메뉴 건너뛰기




Volumn 136, Issue 4, 2008, Pages 962-967

Regional differences in tissue oxygenation during cardiopulmonary bypass for correction of congenital heart disease in neonates and small infants: Relevance of near-infrared spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD SAMPLING; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CONGENITAL HEART DISEASE; CONTROLLED STUDY; FEMALE; HUMAN; INFANT; LACTATE BLOOD LEVEL; MALE; NEAR INFRARED SPECTROSCOPY; NEWBORN; OXYGEN SATURATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TISSUE OXYGENATION;

EID: 54049116734     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2007.12.058     Document Type: Article
Times cited : (43)

References (27)
  • 1
    • 33745200044 scopus 로고    scopus 로고
    • Current assessment of mortality rates in congenital cardiac surgery
    • Welke K.F., Shen I., and Ungerleider R.M. Current assessment of mortality rates in congenital cardiac surgery. Ann Thorac Surg 82 (2006) 164-170
    • (2006) Ann Thorac Surg , vol.82 , pp. 164-170
    • Welke, K.F.1    Shen, I.2    Ungerleider, R.M.3
  • 3
    • 30744460143 scopus 로고    scopus 로고
    • Long-term neuromotor outcome at school entry of infants with congenital heart defects requiring open-heart surgery
    • Majnemer A., Limperopoulos C., Shevell M., Rosenblatt B., Rohlicek C., and Tchervenkov C. Long-term neuromotor outcome at school entry of infants with congenital heart defects requiring open-heart surgery. J Pediatr 148 (2006) 72-77
    • (2006) J Pediatr , vol.148 , pp. 72-77
    • Majnemer, A.1    Limperopoulos, C.2    Shevell, M.3    Rosenblatt, B.4    Rohlicek, C.5    Tchervenkov, C.6
  • 5
    • 34248339077 scopus 로고    scopus 로고
    • Neurodevelopmental outcomes following congenital heart surgery
    • Ballweg J.A., Wernovsky G., and Gaynor J.W. Neurodevelopmental outcomes following congenital heart surgery. Pediatr Cardiol 28 (2007) 126-133
    • (2007) Pediatr Cardiol , vol.28 , pp. 126-133
    • Ballweg, J.A.1    Wernovsky, G.2    Gaynor, J.W.3
  • 6
    • 33747634678 scopus 로고    scopus 로고
    • Health and well-being of children with congenital cardiac malformations, and their families, following open-heart surgery
    • Majnemer A., Limperopoulos C., Shevell M., Rohlicek C., Rosenblatt B., and Tchervenkov C. Health and well-being of children with congenital cardiac malformations, and their families, following open-heart surgery. Cardiol Young 16 (2006) 57-164
    • (2006) Cardiol Young , vol.16 , pp. 57-164
    • Majnemer, A.1    Limperopoulos, C.2    Shevell, M.3    Rohlicek, C.4    Rosenblatt, B.5    Tchervenkov, C.6
  • 7
    • 33846660111 scopus 로고    scopus 로고
    • Temporal and anatomic risk profile of brain injury with neonatal repair of congenital heart defects
    • McQuillen P.S., Barkovich A.J., Hamrick S.E., Perez M., Ward P., Glidden D.V., et al. Temporal and anatomic risk profile of brain injury with neonatal repair of congenital heart defects. Stroke 38 (2007) 736-741
    • (2007) Stroke , vol.38 , pp. 736-741
    • McQuillen, P.S.1    Barkovich, A.J.2    Hamrick, S.E.3    Perez, M.4    Ward, P.5    Glidden, D.V.6
  • 8
    • 0025337790 scopus 로고
    • Quality control of perfusion: monitoring venous blood oxygen tension to prevent hypoxic acidosis
    • Swan H., Sanchez M., Tyndall M., and Koch C. Quality control of perfusion: monitoring venous blood oxygen tension to prevent hypoxic acidosis. J Thorac Cardiovasc Surg 99 (1990) 868-872
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 868-872
    • Swan, H.1    Sanchez, M.2    Tyndall, M.3    Koch, C.4
  • 9
    • 0036207745 scopus 로고    scopus 로고
    • The relationship between mixed venous and regional venous oxygen saturation during cardiopulmonary bypass
    • Lindholm L., Hansdottir V., Lundqvist M., and Jeppsson A. The relationship between mixed venous and regional venous oxygen saturation during cardiopulmonary bypass. Perfusion 17 (2002) 133-139
