메뉴 건너뛰기




Volumn 52, Issue 4, 2008, Pages 777-808

Computer-aided Design/Computer-aided Manufacturing Applications Using CT and Cone Beam CT Scanning Technology

Author keywords

[No Author keywords available]

Indexed keywords

CASE REPORT; COMPUTER AIDED DESIGN; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER INTERFACE; COMPUTER PROGRAM; CONE BEAM COMPUTED TOMOGRAPHY; DENTURE; HUMAN; IMAGE PROCESSING; INSTRUMENTATION; MALE; MANDIBLE; MANDIBULAR NERVE; METHODOLOGY; MIDDLE AGED; OSTEOLYSIS; OSTEOTOMY; PATIENT CARE PLANNING; PERIODONTAL DISEASE; RADIOGRAPHY; RADIOLOGY; REVIEW; THREE DIMENSIONAL IMAGING; TOOTH EXTRACTION; TOOTH IMPLANTATION;

EID: 52249087776     PISSN: 00118532     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cden.2008.07.001     Document Type: Review
Times cited : (40)

References (43)
  • 1
    • 3042684104 scopus 로고    scopus 로고
    • CT scan technology: an evolving tool for predictable implant placement and restoration
    • Ganz S.D. CT scan technology: an evolving tool for predictable implant placement and restoration. Int Mag Oral Implantol 1 (2001) 6-13
    • (2001) Int Mag Oral Implantol , vol.1 , pp. 6-13
    • Ganz, S.D.1
  • 2
    • 23944440357 scopus 로고    scopus 로고
    • Presurgical planning with CT-derived fabrication of surgical guides
    • Ganz S.D. Presurgical planning with CT-derived fabrication of surgical guides. J Oral Maxillofac Surg 63 9 Suppl 2 (2005) 59-71
    • (2005) J Oral Maxillofac Surg , vol.63 , Issue.9 SUPPL. 2 , pp. 59-71
    • Ganz, S.D.1
  • 3
    • 52249087002 scopus 로고    scopus 로고
    • Defining new paradigms for assessment of implant receptor sites-the use of CT/CBCT and interactive virtual treatment planning for congenitally missing lateral incisors
    • Ganz S.D. Defining new paradigms for assessment of implant receptor sites-the use of CT/CBCT and interactive virtual treatment planning for congenitally missing lateral incisors. Compend Contin Educ Dent 29 5 (2008) 256-267
    • (2008) Compend Contin Educ Dent , vol.29 , Issue.5 , pp. 256-267
    • Ganz, S.D.1
  • 4
    • 33745394071 scopus 로고    scopus 로고
    • Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the Internet for immediate loading of dental implants
    • Balshi S.F., Wolfinger G.J., and Balshi T.J. Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the Internet for immediate loading of dental implants. Int J Periodontics Restorative Dent 26 3 (2006) 239-247
    • (2006) Int J Periodontics Restorative Dent , vol.26 , Issue.3 , pp. 239-247
    • Balshi, S.F.1    Wolfinger, G.J.2    Balshi, T.J.3
  • 5
    • 1442278453 scopus 로고    scopus 로고
    • Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants
    • Ganz S.D. Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants. Pract Proced Aesthet Dent 15 10 (2003) 763-771
    • (2003) Pract Proced Aesthet Dent , vol.15 , Issue.10 , pp. 763-771
    • Ganz, S.D.1
  • 6
    • 1342285090 scopus 로고    scopus 로고
    • The use of a custom template for immediate loading with the definitive prosthesis: a clinical report
    • Marchack C.B., and Moy P.K. The use of a custom template for immediate loading with the definitive prosthesis: a clinical report. J Calif Dent Assoc 31 12 (2003) 925-929
    • (2003) J Calif Dent Assoc , vol.31 , Issue.12 , pp. 925-929
    • Marchack, C.B.1    Moy, P.K.2
  • 7
    • 0141608169 scopus 로고    scopus 로고
    • Computer-assisted implant placement. A case report: treatment of the mandible
    • Tardieu P.B., Vrielinck L., and Escolano E. Computer-assisted implant placement. A case report: treatment of the mandible. Int J Oral Maxillofac Implants 18 4 (2003) 599-604
