Volumn 5116 LNCS, Issue , 2008, Pages 724-731

Comparative technical study of two generations of CR plates for digital mammography

Author keywords

Computed radiography; Contrast detail; Digital mammography

Indexed keywords

BEAM QUALITY; COMPUTER NETWORKS; DIAGNOSTIC RADIOGRAPHY; IMAGE QUALITY; OPTICAL PROPERTIES;

EID: 50949129491     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-70538-3_100     Document Type: Conference Paper
Times cited : (1)

References (9)
  • 1
    • 0003958580 scopus 로고    scopus 로고
    • The European protocol for the quality control of the physical and technical aspects of mammography screening. Part B
    • 4th edn
    • van Engen, R., et al.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Part B In: European Guidelines for Breast Cancer Screening, 4th edn. (2006)
    • (2006) European Guidelines for Breast Cancer Screening
    • van Engen, R.1
  • 2
    • 33745416524 scopus 로고    scopus 로고
    • Young, K.C., et al.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: SPIE, 614206, pp. 1-is (2006)
    • Young, K.C., et al.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: SPIE, vol. 614206, pp. 1-is (2006)
  • 3
    • 34347399809 scopus 로고    scopus 로고
    • Physical characteristics of five clinical systems for digital mammography
    • Lazzari, B., Gori, C., Rosselli Del Turco, M.: Physical characteristics of five clinical systems for digital mammography. Med. Phys. 34(7), 2730-2743 (2007)
    • (2007) Med. Phys , vol.34 , Issue.7 , pp. 2730-2743
    • Lazzari, B.1    Gori, C.2    Rosselli Del Turco, M.3
  • 4
    • 35848968890 scopus 로고    scopus 로고
    • Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems
    • Marshall, N.W.: Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems. Phys. Med. Biol. 52(18), 5545-5568 (2007)
    • (2007) Phys. Med. Biol , vol.52 , Issue.18 , pp. 5545-5568
    • Marshall, N.W.1
  • 5
    • 33847645786 scopus 로고    scopus 로고
    • A comparison of the performance of digital mammography systems
    • Monnin, P., Gutierrez, D., Bulling, S., Guntern, D., Verdun, F.R.: A comparison of the performance of digital mammography systems. Med. Phys. 34(3), 906-914 (2007)
    • (2007) Med. Phys , vol.34 , Issue.3 , pp. 906-914
    • Monnin, P.1    Gutierrez, D.2    Bulling, S.3    Guntern, D.4    Verdun, F.R.5
  • 6
    • 0024560130 scopus 로고
    • Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions
    • Ohara, K., et al.: Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions. Med. Phys. 16(1), 14-21 (1989)
    • (1989) Med. Phys , vol.16 , Issue.1 , pp. 14-21
    • Ohara, K.1
  • 8
    • 21144458392 scopus 로고    scopus 로고
    • Validation of MTF measurement for digital mammography quality control
    • Carton, A.K., et al.: Validation of MTF measurement for digital mammography quality control. Med. Phys. 6, 1684-1695 (2005)
    • (2005) Med. Phys , vol.6 , pp. 1684-1695
    • Carton, A.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.