-
1
-
-
0034181041
-
A prototype neural semicircular canal prosthesis using patterned electrical stimulation
-
W. Gong and D. Merfeld, "A prototype neural semicircular canal prosthesis using patterned electrical stimulation," Ann. Biomed. Eng., vol. 28, pp. 572-581, 2000.
-
(2000)
Ann. Biomed. Eng
, vol.28
, pp. 572-581
-
-
Gong, W.1
Merfeld, D.2
-
2
-
-
31544435478
-
An electronic prosthesis mimicking the dynamic vestibular function
-
A. M. Shkel and F.-G. Zeng, "An electronic prosthesis mimicking the dynamic vestibular function," Audiol. Neurotol., vol. 11, pp. 113-122, 2006.
-
(2006)
Audiol. Neurotol
, vol.11
, pp. 113-122
-
-
Shkel, A.M.1
Zeng, F.-G.2
-
3
-
-
34249314396
-
A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-D vestibular sensation
-
Jun
-
C. C. Della Santina, A. A. Migliaccio, and A. H. Patel, "A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-D vestibular sensation," IEEE Trans. Biomed. Eng., vol. 54, no. 6, pp. 1016-1030, Jun. 2007.
-
(2007)
IEEE Trans. Biomed. Eng
, vol.54
, Issue.6
, pp. 1016-1030
-
-
Della Santina, C.C.1
Migliaccio, A.A.2
Patel, A.H.3
-
4
-
-
23844471959
-
Functional electrical stimulation for neuromuscular applications
-
P. H. Peckham and J. S. Knuston, "Functional electrical stimulation for neuromuscular applications," Ann. Rev. Biomed. Eng., no. 3, pp. 327-360, 2005.
-
(2005)
Ann. Rev. Biomed. Eng
, Issue.3
, pp. 327-360
-
-
Peckham, P.H.1
Knuston, J.S.2
-
5
-
-
0020041298
-
Monopolar versus bipolar stimulation
-
P. Comte, "Monopolar versus bipolar stimulation," Stereotactic and Functional Neurosurgery, vol. 45, no. 1-2, pp. 156-159, 1982.
-
(1982)
Stereotactic and Functional Neurosurgery
, vol.45
, Issue.1-2
, pp. 156-159
-
-
Comte, P.1
-
6
-
-
33646462467
-
Effect of electrode configuration on psychophysical forward masking in cochlear implant listeners
-
B. J. Kwon and C. Van den Honert, "Effect of electrode configuration on psychophysical forward masking in cochlear implant listeners," J. Acoust.Soc. Amer., vol. 119, no. 5, pp. 2994-3002, 2006.
-
(2006)
J. Acoust.Soc. Amer
, vol.119
, Issue.5
, pp. 2994-3002
-
-
Kwon, B.J.1
Van den Honert, C.2
-
7
-
-
34548813363
-
An experimental study of voltage, current, and charge controlled stimulation front-end circuitry
-
J. Simpson and M. Ghovanloo, "An experimental study of voltage, current, and charge controlled stimulation front-end circuitry," in Proc. IEEE Int. Symp. on Circuits Syst., 2007, pp. 325-328.
-
(2007)
Proc. IEEE Int. Symp. on Circuits Syst
, pp. 325-328
-
-
Simpson, J.1
Ghovanloo, M.2
-
8
-
-
0000694831
-
Brief, noninjurious electric waveform stimulation of the brain
-
J. C. Lilly, J. R. Hughes, E. C. Alvord, and T. W. Galkin, "Brief, noninjurious electric waveform stimulation of the brain," Science vol. 121, no. 3144, pp. 468-469, 1955.
-
(1955)
Science
, vol.121
, Issue.3144
, pp. 468-469
-
-
Lilly, J.C.1
Hughes, J.R.2
Alvord, E.C.3
Galkin, T.W.4
-
9
-
-
0034829727
-
Analysis of monophasic and biphasic electrical stimulation of nerve
-
J. T. Rubinstein, C. A. Miller, H. Mino, and P. J. Abbas, "Analysis of monophasic and biphasic electrical stimulation of nerve," IEEE Trans. Biomed. Eng., vol. 48, no. 10, pp. 1065-1070, 2001.
