메뉴 건너뛰기




Volumn 466, Issue 10, 2008, Pages 2482-2490

Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ADULT; AGED; ARTICLE; BONE TRANSPLANTATION; FEMALE; HIP ARTHROPLASTY; HUMAN; INFECTIOUS ARTHRITIS; JOINT FUNCTION; JOINT PROSTHESIS; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS MATERIAL; REIMPLANTATION; SURVIVAL RATE; CEMENTATION; CLINICAL TRIAL; EQUIPMENT DESIGN; HIP PROSTHESIS; INSTRUMENTATION; MIDDLE AGED; PROSPECTIVE STUDY; PROSTHESIS; RADIOGRAPHY; SURGICAL EQUIPMENT; TREATMENT OUTCOME;

EID: 52649131439     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-008-0442-x     Document Type: Article
Times cited : (73)

References (56)
  • 1
    • 0022489328 scopus 로고
    • Anteversion of the acetabular cup: Measurement of angle after total hip replacement
    • MK Ackland WB Bourne HK Uhthoff 1986 Anteversion of the acetabular cup: measurement of angle after total hip replacement J Bone Joint Surg Br. 68 409 413
    • (1986) J Bone Joint Surg Br. , vol.68 , pp. 409-413
    • Ackland, M.K.1    Bourne, W.B.2    Uhthoff, H.K.3
  • 2
    • 0027969296 scopus 로고
    • Compressed allograft chips for acetabular reconstruction in revision hip arthroplasty
    • T Azuma H Yasuda K Okagaki K Sakai 1994 Compressed allograft chips for acetabular reconstruction in revision hip arthroplasty J Bone Joint Surg Br. 76 740 744
    • (1994) J Bone Joint Surg Br. , vol.76 , pp. 740-744
    • Azuma, T.1    Yasuda, H.2    Okagaki, K.3    Sakai, K.4
  • 3
    • 0026785585 scopus 로고
    • Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency
    • DJ Berry ME Muller 1992 Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency J Bone Joint Surg Br. 74 711 715
    • (1992) J Bone Joint Surg Br. , vol.74 , pp. 711-715
    • Berry, D.J.1    Muller, M.E.2
  • 5
    • 2942733419 scopus 로고    scopus 로고
    • Wire mesh allows more revascularization than a strut in impaction bone grafting: An animal study in goats
    • SB Bolder BW Schreurs N Verdonschot RP Veth P Buma 2004 Wire mesh allows more revascularization than a strut in impaction bone grafting: an animal study in goats Clin Orthop Relat Res. 423 280 286
    • (2004) Clin Orthop Relat Res. , vol.423 , pp. 280-286
    • Bolder, S.B.1    Schreurs, B.W.2    Verdonschot, N.3    Veth, R.P.4    Buma, P.5
  • 6
    • 0035212282 scopus 로고    scopus 로고
    • Revision total hip arthroplasty using impaction bone grafting with cemented nonpolished stems and Charnley cups
    • JG Boldt P Dilawari S Agarwal KJ Drabu 2001 Revision total hip arthroplasty using impaction bone grafting with cemented nonpolished stems and Charnley cups J Arthroplasty. 16 943 952
    • (2001) J Arthroplasty. , vol.16 , pp. 943-952
    • Boldt, J.G.1    Dilawari, P.2    Agarwal, S.3    Drabu, K.J.4
  • 7
    • 39749201530 scopus 로고    scopus 로고
    • Viability of impacted bone allografts under calcar metal mesh in revision surgery of the hip: Case report
    • M Buttaro GS Araujo ES Araujo F Comba F Piccaluga 2008 Viability of impacted bone allografts under calcar metal mesh in revision surgery of the hip: case report J Bone Joint Surg Br. 90 228 231
    • (2008) J Bone Joint Surg Br. , vol.90 , pp. 228-231
    • Buttaro, M.1    Araujo, G.S.2    Araujo, E.S.3    Comba, F.4    Piccaluga, F.5
  • 8
    • 33745948305 scopus 로고    scopus 로고
    • Acetabular reconstruction with impacted bone allografts and cemented acetabular components: A 2- to 13-year follow-up study of 142 aseptic revisions
    • F Comba M Buttaro R Pusso F Piccaluga 2006 Acetabular reconstruction with impacted bone allografts and cemented acetabular components: a 2- to 13-year follow-up study of 142 aseptic revisions J Bone Joint Surg Br. 88 865 869
    • (2006) J Bone Joint Surg Br. , vol.88 , pp. 865-869
    • Comba, F.1    Buttaro, M.2    Pusso, R.3    Piccaluga, F.4
  • 9
    • 53649095375 scopus 로고    scopus 로고
    • Acetabular revision surgery with impacted bone allografts and cemented cups in patients younger than 55 years
    • Feb 9 [Epub ahead of print].