    • (2003) Int J Oral Maxillofac Implants , vol.18 , Issue.4 , pp. 599-604
    • Tardieu, P.B.1    Vrielinck, L.2    Escolano, E.3
  • 8
    • 11144240533 scopus 로고    scopus 로고
    • An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report
    • Marchack C.B. An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report. J Prosthet Dent 93 1 (2005) 8-12
    • (2005) J Prosthet Dent , vol.93 , Issue.1 , pp. 8-12
    • Marchack, C.B.1
  • 9
    • 34548602131 scopus 로고    scopus 로고
    • A simple technique for immediate placement of definitive engaging custom abutments using computerized tomography and flapless guided surgery
    • Sherry J.S., Sims L.O., and Balshi S.F. A simple technique for immediate placement of definitive engaging custom abutments using computerized tomography and flapless guided surgery. Quintessence Int 38 9 (2007) 755-762
    • (2007) Quintessence Int , vol.38 , Issue.9 , pp. 755-762
    • Sherry, J.S.1    Sims, L.O.2    Balshi, S.F.3
  • 10
    • 34347364569 scopus 로고    scopus 로고
    • CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient
    • Marchack C.B. CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient. J Prosthet Dent 97 6 (2007) 389-394
    • (2007) J Prosthet Dent , vol.97 , Issue.6 , pp. 389-394
    • Marchack, C.B.1
  • 11
    • 52249097715 scopus 로고    scopus 로고
    • Ganz SD. "Using stereolithographic CT technology for immediate functional and non-functional loading". Presented at the Annual Meeting of the Academy of Osseointegration. Orlando, Florida, March 12, 2005.
    • Ganz SD. "Using stereolithographic CT technology for immediate functional and non-functional loading". Presented at the Annual Meeting of the Academy of Osseointegration. Orlando, Florida, March 12, 2005.
  • 12
    • 33644645128 scopus 로고    scopus 로고
    • Techniques for the use of CT imaging for the fabrication of surgical guides
    • Ganz S.D. Techniques for the use of CT imaging for the fabrication of surgical guides. Atlas Oral Maxillofac Surg Clin North Am 14 1 (2006) 75-97
    • (2006) Atlas Oral Maxillofac Surg Clin North Am , vol.14 , Issue.1 , pp. 75-97
    • Ganz, S.D.1
  • 13
    • 13144279301 scopus 로고    scopus 로고
    • Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study
    • Ortorp A., and Jemt T. Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study. Clin Implant Dent Relat Res 6 4 (2004) 199-209
    • (2004) Clin Implant Dent Relat Res , vol.6 , Issue.4 , pp. 199-209
    • Ortorp, A.1    Jemt, T.2
  • 14
    • 31344468073 scopus 로고    scopus 로고
    • A 3-year retrospective study of Cresco frameworks: preload and complications
    • Hjalmarsson L., and Smedberg J.I. A 3-year retrospective study of Cresco frameworks: preload and complications. Clin Implant Dent Relat Res 7 4 (2005) 189-199
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.4 , pp. 189-199
    • Hjalmarsson, L.1    Smedberg, J.I.2
  • 15
    • 18744392533 scopus 로고    scopus 로고
    • Fabrication of an implant-supported reconstruction utilizing CAD/CAM technology
    • [quiz 80]
    • Mitrani R., Vasilic M., and Bruguera A. Fabrication of an implant-supported reconstruction utilizing CAD/CAM technology. Pract Proced Aesthet Dent 17 1 (2005) 71-78 [quiz 80]
    • (2005) Pract Proced Aesthet Dent , vol.17 , Issue.1 , pp. 71-78
    • Mitrani, R.1    Vasilic, M.2    Bruguera, A.3
  • 16
    • 37649007267 scopus 로고    scopus 로고
    • Complete-arch maxillary rehabilitation using a custom-designed and manufactured titanium framework: a clinical report