-
(2001)
IEEE Trans. Biomed. Eng
, vol.48
, Issue.10
, pp. 1065-1070
-
-
Rubinstein, J.T.1
Miller, C.A.2
Mino, H.3
Abbas, P.J.4
-
10
-
-
33748997809
-
An Implantable Stimulation for Selective Stimulation of Nerves,
-
PhD thesis, University College London
-
B. M. Bugbee, "An Implantable Stimulation for Selective Stimulation of Nerves," PhD thesis, University College London, 2000.
-
(2000)
-
-
Bugbee, B.M.1
-
11
-
-
33747048422
-
Asymmetric pulses in cochlear implants: Effects of pulse shape, polarity, and rate
-
O. Macherey, A. van Wieringen, R. P. Carlyon, J. M. Deeks, and J. Wouters, "Asymmetric pulses in cochlear implants: Effects of pulse shape, polarity, and rate," J. Assoc. for Res. in Otolaryngol., vol. 7, no. 3, pp. 253-266, 2006.
-
(2006)
J. Assoc. for Res. in Otolaryngol
, vol.7
, Issue.3
, pp. 253-266
-
-
Macherey, O.1
van Wieringen, A.2
Carlyon, R.P.3
Deeks, J.M.4
Wouters, J.5
-
12
-
-
34548739001
-
Towards an implantable vestibular prosthesis: The surgical challenges
-
T. G. Constandinou, J. Georgiou, C. C. Doumanidis, and C. Toumazou, "Towards an implantable vestibular prosthesis: The surgical challenges," in Proc. IEEE EMBS Conf. on Neural Eng., 2007, pp. 40-43.
-
(2007)
Proc. IEEE EMBS Conf. on Neural Eng
, pp. 40-43
-
-
Constandinou, T.G.1
Georgiou, J.2
Doumanidis, C.C.3
Toumazou, C.4
-
13
-
-
0028746879
-
A programmable electronic stimulator for FES systems
-
Dec
-
M. Illic, D. Vasiljevic, and D. B. Popovic, "A programmable electronic stimulator for FES systems," IEEE Trans. Rehab. Eng., vol. 2, no. 4, pp. 234-239, Dec. 1994.
-
(1994)
IEEE Trans. Rehab. Eng
, vol.2
, Issue.4
, pp. 234-239
-
-
Illic, M.1
Vasiljevic, D.2
Popovic, D.B.3
-
14
-
-
0031294265
-
A modular multichannel stimulator for arbitrary shaped current pulses for experimental and clinical use in FES
-
T. Stieglitz, T. Matal, and M. Staemmler, "A modular multichannel stimulator for arbitrary shaped current pulses for experimental and clinical use in FES," in Proc. IEEE Int. Conf. of EMBS, 1997, pp. 1777-1780.
-
(1997)
Proc. IEEE Int. Conf. of EMBS
, pp. 1777-1780
-
-
Stieglitz, T.1
Matal, T.2
Staemmler, M.3
-
15
-
-
17544389391
-
An implantable mixed analog/digital neural stimulator circuit
-
G. Gudnason, E. Bruun, and M. Haugland, "An implantable mixed analog/digital neural stimulator circuit," in Proc. IEEE Int. Symp. on Circuits Syst., 1999, vol. 5, pp. 375-378.
-
(1999)
Proc. IEEE Int. Symp. on Circuits Syst
, vol.5
, pp. 375-378
-
-
Gudnason, G.1
Bruun, E.2
Haugland, M.3
-
16
-
-
0032979662
-
Electronic design of a multichannel programmable implant for neuromuscular electrical stimulation
-
K. Arabi and M. A. Sawan, "Electronic design of a multichannel programmable implant for neuromuscular electrical stimulation," IEEE Trans. Rehab. Eng., vol. 7, no. 2, pp. 204-214, 1999.
-
(1999)
IEEE Trans. Rehab. Eng
, vol.7
, Issue.2
, pp. 204-214
-
-
Arabi, K.1
Sawan, M.A.2
-
17
-
-
11144324907
-
A novel system design for implantable stimulator application
-
C.-W. Chang, W.-Y. Chung, C.-C. Chuang, R.-L. Wei, and J.-X. Dai, "A novel system design for implantable stimulator application," in Proc. IEEE Int. Conf. EMBS, 2004, pp. 4107-4110.