    • Comba F, Buttaro M, Pusso R, Piccaluga F. Acetabular revision surgery with impacted bone allografts and cemented cups in patients younger than 55 years. Int Orthop. 2008 Feb 9 [Epub ahead of print].
    • (2008) Int Orthop
    • Comba, F.1    Buttaro, M.2    Pusso, R.3    Piccaluga, F.4
  • 11
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • RM D'Aubigné M Postel 1954 Functional results of hip arthroplasty with acrylic prosthesis J Bone Joint Surg Am. 36 451 475
    • (1954) J Bone Joint Surg Am. , vol.36 , pp. 451-475
    • D'Aubigné, R.M.1    Postel, M.2
  • 12
    • 0032900593 scopus 로고    scopus 로고
    • High placement of an acetabular component inserted without cement in a revision total hip arthroplasty: Results after a mean of ten years
    • JT Dearborn WH Harris 1999 High placement of an acetabular component inserted without cement in a revision total hip arthroplasty: results after a mean of ten years J Bone Joint Surg Am. 81 469 480
    • (1999) J Bone Joint Surg Am. , vol.81 , pp. 469-480
    • Dearborn, J.T.1    Harris, W.H.2
  • 13
    • 0033976449 scopus 로고    scopus 로고
    • Acetabular revision arthroplasty using so-called jumbo cementless components: An average 7-year follow-up study
    • JT Dearborn WH Harris 2000 Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study J Arthroplasty. 15 8 15
    • (2000) J Arthroplasty. , vol.15 , pp. 8-15
    • Dearborn, J.T.1    Harris, W.H.2
  • 14
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • JG DeLee J Charnley 1976 Radiological demarcation of cemented sockets in total hip replacement Clin Orthop Relat Res. 121 20 32
    • (1976) Clin Orthop Relat Res. , vol.121 , pp. 20-32
    • Delee, J.G.1    Charnley, J.2
  • 15
    • 0004262975 scopus 로고
    • American Association of Tissue Banks McLean, VA
    • Fawcett K, Barr AR. Tissue Banking. McLean, VA: American Association of Tissue Banks; 1987.
    • (1987) Tissue Banking
    • Fawcett, K.1    Barr, A.R.2
  • 17
    • 0031593621 scopus 로고    scopus 로고
    • The Burch-Schneider anti-protrusio cage in revision total hip arthroplasty: Indications, principles and long-term results
    • TJ Gill JB Sledge ME Muller 1998 The Burch-Schneider anti-protrusio cage in revision total hip arthroplasty: indications, principles and long-term results J Bone Joint Surg Br. 80 946 953
    • (1998) J Bone Joint Surg Br. , vol.80 , pp. 946-953
    • Gill, T.J.1    Sledge, J.B.2    Muller, M.E.3
  • 18
    • 2642532712 scopus 로고    scopus 로고
    • Complications of ilioischial reconstruction rings in revision total hip arthroplasty
    • S Goodman H Saastamoinen N Shasha A Gross 2004 Complications of ilioischial reconstruction rings in revision total hip arthroplasty J Arthroplasty. 19 436 446
    • (2004) J Arthroplasty. , vol.19 , pp. 436-446
    • Goodman, S.1    Saastamoinen, H.2    Shasha, N.3    Gross, A.4
  • 19
    • 0023810920 scopus 로고
    • Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening
    • RB Gustilo HS Pasternak 1988 Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening Clin Orthop Relat Res. 235 111 119
    • (1988) Clin Orthop Relat Res. , vol.235 , pp. 111-119
    • Gustilo, R.B.1    Pasternak, H.S.2
  • 20
    • 0020061476 scopus 로고
    • Allografting in total hip arthroplasty: In adults with severe acetabular deficiency including a surgical technique for bolting the graft to the ilium
    • WH Harris 1982 Allografting in total hip arthroplasty: in adults with severe acetabular deficiency including a surgical technique for bolting the graft to the ilium Clin Orthop Relat Res. 162 150 164
    • (1982) Clin Orthop Relat Res. , vol.162 , pp. 150-164
    • Harris, W.H.1
  • 21
    • 0016669712 scopus 로고
    • The use of wire mesh in total hip replacement surgery