    • Ehrenkranz H., Langer B., and Marotta L. Complete-arch maxillary rehabilitation using a custom-designed and manufactured titanium framework: a clinical report. J Prosthet Dent 99 1 (2008) 8-13
    • (2008) J Prosthet Dent , vol.99 , Issue.1 , pp. 8-13
    • Ehrenkranz, H.1    Langer, B.2    Marotta, L.3
  • 17
    • 0141516406 scopus 로고    scopus 로고
    • Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study
    • Jemt T., Henry P., Lindén B., et al. Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study. Int J Prosthodont 16 4 (2003) 415-421
    • (2003) Int J Prosthodont , vol.16 , Issue.4 , pp. 415-421
    • Jemt, T.1    Henry, P.2    Lindén, B.3
  • 18
    • 0036729141 scopus 로고    scopus 로고
    • The milled implant bar: an alternative to spark erosion
    • Brudvik J.S., and Chigurupati K. The milled implant bar: an alternative to spark erosion. J Can Dent Assoc 68 8 (2002) 485-488
    • (2002) J Can Dent Assoc , vol.68 , Issue.8 , pp. 485-488
    • Brudvik, J.S.1    Chigurupati, K.2
  • 19
    • 33745763436 scopus 로고    scopus 로고
    • Two new clinical/laboratory protocols for CAD/CAM implant restorations
    • Drago C.J. Two new clinical/laboratory protocols for CAD/CAM implant restorations. J Am Dent Assoc 137 6 (2006) 794-800
    • (2006) J Am Dent Assoc , vol.137 , Issue.6 , pp. 794-800
    • Drago, C.J.1
  • 20
    • 34250313679 scopus 로고    scopus 로고
    • Treatment of an edentulous patient with CAD/CAM technology: a clinical report
    • Drago C.J., and Peterson T. Treatment of an edentulous patient with CAD/CAM technology: a clinical report. J Prosthodont 16 3 (2007) 200-208
    • (2007) J Prosthodont , vol.16 , Issue.3 , pp. 200-208
    • Drago, C.J.1    Peterson, T.2
  • 21
    • 34347361565 scopus 로고    scopus 로고
    • Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients
    • Sanna A.M., Molly L., and van Steenberghe D. Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. J Prosthet Dent 97 6 (2007) 331-339
    • (2007) J Prosthet Dent , vol.97 , Issue.6 , pp. 331-339
    • Sanna, A.M.1    Molly, L.2    van Steenberghe, D.3
  • 22
    • 0029418322 scopus 로고
    • The triangle of bone-a formula for successful implant placement and restoration
    • Ganz S.D. The triangle of bone-a formula for successful implant placement and restoration. The Implant Society, Inc 5 5 (1995) 2-6
    • (1995) The Implant Society, Inc , vol.5 , Issue.5 , pp. 2-6
    • Ganz, S.D.1
  • 23
    • 34548854831 scopus 로고    scopus 로고
    • The reality of anatomy and the triangle of bone
    • Ganz S.D. The reality of anatomy and the triangle of bone. Inside Dentistry. 2 5 (2006) 72-77
    • (2006) Inside Dentistry. , vol.2 , Issue.5 , pp. 72-77
    • Ganz, S.D.1
  • 24
    • 34548051408 scopus 로고    scopus 로고
    • CT-derived model-based surgery for immediate loading of maxillary anterior implants
    • [quiz 320, 302]
    • Ganz S.D. CT-derived model-based surgery for immediate loading of maxillary anterior implants. Pract Proced Aesthet Dent 19 5 (2007) 311-318 [quiz 320, 302]
    • (2007) Pract Proced Aesthet Dent , vol.19 , Issue.5 , pp. 311-318
    • Ganz, S.D.1
  • 25
    • 0038495759 scopus 로고    scopus 로고
    • Use of the Atlantis abutment in restorative practice speeds time to function and aesthetics
    • [Interview]
    • Osorio J. Use of the Atlantis abutment in restorative practice speeds time to function and aesthetics. [Interview]. Dent Implantol Update 11 8 (2000) 57-62
    • (2000) Dent Implantol Update , vol.11 , Issue.8 , pp. 57-62
    • Osorio, J.1
  • 26
    • 0034308991 scopus 로고    scopus 로고
    • Ideal gingival form with computer-generated permanent healing abutments