-
(2004)
Proc. IEEE Int. Conf. EMBS
, pp. 4107-4110
-
-
Chang, C.-W.1
Chung, W.-Y.2
Chuang, C.-C.3
Wei, R.-L.4
Dai, J.-X.5
-
18
-
-
31644433354
-
A multiparameter implantable microstimulator SOC
-
Dec
-
C.-C. Wang, T.-J. Lee, Y.-T. Hsiao, U. F. Chio, C.-C. Huang, J.-J. J. Chin, and Y.-H. Hsueh, "A multiparameter implantable microstimulator SOC," IEEE Trans. Very Large Scale Integr. (VLSI) Syst., vol. 13, no. 12, pp. 1399-1402, Dec. 2005.
-
(2005)
IEEE Trans. Very Large Scale Integr. (VLSI) Syst
, vol.13
, Issue.12
, pp. 1399-1402
-
-
Wang, C.-C.1
Lee, T.-J.2
Hsiao, Y.-T.3
Chio, U.F.4
Huang, C.-C.5
Chin, J.-J.J.6
Hsueh, Y.-H.7
-
19
-
-
16244368094
-
An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC
-
Mar
-
M. Sivaprakasam, W. Liu, M. S. Humayun, and J. D. Weiland, "An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC," IEEE J. Solid-State Circuits, vol. 40, no. 3, pp. 763-771, Mar. 2005.
-
(2005)
IEEE J. Solid-State Circuits
, vol.40
, Issue.3
, pp. 763-771
-
-
Sivaprakasam, M.1
Liu, W.2
Humayun, M.S.3
Weiland, J.D.4
-
20
-
-
39849104171
-
A highly flexible system for microstimulation of the visual cortex: Design and implementation
-
Dec
-
J. Couloumbe, M. Sawan, and J.-F. Gervais, "A highly flexible system for microstimulation of the visual cortex: Design and implementation," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 4, pp. 258-269, Dec. 2007.
-
(2007)
IEEE Trans. Biomed. Circuits Syst
, vol.1
, Issue.4
, pp. 258-269
-
-
Couloumbe, J.1
Sawan, M.2
Gervais, J.-F.3
-
21
-
-
52249106077
-
A 232-channel epiretinal stimulator ASIC
-
Dec
-
M. Ortmanns, A. Rocke, M. Gehrke, and H.-J. Tiedtke, "A 232-channel epiretinal stimulator ASIC," IEEE J. Solid-State Circuits, vol. 42, no. 12, pp. 2946-2959, Dec. 2007.
-
(2007)
IEEE J. Solid-State Circuits
, vol.42
, Issue.12
, pp. 2946-2959
-
-
Ortmanns, M.1
Rocke, A.2
Gehrke, M.3
Tiedtke, H.-J.4
-
22
-
-
34548759067
-
Towards a reconfigurable sense-and-stimulate neural interface generating biphasic interleaved stimulus
-
A. Eftekhar, T. G. Constandinou, I. F. Triantis, C. Toumazou, and E. M. Drakakis, "Towards a reconfigurable sense-and-stimulate neural interface generating biphasic interleaved stimulus," in Proc. IEEE EMBS Conf. Neural Eng., 2007, vol. 3, pp. 438-441.
-
(2007)
Proc. IEEE EMBS Conf. Neural Eng
, vol.3
, pp. 438-441
-
-
Eftekhar, A.1
Constandinou, T.G.2
Triantis, I.F.3
Toumazou, C.4
Drakakis, E.M.5
-
23
-
-
34247609299
-
Using current steering to increase spectral resolution in CII and HiRes 90 K users
-
D. B. Koch, M. Downing, M. J. Osberger, and L. Litvak, "Using current steering to increase spectral resolution in CII and HiRes 90 K users," AAS Ear and Hearing, vol. 28, no. 2, 2007.
-
(2007)
AAS Ear and Hearing
, vol.28
, Issue.2
-
-
Koch, D.B.1
Downing, M.2
Osberger, M.J.3
Litvak, L.4
-
24
-
-
0027493144
-
Design and evaluation of a CIS processing strategy for multichannel cochlear implants
-
B. S. Wilson, C. C. Finley, D. T. Lawson, R. D. Wolford, and M. Zerbi, "Design and evaluation of a CIS processing strategy for multichannel cochlear implants," J. Rehab. Res. Develop., vol. 30, no. 1, pp. 110-116, 1993.