    • WH Harris WN Jones 1975 The use of wire mesh in total hip replacement surgery Clin Orthop Relat Res. 106 117 121
    • (1975) Clin Orthop Relat Res. , vol.106 , pp. 117-121
    • Harris, W.H.1    Jones, W.N.2
  • 22
    • 0031596599 scopus 로고    scopus 로고
    • Jumbo cups and morsalized graft
    • M Jasty 1998 Jumbo cups and morsalized graft Orthop Clin North Am. 29 249 254
    • (1998) Orthop Clin North Am. , vol.29 , pp. 249-254
    • Jasty, M.1
  • 23
    • 0024203921 scopus 로고
    • Results of total hip reconstruction using acetabular mesh in patients with central acetabular deficiency
    • M Jasty WH Harris 1988 Results of total hip reconstruction using acetabular mesh in patients with central acetabular deficiency Clin Orthop Relat Res. 237 142 149
    • (1988) Clin Orthop Relat Res. , vol.237 , pp. 142-149
    • Jasty, M.1    Harris, W.H.2
  • 24
    • 0025099128 scopus 로고
    • Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts
    • M Jasty WH Harris 1990 Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts J Bone Joint Surg Br. 72 63 67
    • (1990) J Bone Joint Surg Br. , vol.72 , pp. 63-67
    • Jasty, M.1    Harris, W.H.2
  • 25
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • E Kaplan P Meier 1958 Nonparametric estimation from incomplete observations J Am Stat Assoc. 53 457 481
    • (1958) J Am Stat Assoc. , vol.53 , pp. 457-481
    • Kaplan, E.1    Meier, P.2
  • 26
    • 0030898026 scopus 로고    scopus 로고
    • Long-term results of revision total hip arthroplasty with improved cementing technique
    • RP Katz JJ Callaghan PM Sullivan RC Johnston 1997 Long-term results of revision total hip arthroplasty with improved cementing technique J Bone Joint Surg Br. 79 322 326
    • (1997) J Bone Joint Surg Br. , vol.79 , pp. 322-326
    • Katz, R.P.1    Callaghan, J.J.2    Sullivan, P.M.3    Johnston, R.C.4
  • 27
    • 0028042344 scopus 로고
    • High hip center in revision arthroplasty
    • SS Kelley 1994 High hip center in revision arthroplasty J Arthroplasty. 9 503 510
    • (1994) J Arthroplasty. , vol.9 , pp. 503-510
    • Kelley, S.S.1
  • 28
    • 0033852227 scopus 로고    scopus 로고
    • The Kerboull acetabular reinforcement device in major acetabular reconstructions
    • M Kerboull M Hamadouche L Kerboull 2000 The Kerboull acetabular reinforcement device in major acetabular reconstructions Clin Orthop Relat Res. 378 155 168
    • (2000) Clin Orthop Relat Res. , vol.378 , pp. 155-168
    • Kerboull, M.1    Hamadouche, M.2    Kerboull, L.3
  • 29
    • 0031851235 scopus 로고    scopus 로고
    • An oblong revision cup for large acetabular defects: Design rationale and two- to seven-year follow-up
    • G Koster HG Willert HP Kohler K Dopkens 1998 An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up J Arthroplasty. 13 559 569
    • (1998) J Arthroplasty. , vol.13 , pp. 559-569
    • Koster, G.1    Willert, H.G.2    Kohler, H.P.3    Dopkens, K.4
  • 30
    • 2542542518 scopus 로고
    • Titanium, a metal for surgery
    • GS Levinthal 1951 Titanium, a metal for surgery J Bone Joint Surg Am. 33 473 474
    • (1951) J Bone Joint Surg Am. , vol.33 , pp. 473-474
    • Levinthal, G.S.1
  • 31
    • 0013959192 scopus 로고
    • Mandibular fractures: Metallic implant fixation using vitallium mesh
    • MW Lockey GW Hahn DA Corgill 1966 Mandibular fractures: metallic implant fixation using vitallium mesh Arch Otolaryngol. 84 451 456
    • (1966) Arch Otolaryngol. , vol.84 , pp. 451-456
    • Lockey, M.W.1    Hahn, G.W.2    Corgill, D.A.3
  • 32
    • 0003690671 scopus 로고
    • American Association of Tissue Banks Arlington, VA
    • Mowe JC. Standards for Tissue Banking. Arlington, VA: American Association of Tissue Banks; 1988.
