메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 144-149

Influence of blood specimen collection method on various preanalytical sample quality indicators

Author keywords

Hemolysis; Needle and syringe; Open collection; Preanalytical; Total quality; Vacutainer

Indexed keywords

ANALYTICAL ERROR; ARTICLE; BLOOD ANALYSIS; BLOOD SAMPLING; DEVICE; HEMOLYSIS; HUMAN; INFORMATION SYSTEM; LABORATORY TEST; NEEDLE; QUALITY CONTROL; SYRINGE;

EID: 51349101692     PISSN: 09701915     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12291-008-0032-4     Document Type: Article
Times cited : (7)

References (16)
  • 1
    • 0025854104 scopus 로고
    • Putting bar codes to work for improved patient care
    • Weilert M, Tilzer LL. Putting bar codes to work for improved patient care. Clin Lab Med 1991; 11:227-30.
    • (1991) Clin Lab Med , vol.11 , pp. 227-230
    • Weilert, M.1    Tilzer, L.L.2
  • 3
    • 0020029548 scopus 로고
    • The effects of inaccurate blood sample volume on prothrombin time (PT) and activated partial thromboplastin time (aPTT)
    • Peterson P, Gottfried EL. The effects of inaccurate blood sample volume on prothrombin time (PT) and activated partial thromboplastin time (aPTT). Thrombosis and Haemostasis 1982; 47:101-3.
    • (1982) Thrombosis and Haemostasis , vol.47 , pp. 101-103
    • Peterson, P.1    Gottfried, E.L.2
  • 4
    • 0031862104 scopus 로고    scopus 로고
    • Prolonged prothrombin time and activated partial thromboplastin time due to filled specimen tubes with 109 mmo1/L (3.2%) citrate anticoagulant
    • Reneke J, Etzell J, Leslie S, Ng VL, Gottfried EL. Prolonged prothrombin time and activated partial thromboplastin time due to filled specimen tubes with 109 mmo1/L (3.2%) citrate anticoagulant. Am J Clin Pathol 1998;109:754-7
    • (1998) Am J Clin Pathol , vol.109 , pp. 754-757
    • Reneke, J.1    Etzell, J.2    Leslie, S.3    Ng, V.L.4    Gottfried, E.L.5
  • 5
    • 17444444102 scopus 로고
    • Recommended "order of draw" for collecting blood specimens into additive-containing tubes
    • Calam RR, Cooper MH. Recommended "order of draw" for collecting blood specimens into additive-containing tubes. Clin Chem 1982; 28:1399-401.
    • (1982) Clin Chem , vol.28 , pp. 1399-1401
    • Calam, R.R.1    Cooper, M.H.2
  • 8
    • 0000295115 scopus 로고
    • A cause of erroneous potassium levels
    • Skinner SL, Adelaide MB. A cause of erroneous potassium levels. Lancet 1961; 1: 478-80.
    • (1961) Lancet , vol.1 , pp. 478-480
    • Skinner, S.L.1    Adelaide, M.B.2
  • 9
    • 51349156419 scopus 로고    scopus 로고
    • Lawrence AK, Amadeo JP Steven CK. Clinical Chemistry 2003: Theory, analysis, correlation: Fourth Edition.
    • Lawrence AK, Amadeo JP Steven CK. Clinical Chemistry 2003: Theory, analysis, correlation: Fourth Edition.
  • 14
    • 0030797124 scopus 로고    scopus 로고
    • Mistakes and stat laboratory: Types and frequency
    • Plebani M, Carraro P. Mistakes and stat laboratory: types and frequency. Clin Chem 1997; 43: 1348-51.
    • (1997) Clin Chem , vol.43 , pp. 1348-1351
    • Plebani, M.1    Carraro, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.