    • 800-801
    • Kerstein R.B., Castellucci F., and Osorio J. Ideal gingival form with computer-generated permanent healing abutments. Compend Contin Educ Dent 21 10 (2000) 793-797 800-801
    • (2000) Compend Contin Educ Dent , vol.21 , Issue.10 , pp. 793-797
    • Kerstein, R.B.1    Castellucci, F.2    Osorio, J.3
  • 27
    • 0034263589 scopus 로고    scopus 로고
    • The Procera abutment-the fifth generation abutment for dental implants
    • Kucey B.K., and Fraser D.C. The Procera abutment-the fifth generation abutment for dental implants. J Can Dent Assoc 66 8 (2000) 445-449
    • (2000) J Can Dent Assoc , vol.66 , Issue.8 , pp. 445-449
    • Kucey, B.K.1    Fraser, D.C.2
  • 28
    • 0035295530 scopus 로고    scopus 로고
    • Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations
    • Luthardt R.G., Sandkuhl O., Herold V., et al. Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. Int J Prosthodont 14 2 (2001) 146-151
    • (2001) Int J Prosthodont , vol.14 , Issue.2 , pp. 146-151
    • Luthardt, R.G.1    Sandkuhl, O.2    Herold, V.3
  • 29
    • 0035411856 scopus 로고    scopus 로고
    • Computerized milled solid implant abutments utilized at second stage surgery
    • Schneider A., and Kurtzman G.M. Computerized milled solid implant abutments utilized at second stage surgery. Gen Dent 49 4 (2001) 416-420
    • (2001) Gen Dent , vol.49 , Issue.4 , pp. 416-420
    • Schneider, A.1    Kurtzman, G.M.2
  • 30
    • 0036716163 scopus 로고    scopus 로고
    • The Atlantis components abutment: simplifying the tooth implant procedure
    • Garg A.K. The Atlantis components abutment: simplifying the tooth implant procedure. Dent Implantol Update 13 9 (2002) 65-70
    • (2002) Dent Implantol Update , vol.13 , Issue.9 , pp. 65-70
    • Garg, A.K.1
  • 31
    • 0142120282 scopus 로고    scopus 로고
    • Evaluation of the precision of fit between the Procera custom abutment and various implant systems
    • Lang L.A., Sierraalta M., Hoffensperger M., et al. Evaluation of the precision of fit between the Procera custom abutment and various implant systems. Int J Oral Maxillofac Implants 18 5 (2003) 652-658
    • (2003) Int J Oral Maxillofac Implants , vol.18 , Issue.5 , pp. 652-658
    • Lang, L.A.1    Sierraalta, M.2    Hoffensperger, M.3
  • 32
    • 33645449004 scopus 로고    scopus 로고
    • Computer-milled patient-specific abutments: incredible quality with unprecedented simplicity
    • Ganz S.D. Computer-milled patient-specific abutments: incredible quality with unprecedented simplicity. Pract Proced Aesthet Dent 15 8 Suppl (2003) 37-44
    • (2003) Pract Proced Aesthet Dent , vol.15 , Issue.8 SUPPL , pp. 37-44
    • Ganz, S.D.1
  • 33
    • 33644901797 scopus 로고    scopus 로고
    • Immediate placement and immediate provisional abutment modeling in anterior single-tooth implant restorations using a CAD/CAM application: a clinical report
    • Tselios N., Parel S.M., and Jones J.D. Immediate placement and immediate provisional abutment modeling in anterior single-tooth implant restorations using a CAD/CAM application: a clinical report. J Prosthet Dent 95 3 (2006) 181-185
    • (2006) J Prosthet Dent , vol.95 , Issue.3 , pp. 181-185
    • Tselios, N.1    Parel, S.M.2    Jones, J.D.3
  • 34
    • 36048966648 scopus 로고    scopus 로고
    • Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations
    • Quaas S., Rudolph H., and Luthardt R.G. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 35 12 (2007) 903-908
    • (2007) J Dent , vol.35 , Issue.12 , pp. 903-908
    • Quaas, S.1    Rudolph, H.2    Luthardt, R.G.3
  • 35