    • (1988) Standards for Tissue Banking
    • Mowe, J.C.1
  • 33
    • 9644270215 scopus 로고    scopus 로고
    • Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty
    • A Nehme DG Lewallen AD Hanssen 2004 Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty Clin Orthop Relat Res. 429 201 208
    • (2004) Clin Orthop Relat Res. , vol.429 , pp. 201-208
    • Nehme, A.1    Lewallen, D.G.2    Hanssen, A.D.3
  • 34
    • 34247586047 scopus 로고    scopus 로고
    • Frozen sections of samples taken intraoperatively for diagnosis of infection in revision hip surgery
    • LV Nunez MA Buttaro A Morandi R Pusso F Piccaluga 2007 Frozen sections of samples taken intraoperatively for diagnosis of infection in revision hip surgery Acta Orthop. 78 226 230
    • (2007) Acta Orthop. , vol.78 , pp. 226-230
    • Nunez, L.V.1    Buttaro, M.A.2    Morandi, A.3    Pusso, R.4    Piccaluga, F.5
  • 35
    • 33749266151 scopus 로고    scopus 로고
    • Five-year follow-up of socket movements and loosening after revision with impacted morselized allograft bone and cement: A radiostereometric and radiographic analysis
    • E Ornstein H Franzen R Johnsson A Stefansdottir M Sundberg M Tagil 2006 Five-year follow-up of socket movements and loosening after revision with impacted morselized allograft bone and cement: a radiostereometric and radiographic analysis J Arthroplasty. 21 975 984
    • (2006) J Arthroplasty. , vol.21 , pp. 975-984
    • Ornstein, E.1    Franzen, H.2    Johnsson, R.3    Stefansdottir, A.4    Sundberg, M.5    Tagil, M.6
  • 37
    • 0036265808 scopus 로고    scopus 로고
    • Revision of the femoral prosthesis with impaction allografting and a Charnley stem: A 2- to 12-year follow-up
    • F Piccaluga A Gonzalez Della Valle JC Encinas Fernandez R Pusso 2002 Revision of the femoral prosthesis with impaction allografting and a Charnley stem: a 2- to 12-year follow-up J Bone Joint Surg Br. 84 544 549
    • (2002) J Bone Joint Surg Br. , vol.84 , pp. 544-549
    • Piccaluga, F.1    Gonzalez Della Valle, A.2    Encinas Fernandez, J.C.3    Pusso, R.4
  • 38
    • 0038605722 scopus 로고    scopus 로고
    • The role of stainless steel wire mesh and cement in bone allograft incorporation in impaction grafting technique: An experimental study in rabbits
    • N Roidis T Karachalios L Khaldi K Stamos GP Lyritis 2003 The role of stainless steel wire mesh and cement in bone allograft incorporation in impaction grafting technique: an experimental study in rabbits J Arthroplasty. 18 484 493
    • (2003) J Arthroplasty. , vol.18 , pp. 484-493
    • Roidis, N.1    Karachalios, T.2    Khaldi, L.3    Stamos, K.4    Lyritis, G.P.5
  • 39
    • 0033854691 scopus 로고    scopus 로고
    • Impacted morsellized bone grafting and cemented primary total hip arthroplasty for acetabular protrusion in patients with rheumatoid arthritis: An 8- to 18-year follow-up study of 36 hips
    • WW Rosenberg BW Schreurs MC l Malefijt RP Veth TJ Slooff 2000 Impacted morsellized bone grafting and cemented primary total hip arthroplasty for acetabular protrusion in patients with rheumatoid arthritis: an 8- to 18-year follow-up study of 36 hips Acta Orthop Scand. 71 143 146
    • (2000) Acta Orthop Scand. , vol.71 , pp. 143-146
    • Rosenberg, W.W.1    Schreurs, B.W.2    Malefijt M C, L.3    Veth, R.P.4    Slooff, T.J.5
  • 40
    • 0026795485 scopus 로고
    • The use of reinforcement rings to reconstruct deficient acetabula
    • J Rosson J Schatzker 1992 The use of reinforcement rings to reconstruct deficient acetabula J Bone Joint Surg Br. 74 716 720
    • (1992) J Bone Joint Surg Br. , vol.74 , pp. 716-720
    • Rosson, J.1    Schatzker, J.2
  • 41
    • 0020858724 scopus 로고
    • Stiffness and inelastic deformation in acrylic titanium composite implant materials under compression
    • DS Schnur D Lee 1983 Stiffness and inelastic deformation in acrylic titanium composite implant materials under compression J Biomed Mater Res. 17 973 991