    • (2002) Perfusion , vol.17 , pp. 133-139
    • Lindholm, L.1    Hansdottir, V.2    Lundqvist, M.3    Jeppsson, A.4
  • 10
    • 0028911113 scopus 로고
    • Mixed venous oxygen saturation during cardiopulmonary bypass poorly predicts regional venous saturation
    • McDaniel L.B., Zwischenberger J.B., Vertrees R.A., Nutt L., Uchida T., Nguyen T., et al. Mixed venous oxygen saturation during cardiopulmonary bypass poorly predicts regional venous saturation. Anesth Analg 80 (1995) 466-472
    • (1995) Anesth Analg , vol.80 , pp. 466-472
    • McDaniel, L.B.1    Zwischenberger, J.B.2    Vertrees, R.A.3    Nutt, L.4    Uchida, T.5    Nguyen, T.6
  • 12
    • 34147093080 scopus 로고    scopus 로고
    • Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: concordance and association with clinical variables
    • McQuillen P.S., Nishimoto M.S., Bottrell C.L., Fineman L.D., Hamrick S.E., Glidden D.V., et al. Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: concordance and association with clinical variables. Pediatr Crit Care Med 8 (2007) 154-160
    • (2007) Pediatr Crit Care Med , vol.8 , pp. 154-160
    • McQuillen, P.S.1    Nishimoto, M.S.2    Bottrell, C.L.3    Fineman, L.D.4    Hamrick, S.E.5    Glidden, D.V.6
  • 14
    • 33745455634 scopus 로고    scopus 로고
    • Detection of lower torso ischemia by near-infrared spectroscopy during cardiopulmonary bypass in a 6.8-kg infant with complex aortic anatomy
    • Redlin M., Boettcher W., Huebler M., Berger F., Hetzer R., Koster A., et al. Detection of lower torso ischemia by near-infrared spectroscopy during cardiopulmonary bypass in a 6.8-kg infant with complex aortic anatomy. Ann Thorac Surg 82 (2006) 323-325
    • (2006) Ann Thorac Surg , vol.82 , pp. 323-325
    • Redlin, M.1    Boettcher, W.2    Huebler, M.3    Berger, F.4    Hetzer, R.5    Koster, A.6
  • 15
    • 0027067074 scopus 로고
    • Experimentally measured optical pathlengths for the adult head, calf and forearm and the head of the newborn infant as a function of inter optode spacing
    • van der Zee P., Cope M., Arridge S.R., Essenpreis M., Potter L.A., Edwards A.D., et al. Experimentally measured optical pathlengths for the adult head, calf and forearm and the head of the newborn infant as a function of inter optode spacing. Adv Exp Med Biol 316 (1992) 143-153
    • (1992) Adv Exp Med Biol , vol.316 , pp. 143-153
    • van der Zee, P.1    Cope, M.2    Arridge, S.R.3    Essenpreis, M.4    Potter, L.A.5    Edwards, A.D.6
  • 16
    • 85018149579 scopus 로고
    • Absolute quantification methods in tissue near infrared spectroscopy
    • Matcher S.J., Kirkpatrick P.J., Nahid K., Cope M., and Delpy D.T. Absolute quantification methods in tissue near infrared spectroscopy. Proc SPIE 2389 (1995) 486-495
    • (1995) Proc SPIE , vol.2389 , pp. 486-495
    • Matcher, S.J.1    Kirkpatrick, P.J.2    Nahid, K.3    Cope, M.4    Delpy, D.T.5
  • 17
    • 0033339492 scopus 로고    scopus 로고
    • A tissue oxygenation monitor using NIR spatially resolved spectroscopy
    • Suzuki S., Takasaki S., Ozaki T., and Kobayashi Y. A tissue oxygenation monitor using NIR spatially resolved spectroscopy. Proc SPIE 3597 (1999) 582-592
    • (1999) Proc SPIE , vol.3597 , pp. 582-592
    • Suzuki, S.1    Takasaki, S.2    Ozaki, T.3    Kobayashi, Y.4
  • 18
    • 34247155695 scopus 로고    scopus 로고
    • Transfusion-free cardiac reoperation in an 11-kg Jehovah's Witness child by use of a minimized cardiopulmonary bypass circuit
    • Huebler M., Boettcher W., Koster A., Stiller B., Kuppe H., and Hetzer R. Transfusion-free cardiac reoperation in an 11-kg Jehovah's Witness child by use of a minimized cardiopulmonary bypass circuit. Tex Heart Inst J 34 (2007) 108-111
    • (2007) Tex Heart Inst J , vol.34 , pp. 108-111
    • Huebler, M.1    Boettcher, W.2    Koster, A.3    Stiller, B.4    Kuppe, H.5    Hetzer, R.6
  • 19
    • 0035412833 scopus 로고    scopus 로고
