메뉴 건너뛰기




Volumn 43, Issue 8, 2008, Pages 1372-1376

Application of commercial glass in gamma radiation processing

Author keywords

Commercial glass; Dosimetry; Environment effects; Gamma rays

Indexed keywords

ATMOSPHERIC HUMIDITY; DATA STORAGE EQUIPMENT; DOSIMETRY; ELECTRON BEAM PUMPING; GAMMA RAYS; IRRADIATION; SILICONES; UNCERTAINTY ANALYSIS;

EID: 52049093445     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2008.05.010     Document Type: Article
Times cited : (18)

References (14)
  • 2
    • 0036387701 scopus 로고    scopus 로고
    • Commercial glass for high doses using using different dosimetric techniques
    • Caldas L.V.E., and Teixeira M.I. Commercial glass for high doses using using different dosimetric techniques. Radiat. Prot. Dosim. 101 (2002) 149-152
    • (2002) Radiat. Prot. Dosim. , vol.101 , pp. 149-152
    • Caldas, L.V.E.1    Teixeira, M.I.2
  • 4
    • 52049119086 scopus 로고    scopus 로고
    • Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility
    • Farah K., Jerbi T., Kuntz F., and Kovacs A. Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility. Radiat. Meas. 41 (2006) 201-208
    • (2006) Radiat. Meas. , vol.41 , pp. 201-208
    • Farah, K.1    Jerbi, T.2    Kuntz, F.3    Kovacs, A.4
  • 5
    • 34248660244 scopus 로고    scopus 로고
    • Effect of post-irradiation thermal treatments on the stability of gamma-irradiated glass dosimeter
    • Farah K., Kovacs A., Mejri A., and Ben Ouada H. Effect of post-irradiation thermal treatments on the stability of gamma-irradiated glass dosimeter. Radiat. Phys. Chem. 76 (2007) 1523-1526
    • (2007) Radiat. Phys. Chem. , vol.76 , pp. 1523-1526
    • Farah, K.1    Kovacs, A.2    Mejri, A.3    Ben Ouada, H.4
  • 6
    • 0021410767 scopus 로고
    • Electron spin resonance studies of trapped hole centers in irradiated alkali silicate glasses: a critical comment to current models for HC1 and HC2
    • Griscom D.L. Electron spin resonance studies of trapped hole centers in irradiated alkali silicate glasses: a critical comment to current models for HC1 and HC2. J. Non-Cryst. Solids 64 (1984) 229-247
    • (1984) J. Non-Cryst. Solids , vol.64 , pp. 229-247
    • Griscom, D.L.1
  • 7
    • 52049107441 scopus 로고    scopus 로고
    • ISO/ASTM, 2002. Standard Guide for Estimating of Uncertainties in Dosimetry for Radiation Processing, ISO/ASTM Standard 51707-2002, American Society for Testing and Materials, Philadelphia, PA.
    • ISO/ASTM, 2002. Standard Guide for Estimating of Uncertainties in Dosimetry for Radiation Processing, ISO/ASTM Standard 51707-2002, American Society for Testing and Materials, Philadelphia, PA.
  • 8
    • 0028804250 scopus 로고
    • Environmental effects on dosimetric properties of commercially available window glass sheets
    • Khan H.M., and Wasim Ali S. Environmental effects on dosimetric properties of commercially available window glass sheets. Radiat. Phys. Chem. 46 (1995) 1203-1206
    • (1995) Radiat. Phys. Chem. , vol.46 , pp. 1203-1206
    • Khan, H.M.1    Wasim Ali, S.2
  • 9
    • 52049101835 scopus 로고    scopus 로고
    • Kuntz, F., Fung, R., Strasser, A., 1999. A dedicated tool for the quality assurance in the field of radiation processing. In: Proceedings of the 11th International Meeting on Radiation Processing, Melbourne, Australia.
    • Kuntz, F., Fung, R., Strasser, A., 1999. A dedicated tool for the quality assurance in the field of radiation processing. In: Proceedings of the 11th International Meeting on Radiation Processing, Melbourne, Australia.
  • 12
    • 0036124583 scopus 로고    scopus 로고
    • Commercial plate window glass tested as a routine dosimeter at a gamma irradiation facility
    • Rodrigues Ary de A. Commercial plate window glass tested as a routine dosimeter at a gamma irradiation facility. Radiat. Phys. Chem. 63 (2002) 765-767
    • (2002) Radiat. Phys. Chem. , vol.63 , pp. 765-767
    • Rodrigues Ary de, A.1
  • 13
    • 0031237384 scopus 로고    scopus 로고
    • Study on the possibility of reading two kinds of data from one glass detector
    • Zheng Z. Study on the possibility of reading two kinds of data from one glass detector. Radiat. Phys. Chem. 50 (1996) 303-305
    • (1996) Radiat. Phys. Chem. , vol.50 , pp. 303-305
    • Zheng, Z.1
  • 14
    • 50849146757 scopus 로고
    • Window glass as a routine dosimeter for radiation processing
    • Zheng Z., Honggui D., Jie F., and Daochuan Y. Window glass as a routine dosimeter for radiation processing. Radiat. Phys. Chem. 31 (1988) 419-423
    • (1988) Radiat. Phys. Chem. , vol.31 , pp. 419-423
    • Zheng, Z.1    Honggui, D.2    Jie, F.3    Daochuan, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.