    • (1983) J Biomed Mater Res. , vol.17 , pp. 973-991
    • Schnur, D.S.1    Lee, D.2
  • 44
    • 0035181076 scopus 로고    scopus 로고
    • Acetabular reconstruction with bone impaction grafting and a cemented cup: 20 years' experience
    • BW Schreurs TJ Slooff JW Gardeniers P Buma 2001 Acetabular reconstruction with bone impaction grafting and a cemented cup: 20 years' experience Clin Orthop Relat Res. 393 202 215
    • (2001) Clin Orthop Relat Res. , vol.393 , pp. 202-215
    • Schreurs, B.W.1    Slooff, T.J.2    Gardeniers, J.W.3    Buma, P.4
  • 45
    • 0028040956 scopus 로고
    • High placement of porous-coated acetabular components in complex total hip arthroplasty
    • SF Schutzer WH Harris 1994 High placement of porous-coated acetabular components in complex total hip arthroplasty J Arthroplasty. 9 359 367
    • (1994) J Arthroplasty. , vol.9 , pp. 359-367
    • Schutzer, S.F.1    Harris, W.H.2
  • 46
    • 0031017797 scopus 로고    scopus 로고
    • Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty: Sixteen-year-average follow-up
    • AA Shinar WH Harris 1997 Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty: sixteen-year-average follow-up J Bone Joint Surg Am. 79 159 168
    • (1997) J Bone Joint Surg Am. , vol.79 , pp. 159-168
    • Shinar, A.A.1    Harris, W.H.2
  • 47
    • 0029793627 scopus 로고    scopus 로고
    • Revision of the acetabular component without cement after total hip arthroplasty: A follow-up note regarding results at seven to eleven years
    • CD Silverton AG Rosenberg MB Sheinkop LR Kull JO Galante 1996 Revision of the acetabular component without cement after total hip arthroplasty: a follow-up note regarding results at seven to eleven years J Bone Joint Surg Am. 78 1366 1370
    • (1996) J Bone Joint Surg Am. , vol.78 , pp. 1366-1370
    • Silverton, C.D.1    Rosenberg, A.G.2    Sheinkop, M.B.3    Kull, L.R.4    Galante, J.O.5
  • 50
    • 0017619864 scopus 로고
    • Tensile strength of wire-reinforced bone cement and twisted stainless-steel wire
    • JP Taitsman S Saha 1977 Tensile strength of wire-reinforced bone cement and twisted stainless-steel wire J Bone Joint Surg Am. 59 419 425
    • (1977) J Bone Joint Surg Am. , vol.59 , pp. 419-425
    • Taitsman, J.P.1    Saha, S.2
  • 51
    • 0035181442 scopus 로고    scopus 로고
    • Revision of a cemented acetabular component to a cementless acetabular component: A ten to fourteen-year follow-up study
    • JE Templeton JJ Callaghan DD Goetz PM Sullivan RC Johnston 2001 Revision of a cemented acetabular component to a cementless acetabular component: a ten to fourteen-year follow-up study J Bone Joint Surg Am. 83 1706 1711
    • (2001) J Bone Joint Surg Am. , vol.83 , pp. 1706-1711
    • Templeton, J.E.1    Callaghan, J.J.2    Goetz, D.D.3    Sullivan, P.M.4    Johnston, R.C.5
  • 52
    • 0022484213 scopus 로고
    • Allograft reconstruction of the acetabulum during revision total hip arthroplasty: Clinical, radiographic, and scintigraphic assessment of the results
    • TM Trancik BN Stulberg AH Wilde DH Feiglin 1986 Allograft reconstruction of the acetabulum during revision total hip arthroplasty: clinical, radiographic, and scintigraphic assessment of the results J Bone Joint Surg Am. 68 527 533
    • (1986) J Bone Joint Surg Am. , vol.68 , pp. 527-533
    • Trancik, T.M.1    Stulberg, B.N.2    Wilde, A.H.3    Feiglin, D.H.4
  • 55
    • 0033766450 scopus 로고    scopus 로고
    • Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: A 10- to 17-year follow-up study
    • ML Welten BW Schreurs P Buma N Verdonschot TJ Slooff 2000 Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: a 10- to 17-year follow-up study J Arthroplasty. 15 819 824
    • (2000) J Arthroplasty. , vol.15 , pp. 819-824
    • Welten, M.L.1    Schreurs, B.W.2    Buma, P.3    Verdonschot, N.4    Slooff, T.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.