Selection of a parameter to evaluate wearable cuff-less blood pressure measuring devices

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERICS; BIOSENSORS; BLOOD; BLOOD PRESSURE; CHLORINE COMPOUNDS; HEALTH; SENSORS;

EID: 51949112866     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSMDBS.2008.4575064     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 33750809308 scopus 로고    scopus 로고
    • American National Standard for Manual, Electronic, or Automated Sphygmomanometers
    • Association for the Advancement of Medical Instrumentation
    • Association for the Advancement of Medical Instrumentation, "American National Standard for Manual, Electronic, or Automated Sphygmomanometers," SP10-2002, ANSI/AAMI, 2003.
    • (2003) ANSI/AAMI , vol.SP10-2002
  • 2
    • 0001849046 scopus 로고
    • The British Hypertension Society Protocol for the Evaluation of Blood Pressure Measuring Device
    • E. O'Brien et al., "The British Hypertension Society Protocol for the Evaluation of Blood Pressure Measuring Device," J. of Hypertension, vol. 11(suppl. 2), 1993, pp. S43-S63
    • (1993) J. of Hypertension , vol.11 , Issue.SUPPL. 2
    • O'Brien, E.1
  • 3
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • E.O'Brien et al., "Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults," Blood Pressure Monitoring, vol. 7, 2002, pp. 3-17
    • (2002) Blood Pressure Monitoring , vol.7 , pp. 3-17
    • O'Brien, E.1
  • 4
    • 34547314515 scopus 로고    scopus 로고
    • Modeling of the cuffless blood pressure measurement differences for the evaluation of a wearable medical device
    • Boston, Sept
    • X.Y. Xiang, Carmen C.Y. Poon and Y.T. Zhang, "Modeling of the cuffless blood pressure measurement differences for the evaluation of a wearable medical device," 3rd IEEE/EMBS International Summer School, Boston, Sept. 2006, pp. 105-108.
    • (2006) 3rd IEEE/EMBS International Summer School , pp. 105-108
    • Xiang, X.Y.1    Poon, C.C.Y.2    Zhang, Y.T.3
  • 7
    • 51949087209 scopus 로고    scopus 로고
    • Evaluation of the Wearable Blood Pressure Measurement Devices,
    • M. Phil. Thesis, Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
    • X.Y. Xiang, "Evaluation of the Wearable Blood Pressure Measurement Devices," M. Phil. Thesis, Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China, 2006
    • (2006)
    • Xiang, X.Y.1
  • 9
    • 0002006114 scopus 로고
    • Difference measures for generalizing about forecasting methods: Empirical comparisons
    • June
    • J. Scott Armstrong and Fred Collopy, "Difference measures for generalizing about forecasting methods: empirical comparisons," International Journal of Forecasting, vol. 8 (1), June 1992, pp. 69-80
    • (1992) International Journal of Forecasting , vol.8 , Issue.1 , pp. 69-80
    • Scott Armstrong, J.1    Collopy, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.