메뉴 건너뛰기




Volumn , Issue , 2007, Pages 40-43

Towards an implantable vestibular prosthesis: The surgical challenges

Author keywords

Implantable; Medical imaging; Microsurgery; Prosthesis; Vestibular

Indexed keywords

BIOLOGICAL ORGANS; IMPLANTS (SURGICAL); MEDICAL IMAGING; MICROARRAYS; MICROELECTRODES; PROSTHETICS;

EID: 34548739001     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CNE.2007.369606     Document Type: Conference Paper
Times cited : (3)

References (19)
  • 1
    • 0036154137 scopus 로고    scopus 로고
    • System Design and Performance of a Unilateral Horizontal Semicircular Canal Prosthesis
    • W. Gong and D. M. Merfeld, "System Design and Performance of a Unilateral Horizontal Semicircular Canal Prosthesis," IEEE Transactions on Biomedical Engineering, vol. 49, no. 2, pp. 175-181, 2002.
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.2 , pp. 175-181
    • Gong, W.1    Merfeld, D.M.2
  • 2
    • 0038006353 scopus 로고    scopus 로고
    • Vestibular adaptation studied with a prosthetic semicircular canal
    • R. F. Lewis, W. Gong, M. Ramsey, et al., "Vestibular adaptation studied with a prosthetic semicircular canal," Journal of Vestibular Research, vol. 12, pp. 87-94, 2003.
    • (2003) Journal of Vestibular Research , vol.12 , pp. 87-94
    • Lewis, R.F.1    Gong, W.2    Ramsey, M.3
  • 3
    • 31544435478 scopus 로고    scopus 로고
    • An Electronic Prosthesis Mimicking the Dynamic Vestibular Function
    • A. M. Shkel, and F-G. Zeng, "An Electronic Prosthesis Mimicking the Dynamic Vestibular Function," Audiology and Neurotology, vol. 11, pp. 113-122, 2006.
    • (2006) Audiology and Neurotology , vol.11 , pp. 113-122
    • Shkel, A.M.1    Zeng, F.-G.2
  • 5
    • 0030611488 scopus 로고    scopus 로고
    • Computed tomography data based rapid prototyping model of the temporal bone before cochlear implant surgery
    • H. Lopponen, T. Holma, M. Sorri, et al., "Computed tomography data based rapid prototyping model of the temporal bone before cochlear implant surgery," Acta Otolaryngol Suppl., vol. 529, pp. 47-49, 1997.
    • (1997) Acta Otolaryngol Suppl , vol.529 , pp. 47-49
    • Lopponen, H.1    Holma, T.2    Sorri, M.3
  • 6
    • 0032797453 scopus 로고    scopus 로고
    • Comparison of 3D Visualization techniques for depicting the scala vestibuli and scala tympani of the cochlea, by using high-resolution MR imaging
    • P. Hans, A. J. Grant, R. D. Laitt, et al., "Comparison of 3D Visualization techniques for depicting the scala vestibuli and scala tympani of the cochlea, by using high-resolution MR imaging," Am. Journ. Neuroradiology, vol. 20, no. 7, pp. 1197-1206, 1999.
    • (1999) Am. Journ. Neuroradiology , vol.20 , Issue.7 , pp. 1197-1206
    • Hans, P.1    Grant, A.J.2    Laitt, R.D.3
  • 8
    • 0029813674 scopus 로고    scopus 로고
    • Visualization of Inner Ear Structures by Three-Dimensional High-Resolution Magnetic Resonance Imaging
    • B. Arnold, L. Jager and G. Grevers, "Visualization of Inner Ear Structures by Three-Dimensional High-Resolution Magnetic Resonance Imaging," American Journal of Otology, vol. 17, pp. 480-485, 1996.
    • (1996) American Journal of Otology , vol.17 , pp. 480-485
    • Arnold, B.1    Jager, L.2    Grevers, G.3
  • 9
    • 34548789288 scopus 로고    scopus 로고
    • Head and Neck Imaging, ch
    • Mosby, 3rd ed
    • D. W. Chakeres, M. Oehler, et al., Head and Neck Imaging, ch. Temporal bone imaging, pp. 1319-1350. Mosby, 3rd ed., 1996.
    • (1996) Temporal bone imaging , pp. 1319-1350
    • Chakeres, D.W.1    Oehler, M.2
  • 13
    • 33646117751 scopus 로고    scopus 로고
    • CT-MR image fusion for the management of skull base lesions
    • J. L. Leong, P. S. Batra and M. J. Citardi, "CT-MR image fusion for the management of skull base lesions," Otolaryngology - Head and Neck Surgery, vol. 134, no. 5, pp. 868-876, 2006.
    • (2006) Otolaryngology - Head and Neck Surgery , vol.134 , Issue.5 , pp. 868-876
    • Leong, J.L.1    Batra, P.S.2    Citardi, M.J.3
  • 15
    • 0036068318 scopus 로고    scopus 로고
    • The application accuracy of the NeuroMate robot-A quantitative comparison with frameless and frame-based surgical localization systems
    • Q. H. Li, L. Zamorano L. A. Pandya, et al., "The application accuracy of the NeuroMate robot-A quantitative comparison with frameless and frame-based surgical localization systems," Computer Aided Surgery, vol. 7, no. 2, pp. 90-98, 2002.
    • (2002) Computer Aided Surgery , vol.7 , Issue.2 , pp. 90-98
    • Li, Q.H.1    Zamorano, L.2    Pandya, L.A.3
  • 16
    • 0031195394 scopus 로고    scopus 로고
    • Registration of Head Volume Images Using Implantable Fiducial Markers
    • R. M. Calvin, J. M. Fitzpatrick, M. Y. Yang, et al., "Registration of Head Volume Images Using Implantable Fiducial Markers," IEEE Trans. Medical Imaging, vol. 16, no. 4. pp. 447-462, 1997.
    • (1997) IEEE Trans. Medical Imaging , vol.16 , Issue.4 , pp. 447-462
    • Calvin, R.M.1    Fitzpatrick, J.M.2    Yang, M.Y.3
  • 17
    • 0142196069 scopus 로고    scopus 로고
    • Bone-mounted miniature robot for surgical procedures: Concept and clinical applications
    • M. Shoham, M. Burman, E. Zehavi, et al., "Bone-mounted miniature robot for surgical procedures: Concept and clinical applications," IEEE Trans. Robotics and Automation, vol. 19, no. 5, pp. 893-901, 2003.
    • (2003) IEEE Trans. Robotics and Automation , vol.19 , Issue.5 , pp. 893-901
    • Shoham, M.1    Burman, M.2    Zehavi, E.3
  • 18
    • 34548776128 scopus 로고
    • Us patent 3,638,933: Precision x-y positioning: table
    • H. L. H. R. W. Burnette and R. V. Lukes, "Us patent 3,638,933: Precision x-y positioning: table," 1970.
    • (1970)
    • Burnette, H.L.H.R.W.1    Lukes, R.V.2
  • 19
    • 34548799983 scopus 로고
    • Us patent 3,975,968: Precision lead screw assembly and nut
    • F. R. Chaffin, "Us patent 3,975,968: Precision lead screw assembly and nut," 1976.
    • (1976)
    • Chaffin, F.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.