메뉴 건너뛰기




Volumn 23, Issue 9, 2008, Pages 1141-1147

Mechanical aspects of degree of cement bonding and implant wedge effect

Author keywords

Debond; Polish; Stem; Taper; THA (total hip arthroplasty)

Indexed keywords

ALUMINA; BONE; CEMENT MANUFACTURE; CEMENTS; CYLINDERS (SHAPES); FAILURE ANALYSIS; FINITE ELEMENT METHOD; HIP PROSTHESES; QUALITY ASSURANCE; SHEAR STRENGTH; SHELLS (STRUCTURES); STAINLESS STEEL;

EID: 53649104320     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2008.05.003     Document Type: Article
Times cited : (7)

References (35)
  • 1
    • 0348148490 scopus 로고
    • Directly bone-anchored implants: with special emphasis on the concepts of osseointegration in orthopedic surgery
    • Albrektsson T., Carlsson A., Morberg P., and Wennerberg A. Directly bone-anchored implants: with special emphasis on the concepts of osseointegration in orthopedic surgery. Bone Implant Interface (1994) 97-120
    • (1994) Bone Implant Interface , pp. 97-120
    • Albrektsson, T.1    Carlsson, A.2    Morberg, P.3    Wennerberg, A.4
  • 2
    • 0032945290 scopus 로고    scopus 로고
    • Cement migration after THR. A comparison of Charnley Elite and Exeter femoral stems using RSA
    • Alfaro-Adrian J., Gill H.S., and Murray D.W. Cement migration after THR. A comparison of Charnley Elite and Exeter femoral stems using RSA. J. Bone Joint Surg. Br. 81 (1999) 130-134
    • (1999) J. Bone Joint Surg. Br. , vol.81 , pp. 130-134
    • Alfaro-Adrian, J.1    Gill, H.S.2    Murray, D.W.3
  • 3
    • 0034886433 scopus 로고    scopus 로고
    • Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems
    • Alfaro-Adrian J., Gill H.S., and Murray D.W. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems. J. Arthroplasty 16 (2001) 598-606
    • (2001) J. Arthroplasty , vol.16 , pp. 598-606
    • Alfaro-Adrian, J.1    Gill, H.S.2    Murray, D.W.3
  • 4
    • 0001280121 scopus 로고
    • The effect of intramedullary reaming on the strength of the cement/bone interface
    • Balu G.R., Noble P.C., Alexander J.W., and Vela V.L. The effect of intramedullary reaming on the strength of the cement/bone interface. Trans. Orthop. Res. Soc. 19 (1994) 797
    • (1994) Trans. Orthop. Res. Soc. , vol.19 , pp. 797
    • Balu, G.R.1    Noble, P.C.2    Alexander, J.W.3    Vela, V.L.4
  • 5
    • 0023606505 scopus 로고
    • Regional variation in shear strength of the bone-polymethylmethacrylate interface
    • Bean D.J., Convery F.R., Woo S.L., and Lieber R.L. Regional variation in shear strength of the bone-polymethylmethacrylate interface. J. Arthroplasty 2 (1987) 293-298
    • (1987) J. Arthroplasty , vol.2 , pp. 293-298
    • Bean, D.J.1    Convery, F.R.2    Woo, S.L.3    Lieber, R.L.4
  • 6
    • 0031863277 scopus 로고    scopus 로고
    • The natural history of debonding of the femoral component from the cement and its effect on long-term survival of Charnley total hip replacements
    • Berry D.J., Harmsen W.S., and Ilstrup D.M. The natural history of debonding of the femoral component from the cement and its effect on long-term survival of Charnley total hip replacements. J. Bone Joint Surg. Am. 80 (1998) 715-721
    • (1998) J. Bone Joint Surg. Am. , vol.80 , pp. 715-721
    • Berry, D.J.1    Harmsen, W.S.2    Ilstrup, D.M.3
  • 7
    • 0002465454 scopus 로고
    • Variations in shear strength of the bone-cement interface in the proximal femur
    • Bugbee W.D., Barrera D.L., Lee A.C., and Coventry F.R. Variations in shear strength of the bone-cement interface in the proximal femur. Trans. Orthop. Res. Soc. 17 (1992) 22
    • (1992) Trans. Orthop. Res. Soc. , vol.17 , pp. 22
    • Bugbee, W.D.1    Barrera, D.L.2    Lee, A.C.3    Coventry, F.R.4
  • 8
    • 0036528664 scopus 로고    scopus 로고
    • Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry
    • Collis D.K., and Mohler C.G. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J. Bone Joint Surg. Am. 84-A (2002) 586-592