    • 52249092953 scopus 로고    scopus 로고
    • Computer-generated abutments using a coded healing abutment: a two-year preliminary report
    • Vafiadis D.C. Computer-generated abutments using a coded healing abutment: a two-year preliminary report. Pract Proced Aesthet Dent 19 7 (2007) 443-448
    • (2007) Pract Proced Aesthet Dent , vol.19 , Issue.7 , pp. 443-448
    • Vafiadis, D.C.1
  • 36
    • 42149108504 scopus 로고    scopus 로고
    • Immediately loaded full-arch provisional implant restorations using CAD/CAM and guided placement: maxillary and mandibular case reports
    • Allum S.R. Immediately loaded full-arch provisional implant restorations using CAD/CAM and guided placement: maxillary and mandibular case reports. Br Dent J 204 7 (2008) 377-381
    • (2008) Br Dent J , vol.204 , Issue.7 , pp. 377-381
    • Allum, S.R.1
  • 37
    • 21244506130 scopus 로고    scopus 로고
    • A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System
    • Piwowarczyk A., Ottl P., Lauer H.C., et al. A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System. J Prosthodont 14 1 (2005) 39-45
    • (2005) J Prosthodont , vol.14 , Issue.1 , pp. 39-45
    • Piwowarczyk, A.1    Ottl, P.2    Lauer, H.C.3
  • 38
    • 23944480831 scopus 로고    scopus 로고
    • Virtual-designed and computer-milled implant abutments
    • Priest G. Virtual-designed and computer-milled implant abutments. J Oral Maxillofac Surg 63 9 Suppl 2 (2005) 22-32
    • (2005) J Oral Maxillofac Surg , vol.63 , Issue.9 SUPPL. 2 , pp. 22-32
    • Priest, G.1
  • 39
    • 33748509101 scopus 로고    scopus 로고
    • An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection
    • Vigolo P., Fonzi F., Majzoub Z., et al. An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection. Int J Oral Maxillofac Implants 21 4 (2006) 575-580
    • (2006) Int J Oral Maxillofac Implants , vol.21 , Issue.4 , pp. 575-580
    • Vigolo, P.1    Fonzi, F.2    Majzoub, Z.3
  • 40
    • 33644881396 scopus 로고    scopus 로고
    • A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration
    • Grossmann Y., Pasciuta M., and Finger I.M. A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration. J Prosthet Dent 95 3 (2006) 258-261
    • (2006) J Prosthet Dent , vol.95 , Issue.3 , pp. 258-261
    • Grossmann, Y.1    Pasciuta, M.2    Finger, I.M.3
  • 41
    • 35648989009 scopus 로고    scopus 로고
    • A simplified method to assess precision of fit between framework and supporting implants: a preliminary study
    • Calderini A., Maiorana C., Garlini G., et al. A simplified method to assess precision of fit between framework and supporting implants: a preliminary study. Int J Oral Maxillofac Implants 22 5 (2007) 831-838
    • (2007) Int J Oral Maxillofac Implants , vol.22 , Issue.5 , pp. 831-838
    • Calderini, A.1    Maiorana, C.2    Garlini, G.3
  • 42
    • 33748508410 scopus 로고    scopus 로고
    • Marginal integrity of direct and indirect castings for implant abutments
    • Ganz S.D., Desai N., and Weiner S. Marginal integrity of direct and indirect castings for implant abutments. Int J Oral Maxillofac Implants 21 4 (2006) 593-599
    • (2006) Int J Oral Maxillofac Implants , vol.21 , Issue.4 , pp. 593-599
    • Ganz, S.D.1    Desai, N.2    Weiner, S.3
  • 43
    • 33746383047 scopus 로고    scopus 로고
    • Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques
    • Witkowski S., Komine F., and Gerds T. Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent 96 1 (2006) 47-52
    • (2006) J Prosthet Dent , vol.96 , Issue.1 , pp. 47-52
    • Witkowski, S.1    Komine, F.2    Gerds, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.