scopus 로고
    • The cepstrum: A guide to processing
    • D. G. Childers, D. P. Skinner, and R. C. Kemerait, "The cepstrum: A guide to processing," Proc. IEEE, vol. 65, pp. 1428-1443, 1977.
    • (1977) Proc. IEEE , vol.65 , pp. 1428-1443
    • Childers, D.G.1    Skinner, D.P.2    Kemerait, R.C.3
  • 8
    • 0031021721 scopus 로고    scopus 로고
    • Ultrasonic wave propagation in bovine cancellous bone
    • A. Hosokawa and T. Otani, "Ultrasonic wave propagation in bovine cancellous bone," J. Acoust. Soc. Am., vol. 101, pp. 558-562, 1997.
    • (1997) J. Acoust. Soc. Am , vol.101 , pp. 558-562
    • Hosokawa, A.1    Otani, T.2
  • 9
    • 0019868774 scopus 로고
    • Measurement of the velocity of ultrasound in human cortical bone in vivo. Estimation of its potential value in the diagnosis of osteoporosis and metabolic bone disease
    • M. A. Greenfield, J. D. Craven, A. Huddleston, M. L. Kehrer, D. Wishko, and R. Stern, "Measurement of the velocity of ultrasound in human cortical bone in vivo. Estimation of its potential value in the diagnosis of osteoporosis and metabolic bone disease," Radiology, vol. 138, pp. 701-710, 1981.
    • (1981) Radiology , vol.138 , pp. 701-710
    • Greenfield, M.A.1    Craven, J.D.2    Huddleston, A.3    Kehrer, M.L.4    Wishko, D.5    Stern, R.6
  • 10
    • 0024634642 scopus 로고
    • Ultrasonic non-destructive measurements of cortical bone thickness in human cadaver femur
    • S. Singh, "Ultrasonic non-destructive measurements of cortical bone thickness in human cadaver femur," Ultrasonics, vol. 27, pp. 107-113, 1989.
    • (1989) Ultrasonics , vol.27 , pp. 107-113
    • Singh, S.1
  • 11
    • 0032033723 scopus 로고    scopus 로고
    • Evaluation of acoustical parameter sensitivity to age-related and osteoarthritic changes in articular cartilage using 50-MHz ultrasound
    • E. Cherin, A. Saied, P. Laugier, P. Netter, and G. Berger, "Evaluation of acoustical parameter sensitivity to age-related and osteoarthritic changes in articular cartilage using 50-MHz ultrasound," Ultrasound Med. Biol., vol. 24, pp. 341-354, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , pp. 341-354
    • Cherin, E.1    Saied, A.2    Laugier, P.3    Netter, P.4    Berger, G.5
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • M. J. Bland and D. G. Altaian, "Statistical methods for assessing agreement between two methods of clinical measurement," Lancet, vol. 1, pp. 307-310, 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, M.J.1    Altaian, D.G.2
  • 14
    • 0015593173 scopus 로고
    • Measurement of the velocity of ultrasound in human cortical bone and its potential clinical importance. An in vivo preliminary study
    • J. D. Craven, M. A. Costantini, M. A. Greenfield, and R. Stern, "Measurement of the velocity of ultrasound in human cortical bone and its potential clinical importance. An in vivo preliminary study," Invest. Radiol., vol. 8, pp. 72-77, 1973.
    • (1973) Invest. Radiol , vol.8 , pp. 72-77
    • Craven, J.D.1    Costantini, M.A.2    Greenfield, M.A.3    Stern, R.4
  • 15
    • 0018884608 scopus 로고
    • Measurement of the velocity of ultrasound in the human femur in vivo
    • M. P. Andre, J. D. Craven, M. A. Greenfield, and R. Stern, "Measurement of the velocity of ultrasound in the human femur in vivo," Med. Phys., vol. 7, pp. 324-330, 1980.
    • (1980) Med. Phys , vol.7 , pp. 324-330
    • Andre, M.P.1    Craven, J.D.2    Greenfield, M.A.3    Stern, R.4
  • 17
    • 0034963825 scopus 로고    scopus 로고
    • Ultrasound velocity and cortical bone characteristics in vivo
    • H. Sievänen, S. Cheng, S. Ollikainen, and K. Uusi-Rasi, "Ultrasound velocity and cortical bone characteristics in vivo," Osteoporos. Int., vol. 12, pp. 399-405, 2001.