    • (2002) J. Bone Joint Surg. Am. , vol.84 -A , pp. 586-592
    • Collis, D.K.1    Mohler, C.G.2
  • 9
    • 0027461703 scopus 로고
    • Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs
    • Dall D.M., Learmonth I.D., Solomon M.I., Miles A.W., and Davenport J.M. Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs. J. Bone Joint Surg. Br. 75 (1993) 259-265
    • (1993) J. Bone Joint Surg. Br. , vol.75 , pp. 259-265
    • Dall, D.M.1    Learmonth, I.D.2    Solomon, M.I.3    Miles, A.W.4    Davenport, J.M.5
  • 11
  • 12
    • 0028058237 scopus 로고
    • Failure of the cement-bone interface: a consequence of strengthening the cement-prosthesis interface?
    • Gardiner R.C., and Hozack W.J. Failure of the cement-bone interface: a consequence of strengthening the cement-prosthesis interface?. J. Bone Joint Surg. Br. 76 (1994) 49-52
    • (1994) J. Bone Joint Surg. Br. , vol.76 , pp. 49-52
    • Gardiner, R.C.1    Hozack, W.J.2
  • 13
    • 0026438865 scopus 로고
    • Is it advantageous to strengthen the cement-metal interface and use a collar for cemented components of total hip replacements
    • Harris W.H. Is it advantageous to strengthen the cement-metal interface and use a collar for cemented components of total hip replacements. Clin. Orthop. 285 (1992) 67-72
    • (1992) Clin. Orthop. , vol.285 , pp. 67-72
    • Harris, W.H.1
  • 14
    • 0031733352 scopus 로고    scopus 로고
    • Long-term results of cemented femoral stems with roughened precoated surfaces
    • Harris W.H. Long-term results of cemented femoral stems with roughened precoated surfaces. Clin. Orthop. Relat. Res. (1998) 137-143
    • (1998) Clin. Orthop. Relat. Res. , pp. 137-143
    • Harris, W.H.1
  • 15
    • 0001546191 scopus 로고
    • The brittle strength of orthotropic materials
    • Hoffman O.J. The brittle strength of orthotropic materials. Compos. Mater. 1 (1967) 200-206
    • (1967) Compos. Mater. , vol.1 , pp. 200-206
    • Hoffman, O.J.1
  • 16
    • 0031828375 scopus 로고    scopus 로고
    • Loosening of matt and polished cemented femoral stems
    • Howie D.W., Middleton R.G., and Costi K. Loosening of matt and polished cemented femoral stems. J. Bone Joint Surg. Br. 80 (1998) 573-576
    • (1998) J. Bone Joint Surg. Br. , vol.80 , pp. 573-576
    • Howie, D.W.1    Middleton, R.G.2    Costi, K.3
  • 19
    • 0242494220 scopus 로고    scopus 로고
    • The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses
    • Lennon A.B., McCormack B.A., and Prendergast P.J. The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses. Med. Eng. Phys. 25 (2003) 833-841
    • (2003) Med. Eng. Phys. , vol.25 , pp. 833-841
    • Lennon, A.B.1    McCormack, B.A.2    Prendergast, P.J.3
  • 22
    • 0032077696 scopus 로고    scopus 로고
    • Pre-yield and post-yield shear behavior of the cement-bone interface
    • Mann K.A., Allen M.J., and Ayers D.C. Pre-yield and post-yield shear behavior of the cement-bone interface. J. Orthop. Res. 16 (1998) 370-378
    • (1998) J. Orthop. Res. , vol.16 , pp. 370-378
    • Mann, K.A.1    Allen, M.J.2    Ayers, D.C.3
  • 24
    • 0034864341 scopus 로고    scopus 로고
    • Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis
    • Norman T.L., Thyagarajan G., Saligrama V.C., Gruen T.A., and Blaha J.D. Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis. J. Biomech. 34 (2001) 1325-1333
    • (2001) J. Biomech. , vol.34 , pp. 1325-1333
    • Norman, T.L.1    Thyagarajan, G.2    Saligrama, V.C.3    Gruen, T.A.4    Blaha, J.D.5
  • 26
    • 53649094100 scopus 로고    scopus 로고
    • Shear bonding strength of cement-bone interface under compression
    • Song H.N., Yoon Y.S., and Kil K.B. Shear bonding strength of cement-bone interface under compression. Proc. Korean Orthop. Res. Soc. 28 (2002) 5
    • (2002) Proc. Korean Orthop. Res. Soc. , vol.28 , pp. 5
    • Song, H.N.1    Yoon, Y.S.2    Kil, K.B.3
  • 27
