메뉴 건너뛰기




Volumn 53, Issue 6, 2007, Pages 734-741

Mechanical cavopulmonary assist for the univentricular Fontan circulation using a novel folding propeller blood pump

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; DISEASES; MACHINE DESIGN; PHYSIOLOGY;

EID: 36549087344     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e318159d14b     Document Type: Article
Times cited : (28)

References (34)
  • 1
    • 27744513900 scopus 로고    scopus 로고
    • Ventricular dysfunction of the functionally univentricular heart: Management and outcomes
    • Gewillig M: Ventricular dysfunction of the functionally univentricular heart: Management and outcomes. Cardiol Young 15: 31-34, 2005.
    • (2005) Cardiol Young , vol.15 , pp. 31-34
    • Gewillig, M.1
  • 2
    • 0344665459 scopus 로고    scopus 로고
    • Cavopulmonary assist: Circulatory support for the univentricular Fontan circulation
    • Rodefeld M, Boyd JH, LaLone BJ, et al: Cavopulmonary assist: Circulatory support for the univentricular Fontan circulation. Ann Thorac Surg 76: 1911-1916, 2003.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1911-1916
    • Rodefeld, M.1    Boyd, J.H.2    LaLone, B.J.3
  • 3
    • 1542374007 scopus 로고    scopus 로고
    • Cavopulmonary assist in the neonate: An alternative strategy for single-ventricle palliation
    • Rodefeld M, Boyd JH, Myers CD, et al: Cavopulmonary assist in the neonate: An alternative strategy for single-ventricle palliation. J Thorac Cardiovasc Surg 127: 705-711, 2004.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 705-711
    • Rodefeld, M.1    Boyd, J.H.2    Myers, C.D.3
  • 5
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pumps
    • Burgeen G, Antaki JF, Wu ZJ, Holmes AJ: Computational fluid dynamics as a development tool for rotary blood pumps. Artif Organs 25: 336-340, 2001.
    • (2001) Artif Organs , vol.25 , pp. 336-340
    • Burgeen, G.1    Antaki, J.F.2    Wu, Z.J.3    Holmes, A.J.4
  • 6
    • 0032866184 scopus 로고    scopus 로고
    • Development of design methods for a centrifugal blood pump with a fluid dynamic approach: Results in hemolysis tests
    • Masuzawa T, Tsukiya T, Endo S, et al: Development of design methods for a centrifugal blood pump with a fluid dynamic approach: Results in hemolysis tests. Artif Organs 23: 757-761, 1999.
    • (1999) Artif Organs , vol.23 , pp. 757-761
    • Masuzawa, T.1    Tsukiya, T.2    Endo, S.3
  • 7
    • 0032874351 scopus 로고    scopus 로고
    • Computational fluid dynamics to establish the design process of a centrifugal blood pump: Second report
    • Miyazoe Y, Sawairi T, Ito K, et al: Computational fluid dynamics to establish the design process of a centrifugal blood pump: Second report. Artif Organs 23: 762-768, 1999.
    • (1999) Artif Organs , vol.23 , pp. 762-768
    • Miyazoe, Y.1    Sawairi, T.2    Ito, K.3
  • 8
    • 0033917489 scopus 로고    scopus 로고
    • Computational fluid dynamics analysis of hydrodynamic bearings of the VentrAssist rotary blood pump
    • Qian Y, Bertram C: Computational fluid dynamics analysis of hydrodynamic bearings of the VentrAssist rotary blood pump. Artif Organs 24: 488-491, 1999.
    • (1999) Artif Organs , vol.24 , pp. 488-491
    • Qian, Y.1    Bertram, C.2
  • 10
    • 0242333304 scopus 로고    scopus 로고
    • CFD prediction of blood damage in a centrifugal pump
    • Song X, Throckmorton AL, Wood HG, et al: CFD prediction of blood damage in a centrifugal pump. Artif Organs 27: 938-941, 2003.
    • (2003) Artif Organs , vol.27 , pp. 938-941
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3
  • 12
    • 1242342222 scopus 로고    scopus 로고
    • Design of a continuous flow centrifugal pediatric ventricular assist device
    • Throckmorton A, Wood HG, Day SW, et al: Design of a continuous flow centrifugal pediatric ventricular assist device. Int J Artif Organs 26: 1015-1031, 2003.
    • (2003) Int J Artif Organs , vol.26 , pp. 1015-1031
    • Throckmorton, A.1    Wood, H.G.2    Day, S.W.3
  • 13
    • 15444362825 scopus 로고    scopus 로고
