메뉴 건너뛰기




Volumn , Issue , 2008, Pages 844-849

Control of a mock circulatory system to simulate the short-term baroreflex

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURES; BAROREFLEX; CIRCULATORY SYSTEMS;

EID: 52449132143     PISSN: 07431619     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ACC.2008.4586598     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 2
    • 0034744380 scopus 로고    scopus 로고
    • Elastance-based control of a Mock Circulatory System
    • L.A. Baloa, J.R. Boston, and J.F. Antaki, "Elastance-based control of a Mock Circulatory System," Annals Biomed. Eng., vol. 29, 2001, pp 244-251.
    • (2001) Annals Biomed. Eng , vol.29 , pp. 244-251
    • Baloa, L.A.1    Boston, J.R.2    Antaki, J.F.3
  • 3
    • 27744465023 scopus 로고    scopus 로고
    • A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices
    • D. Timms, M. Hayne, K. McNeil, and A. Galbraith, "A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices," Artificial Organs vol. 29(7), 2005, pp 564-572.
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 564-572
    • Timms, D.1    Hayne, M.2    McNeil, K.3    Galbraith, A.4
  • 5
    • 33750694324 scopus 로고    scopus 로고
    • Interaction between carotid baroregulation and the pulsating heart: A mathematical model
    • Nov
    • M. Ursino, "Interaction between carotid baroregulation and the pulsating heart: a mathematical model", Am. J. Physiol, Heart Circ. Physiol, Nov 1998; 275: H1733-1747.
    • (1998) Am. J. Physiol, Heart Circ. Physiol , vol.275
    • Ursino, M.1
  • 6
    • 0036081823 scopus 로고    scopus 로고
    • Theoretical analysis of rest and exercise haemodynamics in patients with total cavopulmondary connection
    • Mar
    • E. Magosso, S. Cavalcanti, and M. Ursino, "Theoretical analysis of rest and exercise haemodynamics in patients with total cavopulmondary connection," Am. J. Physiol Heart. Circ. Physiol, Mar 2002; 282: H1018-H1034.
    • (2002) Am. J. Physiol Heart. Circ. Physiol , vol.282
    • Magosso, E.1    Cavalcanti, S.2    Ursino, M.3
  • 8
    • 33751101623 scopus 로고    scopus 로고
    • Evaluation of a Simple Cardiovascular Model with the Short Term Baroreflex
    • Easton, PA
    • nd Northeast Bioeng. Conf., Easton, PA, 2006, pp. 151-152.
    • (2006) nd Northeast Bioeng. Conf , pp. 151-152
    • Mushi, S.1    Yu, Y.C.2
  • 9
    • 23944488731 scopus 로고    scopus 로고
    • Model-based Prediction of a Percutaneous Ventricular Assist Device Performance
    • Y.C. Yu, M.A. Simaan, N.V. Zorn, and S. Mushi, "Model-based Prediction of a Percutaneous Ventricular Assist Device Performance," Proc. Am. Control Conf., 2005 pp 3835-3840.
    • (2005) Proc. Am. Control Conf , pp. 3835-3840
    • Yu, Y.C.1    Simaan, M.A.2    Zorn, N.V.3    Mushi, S.4
  • 10
    • 52449125886 scopus 로고    scopus 로고
    • Regulation of arterial pressure; Cardiovascular responses to physiological stress
    • Cardiovascular Physiology, 5th Edition, McGraw-Hill Companies
    • th Edition. Lange Physiology Series, McGraw-Hill Companies, 2003.
    • (2003) Lange Physiology Series
    • Mohrman, D.1    Heller, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.