    • (2001) Osteoporos. Int , vol.12 , pp. 399-405
    • Sievänen, H.1    Cheng, S.2    Ollikainen, S.3    Uusi-Rasi, K.4
  • 20
    • 0017939514 scopus 로고
    • Ultrasonic velocity and attenuation in mammalian tissues
    • R. C. Chivers and R. J. Parry, "Ultrasonic velocity and attenuation in mammalian tissues," J. Acoust. Soc. Am., vol. 63, pp. 940-953, 1978.
    • (1978) J. Acoust. Soc. Am , vol.63 , pp. 940-953
    • Chivers, R.C.1    Parry, R.J.2
  • 21
    • 33845202518 scopus 로고    scopus 로고
    • Bone fragility: Failure of periosteal apposition to compensate for increased endocortical resorption in postmenopausal women
    • P. Szulc, E. Seeman, F. Duboeuf, E. Soruay-Rendu, and P. D. Delmas, "Bone fragility: Failure of periosteal apposition to compensate for increased endocortical resorption in postmenopausal women," J. Bone Miner. Res., vol. 21, pp. 1856-1863, 2006.
    • (2006) J. Bone Miner. Res , vol.21 , pp. 1856-1863
    • Szulc, P.1    Seeman, E.2    Duboeuf, F.3    Soruay-Rendu, E.4    Delmas, P.D.5
  • 23
    • 33745728836 scopus 로고    scopus 로고
    • Accuracy of pQCT for evaluating the aged human radius: An ashing, histomorphonietry and failure load investigation
    • M. C. Ashe, K. M. Khan, S. A. Kontulainen, P. Guy, D. Liu, T. J. Beck, and H. A. McKay, "Accuracy of pQCT for evaluating the aged human radius: An ashing, histomorphonietry and failure load investigation," Osteoporos. Int., vol. 17, pp. 1241-1251, 2006.
    • (2006) Osteoporos. Int , vol.17 , pp. 1241-1251
    • Ashe, M.C.1    Khan, K.M.2    Kontulainen, S.A.3    Guy, P.4    Liu, D.5    Beck, T.J.6    McKay, H.A.7
  • 24
    • 0031715104 scopus 로고    scopus 로고
    • Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT)
    • P. Augat, C. L. Gordon, T. F. Lang, H. Iida, and H. K. Genant, "Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT)," Phys. Med. Biol., vol. 43, pp. 2873-2883, 1998.
    • (1998) Phys. Med. Biol , vol.43 , pp. 2873-2883
    • Augat, P.1    Gordon, C.L.2    Lang, T.F.3    Iida, H.4    Genant, H.K.5
  • 25
    • 0242493664 scopus 로고    scopus 로고
    • Accuracy of peripheral quantitative computed tomography (pQCT) for assessing area and density of mouse cortical bone
    • M. D. Brodt, G. B. Pelz, J. Taniguchi, and M. J. Silva, "Accuracy of peripheral quantitative computed tomography (pQCT) for assessing area and density of mouse cortical bone," Calcif. Tissue Int., vol. 73, pp. 411-418, 2003.
    • (2003) Calcif. Tissue Int , vol.73 , pp. 411-418
    • Brodt, M.D.1    Pelz, G.B.2    Taniguchi, J.3    Silva, M.J.4
  • 26
    • 33846673917 scopus 로고    scopus 로고
    • Analyzing cortical bone cross-sectional geometry by peripheral QCT: Comparison with bone histomorphometry
    • S. Kontulainen, D. Liu, S. Manske, M. Jamieson, H. Sievanen, and H. McKay, "Analyzing cortical bone cross-sectional geometry by peripheral QCT: Comparison with bone histomorphometry," J. Clin. Densitom., vol. 10, pp. 86-92, 2007.
    • (2007) J. Clin. Densitom , vol.10 , pp. 86-92
    • Kontulainen, S.1    Liu, D.2    Manske, S.3    Jamieson, M.4    Sievanen, H.5    McKay, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.