    • Computational analysis of an axial flow pediatric ventricular assist device
    • Throckmorton A, Untaroiu A, Allaire PE, et al: Computational analysis of an axial flow pediatric ventricular assist device. Artif Organs 28: 881-891, 2004.
    • (2004) Artif Organs , vol.28 , pp. 881-891
    • Throckmorton, A.1    Untaroiu, A.2    Allaire, P.E.3
  • 14
    • 26444524441 scopus 로고    scopus 로고
    • Computational design and experimental performance testing of an axial flow pediatric VAD
    • Throckmorton A, Lim DS, McCulloch MA, et al: Computational design and experimental performance testing of an axial flow pediatric VAD. ASAIO J 51: 629-635, 2005.
    • (2005) ASAIO J , vol.51 , pp. 629-635
    • Throckmorton, A.1    Lim, D.S.2    McCulloch, M.A.3
  • 15
    • 27744605262 scopus 로고    scopus 로고
    • Numerical and experimental analysis of an axial flow LVAD: Influence of the diffuser on the overall pump performance
    • Untaroiu A, Throckmorton AL, Wood HG, et al: Numerical and experimental analysis of an axial flow LVAD: Influence of the diffuser on the overall pump performance. Artif Organs 29: 581-591, 2005.
    • (2005) Artif Organs , vol.29 , pp. 581-591
    • Untaroiu, A.1    Throckmorton, A.L.2    Wood, H.G.3
  • 17
    • 0034837086 scopus 로고    scopus 로고
    • Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
    • Apel J, Paul R, Klaus S, et al: Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. Artif Organs 25: 341-347, 2001.
    • (2001) Artif Organs , vol.25 , pp. 341-347
    • Apel, J.1    Paul, R.2    Klaus, S.3
  • 18
    • 0029085081 scopus 로고
    • Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump
    • Bludszuweit C: Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. Artif Organs 19: 590-596, 1995.
    • (1995) Artif Organs , vol.19 , pp. 590-596
    • Bludszuweit, C.1
  • 19
    • 0029090222 scopus 로고
    • Model for general mechanical blood damage prediction
    • Bludszuweit C: Model for general mechanical blood damage prediction. Artif Organs 19: 583-589, 1995.
    • (1995) Artif Organs , vol.19 , pp. 583-589
    • Bludszuweit, C.1
  • 20
    • 0025082325 scopus 로고
    • Estimation of shear stress related blood damage in heart valve prostheses: In vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger LJ, Optiz R, Reul H: Estimation of shear stress related blood damage in heart valve prostheses: In vitro comparison of 25 aortic valves. Int J Artif Organs 13: 300-306, 1990.
    • (1990) Int J Artif Organs , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Optiz, R.3    Reul, H.4
  • 21
    • 33644876647 scopus 로고    scopus 로고
    • Computational design and experimental testing of a novel axial flow LVAD
    • Untaroiu A, Throckmorton AL, Day SW, et al: Computational design and experimental testing of a novel axial flow LVAD. ASAIO J 51: 702-710, 2005.
    • (2005) ASAIO J , vol.51 , pp. 702-710
    • Untaroiu, A.1    Throckmorton, A.L.2    Day, S.W.3
  • 23
    • 0038518234 scopus 로고    scopus 로고
    • Shear stress related blood damage in laminar couette flow
    • Paul R, Apel J, Klaus S, et al: Shear stress related blood damage in laminar couette flow. Artif Organs 27: 517-529, 2003.
    • (2003) Artif Organs , vol.27 , pp. 517-529
    • Paul, R.1    Apel, J.2    Klaus, S.3
  • 24
    • 9144255069 scopus 로고    scopus 로고
    • Routine mechanical ventricular assist following the Norwood procedure - Improved neurologic outcome and excellent hospital survival
    • Ungerleider R, Shen I, Yeh T, et al: Routine mechanical ventricular assist following the Norwood procedure - Improved neurologic outcome and excellent hospital survival. Ann Thorac Surg 77: 18-22, 2004.
    • (2004) Ann Thorac Surg , vol.77 , pp. 18-22
    • Ungerleider, R.1    Shen, I.2    Yeh, T.3
  • 25
    • 36549080453 scopus 로고    scopus 로고
    • Newborn cavopulmonary assist: Benefit of pulsatile pulmonary perfusion
    • Presented at:, American College of Surgeons