    • Mixed venous oxygen saturation does not adequately predict cerebral perfusion during pediatric cardiopulmonary bypass
    • Yeh Jr. T., Gouldman J., Auden S.M., Seremet V., Edmonds Jr. H.L., Cerrito P.B., et al. Mixed venous oxygen saturation does not adequately predict cerebral perfusion during pediatric cardiopulmonary bypass. J Thorac Cardiovasc Surg 122 (2001) 192-193
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 192-193
    • Yeh Jr., T.1    Gouldman, J.2    Auden, S.M.3    Seremet, V.4    Edmonds Jr., H.L.5    Cerrito, P.B.6
  • 20
    • 20444449773 scopus 로고    scopus 로고
    • A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
    • Tortoriello T.A., Stayer S.A., Mott A.R., McKenzie E.D., Fraser C.D., Andropoulos D.B., et al. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Paediatr Anaesth 15 (2005) 495-503
    • (2005) Paediatr Anaesth , vol.15 , pp. 495-503
    • Tortoriello, T.A.1    Stayer, S.A.2    Mott, A.R.3    McKenzie, E.D.4    Fraser, C.D.5    Andropoulos, D.B.6
  • 21
    • 13944272666 scopus 로고    scopus 로고
    • Near-infrared spectroscopic cerebral oxygenation reading in neonates and infants is associated with central venous oxygen saturation
    • Weiss M., Dullenkopf A., Kolarova A., Schulz G., Frey B., and Baenziger O. Near-infrared spectroscopic cerebral oxygenation reading in neonates and infants is associated with central venous oxygen saturation. Paediatr Anaesth 15 (2005) 102-109
    • (2005) Paediatr Anaesth , vol.15 , pp. 102-109
    • Weiss, M.1    Dullenkopf, A.2    Kolarova, A.3    Schulz, G.4    Frey, B.5    Baenziger, O.6
  • 22
    • 0029124960 scopus 로고
    • Jugular bulb saturation and mixed venous saturation during cardiopulmonary bypass
    • Croughwell N.D., White W.D., Smith L.R., Davis R.D., Glower Jr. D.D., Reves J.G., et al. Jugular bulb saturation and mixed venous saturation during cardiopulmonary bypass. J Card Surg 10 4 Suppl (1995) 503-508
    • (1995) J Card Surg , vol.10 , Issue.4 SUPPL , pp. 503-508
    • Croughwell, N.D.1    White, W.D.2    Smith, L.R.3    Davis, R.D.4    Glower Jr., D.D.5    Reves, J.G.6
  • 23
    • 0029927968 scopus 로고    scopus 로고
    • Cerebral oxygenation measured by near-infrared spectroscopy: comparison with jugular bulb oximetry
    • Daubeney P.E., Pilkington S.N., Janke E., Charlton G.A., Smith D.C., and Webber S.A. Cerebral oxygenation measured by near-infrared spectroscopy: comparison with jugular bulb oximetry. Ann Thorac Surg 61 (1996) 930-934
    • (1996) Ann Thorac Surg , vol.61 , pp. 930-934
    • Daubeney, P.E.1    Pilkington, S.N.2    Janke, E.3    Charlton, G.A.4    Smith, D.C.5    Webber, S.A.6
  • 24
    • 21244490736 scopus 로고    scopus 로고
    • Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children
    • Nagdyman N., Fleck T., Schubert S., Ewert P., Peters B., Lange P.E., et al. Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med 31 (2005) 846-850
    • (2005) Intensive Care Med , vol.31 , pp. 846-850
    • Nagdyman, N.1    Fleck, T.2    Schubert, S.3    Ewert, P.4    Peters, B.5    Lange, P.E.6
  • 25
    • 0035172972 scopus 로고    scopus 로고
    • Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head
    • Al-Rawi P.G., Smielewski P., and Kirkpatrick P.J. Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head. Stroke 32 (2001) 2492-2500
    • (2001) Stroke , vol.32 , pp. 2492-2500
    • Al-Rawi, P.G.1    Smielewski, P.2    Kirkpatrick, P.J.3
  • 27
    • 22044456172 scopus 로고    scopus 로고
    • The significance of baseline cerebral oxygen saturation in children undergoing congenital heart surgery
    • Fenton K.N., Freeman K., Glogowski K., Fogg S., and Duncan K.F. The significance of baseline cerebral oxygen saturation in children undergoing congenital heart surgery. Am J Surg 190 (2005) 260-263
    • (2005) Am J Surg , vol.190 , pp. 260-263
    • Fenton, K.N.1    Freeman, K.2    Glogowski, K.3    Fogg, S.4    Duncan, K.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.