Volumn 17, Issue 4, 2001, Pages 257-262

Fibrin sealant: A novel method of fixation for an implantable ultrasonic microDoppler probe

Author keywords

Doppler probe; Fibrin sealant; Microsurgery; Postoperative monitoring

Indexed keywords

BIOMATERIAL; FIBRIN; SEALANT; SILICONE;

EID: 0035005592     PISSN: 0743684X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2001-14517     Document Type: Article
Times cited : (20)

References (26)
  • 1
    • 0020538683 scopus 로고
    • Microvascular free flaps: The first decade
    • Shaw WW. Microvascular free flaps: the first decade. Clin Plast Surg 1983;10:3-20
    • (1983) Clin Plast Surg , vol.10 , pp. 3-20
    • Shaw, W.W.1
  • 2
    • 0031718428 scopus 로고    scopus 로고
    • A review of 716 consecutive free flaps for oncologic surgical defects: Refinement in donor-site selection and technique
    • Hidalgo DA, Disa JJ, Cordeiro PG, Hu QY. A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique. Plast Reconstr Surg 1998;102:722-734
    • (1998) Plast Reconstr Surg , vol.102 , pp. 722-734
    • Hidalgo, D.A.1    Disa, J.J.2    Cordeiro, P.G.3    Hu, Q.Y.4
  • 3
    • 0026701102 scopus 로고
    • Intraoperative and postoperative monitoring of microsurgical free tissue transfers
    • Jones NF. Intraoperative and postoperative monitoring of microsurgical free tissue transfers. Clin Plast Surg 1992;19: 783-797
    • (1992) Clin Plast Surg , vol.19 , pp. 783-797
    • Jones, N.F.1
  • 4
    • 0026081689 scopus 로고
    • Monitoring in microvascular surgery
    • Furnas H, Rosen JM. Monitoring in microvascular surgery. Ann Plast Surg 1991;26:265-272
    • (1991) Ann Plast Surg , vol.26 , pp. 265-272
    • Furnas, H.1    Rosen, J.M.2
  • 6
    • 0027579855 scopus 로고
    • Fibrin sealant adhesive systems: A review of their chemistry, material properties and clinical application
    • Sierra DH. Fibrin sealant adhesive systems: a review of their chemistry, material properties and clinical application. J Biomater Appl 1993;7:309-352
    • (1993) J Biomater Appl , vol.7 , pp. 309-352
    • Sierra, D.H.1
  • 7
    • 0000555270 scopus 로고
    • The use of fluorescein to determine adequacy of circulation
    • Lange K, Boyd LJ. The use of fluorescein to determine adequacy of circulation. Med Clin North Am 1942;26:943-952
    • (1942) Med Clin North Am , vol.26 , pp. 943-952
    • Lange, K.1    Boyd, L.J.2
  • 8
    • 0017184827 scopus 로고
    • The photoelectric plethysmograph as a monitor of microvascular anastomoses
    • Webster MHC, Patterson J. The photoelectric plethysmograph as a monitor of microvascular anastomoses. Br J Plast Surg 1976;29:182-185
    • (1976) Br J Plast Surg , vol.29 , pp. 182-185
    • Webster, M.H.C.1    Patterson, J.2
  • 9
    • 0033971378 scopus 로고    scopus 로고
    • Monitoring free flaps using the laser Doppler flowmeter: Five-year experience
    • Yuen JC, Feng Z. Monitoring free flaps using the laser Doppler flowmeter: five-year experience. Plast Reconstr Surg 2000; 105:55-61
    • (2000) Plast Reconstr Surg , vol.105 , pp. 55-61
    • Yuen, J.C.1    Feng, Z.2
  • 10
    • 0021162516 scopus 로고
    • Implantable pulsed ultrasound Doppler cuff long-term monitoring of free flaps: A preliminary study
    • Parker PM, Fischer JC, Shaw WW. Implantable pulsed ultrasound Doppler cuff long-term monitoring of free flaps: a preliminary study. Microsurgery 1984;5:130-135
    • (1984) Microsurgery , vol.5 , pp. 130-135
    • Parker, P.M.1    Fischer, J.C.2    Shaw, W.W.3
  • 11
    • 0023404481 scopus 로고
    • Direct anastomotic assessment for postoperative microvascular monitoring
    • Roberts JO, Jones BM. Direct anastomotic assessment for postoperative microvascular monitoring. Ann Plast Surg 1987;19:219-224
    • (1987) Ann Plast Surg , vol.19 , pp. 219-224
    • Roberts, J.O.1    Jones, B.M.2
  • 12
    • 0023835477 scopus 로고
    • Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: An experimental and clinical study
    • Swartz WM, Jones NF, Cherup L, Klein A. Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study. Plast Reconstr Surg 1988;81:149-158
    • (1988) Plast Reconstr Surg , vol.81 , pp. 149-158
    • Swartz, W.M.1    Jones, N.F.2    Cherup, L.3    Klein, A.4
  • 13
    • 0028140059 scopus 로고
    • Implantable venous Doppler microvascular monitoring: Laboratory investigation and clinical results
    • Swartz WM, Izquierdo R, Miller MJ. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 1994;93:152-163
    • (1994) Plast Reconstr Surg , vol.93 , pp. 152-163
    • Swartz, W.M.1    Izquierdo, R.2    Miller, M.J.3