    • 0033968681 scopus 로고    scopus 로고
    • Three-dimensional measurement of cemented femoral stem stability: an in vitro cadaver study
    • Speirs A.D., Slomczykowski M.A., Orr T.E., Siebenrock K., and Nolte L.P. Three-dimensional measurement of cemented femoral stem stability: an in vitro cadaver study. Clin. Biomech. 15 (2000) 248-255
    • (2000) Clin. Biomech. , vol.15 , pp. 248-255
    • Speirs, A.D.1    Slomczykowski, M.A.2    Orr, T.E.3    Siebenrock, K.4    Nolte, L.P.5
  • 28
    • 0032947562 scopus 로고    scopus 로고
    • The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than 50 years old
    • Sporer S.M., Callaghan J.J., Olejniczak J.P., Goetz D.D., and Johnston R.C. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than 50 years old. J. Bone Joint Surg. Am. 81 (1999) 481-492
    • (1999) J. Bone Joint Surg. Am. , vol.81 , pp. 481-492
    • Sporer, S.M.1    Callaghan, J.J.2    Olejniczak, J.P.3    Goetz, D.D.4    Johnston, R.C.5
  • 29
    • 0021085023 scopus 로고
    • Multiaxial strength characteristics of trabecular bone
    • Stone J.L., Beaupre G.S., and Hayes W.C. Multiaxial strength characteristics of trabecular bone. J. Biomech. 16 (1983) 743-752
    • (1983) J. Biomech. , vol.16 , pp. 743-752
    • Stone, J.L.1    Beaupre, G.S.2    Hayes, W.C.3
  • 30
    • 0141958922 scopus 로고    scopus 로고
    • A prospective randomized trial of cemented femoral components with polished versus grit-blasted surface finish and identical stem geometry
    • Vail T.P., Goetz D., Tanzer M., Fisher D.A., Mohler C.G., and Callaghan J.J. A prospective randomized trial of cemented femoral components with polished versus grit-blasted surface finish and identical stem geometry. J. Arthroplasty 18 (2003) 95-102
    • (2003) J. Arthroplasty , vol.18 , pp. 95-102
    • Vail, T.P.1    Goetz, D.2    Tanzer, M.3    Fisher, D.A.4    Mohler, C.G.5    Callaghan, J.J.6
  • 31
    • 0029790390 scopus 로고    scopus 로고
    • Mechanical effects of stem cement interface characteristics in total hip replacement
    • Verdonschot N., and Huiskes R. Mechanical effects of stem cement interface characteristics in total hip replacement. Clin. Orthop. Relat. Res. (1996) 326-336
    • (1996) Clin. Orthop. Relat. Res. , pp. 326-336
    • Verdonschot, N.1    Huiskes, R.2
  • 32
    • 0032192224 scopus 로고    scopus 로고
    • Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage
    • Verdonschot N., and Huiskes R. Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage. Biomaterials 19 (1998) 1773-1779
    • (1998) Biomaterials , vol.19 , pp. 1773-1779
    • Verdonschot, N.1    Huiskes, R.2
  • 33
    • 0027703693 scopus 로고
    • Quantitative analysis of bone reactions to relative motions at implant-bone interfaces
    • Weinans H., Huiskes R., and Grootenboer H.J. Quantitative analysis of bone reactions to relative motions at implant-bone interfaces. J. Biomech. 26 (1993) 1271-1281
    • (1993) J. Biomech. , vol.26 , pp. 1271-1281
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 34
    • 0030628145 scopus 로고    scopus 로고
    • The influence of the stem-cement interface in total hip replacement - a comparison of experimental and finite element approaches
    • Wheeler J.P., Miles A.W., and Clift S.E. The influence of the stem-cement interface in total hip replacement - a comparison of experimental and finite element approaches. Proc. Inst. Mech. Eng. 211 2 (1997) 181-186
    • (1997) Proc. Inst. Mech. Eng. , vol.211 , Issue.2 , pp. 181-186
    • Wheeler, J.P.1    Miles, A.W.2    Clift, S.E.3
  • 35
    • 0035216886 scopus 로고    scopus 로고
    • Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience
    • Wroblewski B.M., Siney P.D., and Fleming P.A. Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience. J. Arthroplasty 16 (2001) 37-41
    • (2001) J. Arthroplasty , vol.16 , pp. 37-41
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.