-
(1993)
J. Rehab. Res. Develop
, vol.30
, Issue.1
, pp. 110-116
-
-
Wilson, B.S.1
Finley, C.C.2
Lawson, D.T.3
Wolford, R.D.4
Zerbi, M.5
-
25
-
-
13444273329
-
A 126 μW cochlear chip for a totally implantable system
-
Feb
-
J. Georgiou and C. Toumazou, "A 126 μW cochlear chip for a totally implantable system," IEEE J. Solid-State Circuits, vol. 40, no. 2, pp. 430-443, Feb. 2005.
-
(2005)
IEEE J. Solid-State Circuits
, vol.40
, Issue.2
, pp. 430-443
-
-
Georgiou, J.1
Toumazou, C.2
-
26
-
-
0141885997
-
An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC
-
Oct
-
S. C. DeMarco, W. Liu, P. R. Singh, G. Lazzi, M. S. Humayun, and J. D. Weiland, "An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC," IEEE J. Solid-State Circuits, vol. 38, no. 10, pp. 1679-1790, Oct. 2003.
-
(2003)
IEEE J. Solid-State Circuits
, vol.38
, Issue.10
, pp. 1679-1790
-
-
DeMarco, S.C.1
Liu, W.2
Singh, P.R.3
Lazzi, G.4
Humayun, M.S.5
Weiland, J.D.6
-
27
-
-
0037744627
-
A CMOS micro-power wideband data/power transfer system for biomedical implants
-
O. Omeni and C. Toumazou, "A CMOS micro-power wideband data/power transfer system for biomedical implants," in Proc. IEEE Int. Symp. on Circuits Syst., 2003, vol. 5, pp. 61-65.
-
(2003)
Proc. IEEE Int. Symp. on Circuits Syst
, vol.5
, pp. 61-65
-
-
Omeni, O.1
Toumazou, C.2
-
28
-
-
14544287796
-
An implantable neural interface micro-stimulator chip with external controllability
-
C.-C. Wang, Y.-H. Hsueh, Y.-T. Hsiao, U. F. Chiot, C.-C. Huang, and P.-L. Liu, "An implantable neural interface micro-stimulator chip with external controllability," in Proc. IEEE Asia-Pacific Conf. on Adv. Syst. Integr. Circuits, 2004, pp. 356-359.
-
(2004)
Proc. IEEE Asia-Pacific Conf. on Adv. Syst. Integr. Circuits
, pp. 356-359
-
-
Wang, C.-C.1
Hsueh, Y.-H.2
Hsiao, Y.-T.3
Chiot, U.F.4
Huang, C.-C.5
Liu, P.-L.6
-
29
-
-
39549119112
-
A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6 nA DC error for 1-mA full-scale stimulation
-
Sep
-
S. J.-J. Sit and R. Sarpeshkar, "A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6 nA DC error for 1-mA full-scale stimulation," IEEE Trans. Biomed. Circuits Syst. vol. 1, no. 3, pp. 172-183, Sep. 2007.
-
(2007)
IEEE Trans. Biomed. Circuits Syst
, vol.1
, Issue.3
, pp. 172-183
-
-
Sit, S.J.-J.1
Sarpeshkar, R.2
-
30
-
-
34548850105
-
Novel charge-metering stimulus amplifier for biomimetic implantable prosthesis
-
X. Fang, J. Wills, J. Granacki, J. LaCoss, A. Arakeliana, and J. Weiland, "Novel charge-metering stimulus amplifier for biomimetic implantable prosthesis," in Proc. IEEE Int. Symp. on Circuits Syst. 2007, pp. 569-572.
-
(2007)
Proc. IEEE Int. Symp. on Circuits Syst
, pp. 569-572
-
-
Fang, X.1
Wills, J.2
Granacki, J.3
LaCoss, J.4
Arakeliana, A.5
Weiland, J.6
-
32
-
-
34548826067
-
A 0.1 mm, digitally programmable nerve stimulation pad cell with high-voltage capability for a retinal implant
-
M. Ortmanns, N. Unger, A. Rocke, M. Gehrke, and H. J. Tietdke, "A 0.1 mm, digitally programmable nerve stimulation pad cell with high-voltage capability for a retinal implant," in Proc. IEEE Int. Solid-State Circuits Conf., 2006, pp. 89-98.
-
(2006)
Proc. IEEE Int. Solid-State Circuits Conf
, pp. 89-98
-
-
Ortmanns, M.1
Unger, N.2
Rocke, A.3
Gehrke, M.4
Tietdke, H.J.5
|