  • 14
    • 0031900329 scopus 로고    scopus 로고
    • The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants
    • Kind GM, Buntic RF, Bunke GM, et al. The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants. Plast Reconstr Surg 1998;101:1268-1273
    • (1998) Plast Reconstr Surg , vol.101 , pp. 1268-1273
    • Kind, G.M.1    Buntic, R.F.2    Bunke, G.M.3
  • 15
    • 0026003312 scopus 로고
    • Fibrin glue
    • Brennan M. Fibrin glue. Blood Rev 1991;5:240-244
    • (1991) Blood Rev , vol.5 , pp. 240-244
    • Brennan, M.1
  • 16
    • 84856076583 scopus 로고
    • Uber wirkugen des fibrins
    • Bergel S. Uber Wirkugen des Fibrins. Dtsch Med Wochenschr 1909;35:633-665
    • (1909) Dtsch Med Wochenschr , vol.35 , pp. 633-665
    • Bergel, S.1
  • 17
    • 50349140510 scopus 로고
    • Fibrin suture of peripheral nerves
    • Young JZ, Medawar PB. Fibrin suture of peripheral nerves. Lancet 1940;275:126-132
    • (1940) Lancet , vol.275 , pp. 126-132
    • Young, J.Z.1    Medawar, P.B.2
  • 18
    • 0029125992 scopus 로고
    • Fibrin sealant in the United States: Clinical use at the University of Virginia
    • Spotnitz WD. Fibrin sealant in the United States: clinical use at the University of Virginia. Thromb Haemost 1995;74: 482-485
    • (1995) Thromb Haemost , vol.74 , pp. 482-485
    • Spotnitz, W.D.1
  • 19
    • 0032936271 scopus 로고    scopus 로고
    • Mesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute: Technical note
    • Nagata K, Kawamoto S, Sashida J, et al. Mesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute: technical note. Neurol Med Chir (Tokyo) 1999;39:316
    • (1999) Neurol Med Chir (Tokyo) , vol.39 , pp. 316
    • Nagata, K.1    Kawamoto, S.2    Sashida, J.3
  • 20
    • 0030952755 scopus 로고    scopus 로고
    • Masking the protrusion of the receiver-stimulator of electronic implants in otology
    • Gyo K, Sato H, Yumoto E, et al. Masking the protrusion of the receiver-stimulator of electronic implants in otology. Ear Nose Throat J 1997;76:316-320
    • (1997) Ear Nose Throat J , vol.76 , pp. 316-320
    • Gyo, K.1    Sato, H.2    Yumoto, E.3
  • 21
    • 0025781488 scopus 로고
    • Alveolar ridge augmentation with hydroxylapatite using fibrin sealant for fixation. Part I: An experimental study
    • Hotz G. Alveolar ridge augmentation with hydroxylapatite using fibrin sealant for fixation. Part I: An experimental study. Int J Oral Maxillofac Surg 1991;20:204-207
    • (1991) Int J Oral Maxillofac Surg , vol.20 , pp. 204-207
    • Hotz, G.1
  • 22
    • 0031419025 scopus 로고    scopus 로고
    • A new method of hemostasis for cementless total knee arthroplasty
    • Akizuki S, Yasukawa Y, Takizawa T. A new method of hemostasis for cementless total knee arthroplasty. Bull Hosp Jt Dis 1997;56:222-224
    • (1997) Bull Hosp Jt Dis , vol.56 , pp. 222-224
    • Akizuki, S.1    Yasukawa, Y.2    Takizawa, T.3
  • 23
    • 0020262743 scopus 로고
    • Direct microvascular monitoring with implantable ultrasonic Doppler probes
    • Pinnella JW, Spira M, Erk Y, et al. Direct microvascular monitoring with implantable ultrasonic Doppler probes. J Microsurg 1982;3:217-221
    • (1982) J Microsurg , vol.3 , pp. 217-221
    • Pinnella, J.W.1    Spira, M.2    Erk, Y.3
  • 24
    • 0030853266 scopus 로고    scopus 로고
    • A new method of applying fibrin glue at the microvascular anastomotic site: The "paintbrush" technique
    • Padubidri AN, Browne E. A new method of applying fibrin glue at the microvascular anastomotic site: the "paintbrush" technique. Microsurgery 1996;17:428-430
    • (1996) Microsurgery , vol.17 , pp. 428-430
    • Padubidri, A.N.1    Browne, E.2
  • 25
    • 0029950387 scopus 로고    scopus 로고
    • Clinical outcome of digital replantation using the fibrin glue-assisted microvascular anastomosis technique
    • Isogai N, Cooley BG, Kamiishi H. Clinical outcome of digital replantation using the fibrin glue-assisted microvascular anastomosis technique. J Hand Surg 1996;21B:573-575
    • (1996) J Hand Surg , vol.21 B , pp. 573-575
    • Isogai, N.1    Cooley, B.G.2    Kamiishi, H.3
  • 26
    • 0031692781 scopus 로고    scopus 로고
    • Acute thrombogenic effects of fibrin sealant on microvascular anastomoses in a rat model
    • Marek CA, Amiss LR Jr, Morgan RF, et al. Acute thrombogenic effects of fibrin sealant on microvascular anastomoses in a rat model. Ann Plast Surg 1998;41:415-419
    • (1998) Ann Plast Surg , vol.41 , pp. 415-419
    • Marek, C.A.1    Amiss L.R., Jr.2    Morgan, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.