-
1
-
-
0027372664
-
In vivo performance evaluation of a transcutaneous energy and information transmission system for the total artificial heart
-
Ahn J.M., Kang D.W., Kim H.C., and Min B.G. In vivo performance evaluation of a transcutaneous energy and information transmission system for the total artificial heart. ASAIO J. (1992) 39 (1993) M208-M212
-
(1993)
ASAIO J. (1992)
, vol.39
-
-
Ahn, J.M.1
Kang, D.W.2
Kim, H.C.3
Min, B.G.4
-
2
-
-
0034959307
-
Evaluation of the Intelisite capsule to deliver theophylline and frusemide tablets to the small intestine and colon
-
Clear N.J., Milton A., Humphrey M., Henry B.T., Wulff M., Nichols D.J., Anziano R.J., and Wilding I. Evaluation of the Intelisite capsule to deliver theophylline and frusemide tablets to the small intestine and colon. Eur. J. Pharm. Sci.: Official J. Eur. Fed. Pharm. Sci. 13 (2001) 375-384
-
(2001)
Eur. J. Pharm. Sci.: Official J. Eur. Fed. Pharm. Sci.
, vol.13
, pp. 375-384
-
-
Clear, N.J.1
Milton, A.2
Humphrey, M.3
Henry, B.T.4
Wulff, M.5
Nichols, D.J.6
Anziano, R.J.7
Wilding, I.8
-
3
-
-
0018242895
-
An inductively powered telemetry system for temperature, EKG, and activity monitoring
-
Fryer T.B., Lund G.F., and Williams B.A. An inductively powered telemetry system for temperature, EKG, and activity monitoring. Biotelemetry Patient Monit. 5 (1978) 53-76
-
(1978)
Biotelemetry Patient Monit.
, vol.5
, pp. 53-76
-
-
Fryer, T.B.1
Lund, G.F.2
Williams, B.A.3
-
5
-
-
0030250679
-
Development of a high permeability cored transintegumental power transformer
-
Helmicki A.J., Melvin D.M., Henderson H.T., Nebrigic D., Venkat R., and Glos D.L. Development of a high permeability cored transintegumental power transformer. ASAIO J. (1992) 42 (1996) M624-M629
-
(1996)
ASAIO J. (1992)
, vol.42
-
-
Helmicki, A.J.1
Melvin, D.M.2
Henderson, H.T.3
Nebrigic, D.4
Venkat, R.5
Glos, D.L.6
-
6
-
-
0009636722
-
Absorption of isosorbide 5-nitrate from the gastrointestinal tract
-
Laufen H., and Wildfeuer A. Absorption of isosorbide 5-nitrate from the gastrointestinal tract. Methods in Clinical Pharmacology 7 (1987) 76-81
-
(1987)
Methods in Clinical Pharmacology
, vol.7
, pp. 76-81
-
-
Laufen, H.1
Wildfeuer, A.2
-
8
-
-
0032217231
-
Use of the InteliSite capsule to study ranitidine absorption from various sites within the human intestinal tract
-
Pithavala Y.K., Heizer W.D., Parr A.F., O'connor-Semmes R.L., and Brouwer K.L.R. Use of the InteliSite capsule to study ranitidine absorption from various sites within the human intestinal tract. Pharm. Res. 15 (1998) 1869-1875
-
(1998)
Pharm. Res.
, vol.15
, pp. 1869-1875
-
-
Pithavala, Y.K.1
Heizer, W.D.2
Parr, A.F.3
O'connor-Semmes, R.L.4
Brouwer, K.L.R.5
-
9
-
-
0036720841
-
Neuroelectric mechanisms applied to low frequency electric and magnetic field exposure guidelines. Part I. sinusoidal waveforms
-
Reilly J.P. Neuroelectric mechanisms applied to low frequency electric and magnetic field exposure guidelines. Part I. sinusoidal waveforms. Health Phys. 83 (2002) 341-355
-
(2002)
Health Phys.
, vol.83
, pp. 341-355
-
-
Reilly, J.P.1
-
10
-
-
0009582182
-
Course of development of the HF-capsule - variations and method-related typical findings
-
Schuster O., and Hugemann B. Course of development of the HF-capsule - variations and method-related typical findings. Methods in Clinical Pharmacology 7 (1987) 28-38
-
(1987)
Methods in Clinical Pharmacology
, vol.7
, pp. 28-38
-
-
Schuster, O.1
Hugemann, B.2
-
11
-
-
0027454370
-
In vivo testing of a completely implanted total artificial heart system
-
Snyder A.J., Rosenberg G., Weiss W.J., Ford S.K., Nazarian R.A., Hicks D.L., Marlotte J.A., Kawaguchi O., Prophet G.A., and Sapirstein J.S. In vivo testing of a completely implanted total artificial heart system. ASAIO J. (1992) 39 (1993) M177-M184
-
(1993)
ASAIO J. (1992)
, vol.39
-
-
Snyder, A.J.1
Rosenberg, G.2
Weiss, W.J.3
Ford, S.K.4
Nazarian, R.A.5
Hicks, D.L.6
Marlotte, J.A.7
Kawaguchi, O.8
Prophet, G.A.9
Sapirstein, J.S.10
-
12
-
-
0026883619
-
Closed-loop class E transcutaneous power and data link for microimplants
-
Troyk P.R., and Schwan M.A. Closed-loop class E transcutaneous power and data link for microimplants. IEEE Transact. Bio-Med. Eng. 39 (1992) 589-599
-
(1992)
IEEE Transact. Bio-Med. Eng.
, vol.39
, pp. 589-599
-
-
Troyk, P.R.1
Schwan, M.A.2
-
13
-
-
0024705411
-
In vivo performance of a transcutaneous energy transmission system with the Penn State motor driven ventricular assist device
-
Weiss W.J., Rosenberg G., Snyder A.J., Pae W.E., Richenbacher W.E., and Pierce W.S. In vivo performance of a transcutaneous energy transmission system with the Penn State motor driven ventricular assist device. ASAIO J. Transact. 35 (1989) 284-288
-
(1989)
ASAIO J. Transact.
, vol.35
, pp. 284-288
-
-
Weiss, W.J.1
Rosenberg, G.2
Snyder, A.J.3
Pae, W.E.4
Richenbacher, W.E.5
Pierce, W.S.6
-
14
-
-
0026877885
-
Transcutaneous transmission of digital data and energy in a cochlear prosthesis system
-
Zierhofer M.C., and Hochmair E.S. Transcutaneous transmission of digital data and energy in a cochlear prosthesis system. Int. J. Artif. Org. 15 (1992) 379-382
-
(1992)
Int. J. Artif. Org.
, vol.15
, pp. 379-382
-
-
Zierhofer, M.C.1
Hochmair, E.S.2
|