    • Boyd J, Myers CD, Presson RG, et al: Newborn cavopulmonary assist: benefit of pulsatile pulmonary perfusion. Presented at: 90th Annual Clinical Congress, American College of Surgeons, 2004.
    • (2004) 90th Annual Clinical Congress
    • Boyd, J.1    Myers, C.D.2    Presson, R.G.3
  • 26
    • 29144497913 scopus 로고    scopus 로고
    • Neonatal cavopulmonary assist: An alternative strategy for single-ventricle palliation
    • Myers C, Boyd JH, Presson RG, et al: Neonatal cavopulmonary assist: An alternative strategy for single-ventricle palliation. J Thorac Cardiovasc Surg 81: 257-263, 2006.
    • (2006) J Thorac Cardiovasc Surg , vol.81 , pp. 257-263
    • Myers, C.1    Boyd, J.H.2    Presson, R.G.3
  • 27
    • 29144506917 scopus 로고    scopus 로고
    • Twenty-four hour cadiopulmonary stability in a model of assisted newborn Fontan circulation
    • Myers C, Mattix K, Presson RG, et al: Twenty-four hour cadiopulmonary stability in a model of assisted newborn Fontan circulation. Ann Thorac Surg 81: 264-271, 2006.
    • (2006) Ann Thorac Surg , vol.81 , pp. 264-271
    • Myers, C.1    Mattix, K.2    Presson, R.G.3
  • 28
    • 36549076565 scopus 로고    scopus 로고
    • Design, Development and Hemodynamic Analysis of a Low-Pressure Cavopulmonary Assist Device Within the Total Cavopulmonary Connection
    • Idaho, Western Thoracic Surgical Association
    • Wang R, Hertzberg J, Lacour-Gayet F, Shandas R: Design, Development and Hemodynamic Analysis of a Low-Pressure Cavopulmonary Assist Device Within the Total Cavopulmonary Connection. Sun Valley Resort, Idaho, Western Thoracic Surgical Association, 2006.
    • (2006) Sun Valley Resort
    • Wang, R.1    Hertzberg, J.2    Lacour-Gayet, F.3    Shandas, R.4
  • 29
    • 33751212454 scopus 로고    scopus 로고
    • Initial experience with the development and numerical and in vitro studies of a novel low-pressure artificial right ventricle for pediatric Fontan patients
    • Wang R, Lacour-Gayet FG, Lanning CJ, et al: Initial experience with the development and numerical and in vitro studies of a novel low-pressure artificial right ventricle for pediatric Fontan patients. ASAIO J 52: 682-692, 2006.
    • (2006) ASAIO J , vol.52 , pp. 682-692
    • Wang, R.1    Lacour-Gayet, F.G.2    Lanning, C.J.3
  • 30
    • 17444368111 scopus 로고    scopus 로고
    • Physics-driven CFD modeling of complex anatomical cardiovascular flows - A TCPC case study
    • Pekkan K, Zelicourt DD, Ge L, et al: Physics-driven CFD modeling of complex anatomical cardiovascular flows - A TCPC case study. Ann Biomed Eng 33: 284-300, 2005.
    • (2005) Ann Biomed Eng , vol.33 , pp. 284-300
    • Pekkan, K.1    Zelicourt, D.D.2    Ge, L.3
  • 31
    • 0033490526 scopus 로고    scopus 로고
    • Initial tests with a new cardiac assist device
    • Reitan O, Ohlin H, Peterzen B, et al: Initial tests with a new cardiac assist device. ASAIO J 45: 317-321, 1999.
    • (1999) ASAIO J , vol.45 , pp. 317-321
    • Reitan, O.1    Ohlin, H.2    Peterzen, B.3
  • 32
    • 0034098790 scopus 로고    scopus 로고
    • Hydrodynamic properties of a new percutaneous intra-aortic axial flow pump
    • Reitan O, Sternby J, Ohlin H: Hydrodynamic properties of a new percutaneous intra-aortic axial flow pump. ASAIO J 46: 323-329, 2000.
    • (2000) ASAIO J , vol.46 , pp. 323-329
    • Reitan, O.1    Sternby, J.2    Ohlin, H.3
  • 33
    • 0036266083 scopus 로고    scopus 로고
    • Left ventricular heart failure model for testing cardiac assist devices
    • Reitan O, Steen S, Ohlin H: Left ventricular heart failure model for testing cardiac assist devices. ASAIO J 48: 71-75, 2002.
    • (2002) ASAIO J , vol.48 , pp. 71-75
    • Reitan, O.1    Steen, S.2    Ohlin, H.3
  • 34
    • 0242426513 scopus 로고    scopus 로고
    • Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model
    • Reitan O, Steen S, Ohlin H: Hemodynamic effects of a new percutaneous circulatory support device in a left ventricular failure model. ASAIO J 49: 731-736, 2003.
    • (2003) ASAIO J , vol.49 , pp. 731-736
    • Reitan, O.1    Steen, S.2    Ohlin, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.