메뉴 건너뛰기




Volumn 1274, Issue C, 2004, Pages 23-32

An overview of bone sonometry

Author keywords

Bone; BUA; Osteoporosis; Speed of sound; Ultrasound

Indexed keywords


EID: 50949105327     PISSN: 05315131     EISSN: None     Source Type: Book Series    
DOI: 10.1016/j.ics.2004.07.034     Document Type: Article
Times cited : (36)

References (30)
  • 1
    • 0030934375 scopus 로고    scopus 로고
    • In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images
    • C.L. Gordon In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images Med. Phys. 24 1997 585 593
    • (1997) Med. Phys. , vol.24 , pp. 585-593
    • Gordon, C.L.1
  • 2
    • 0029970805 scopus 로고    scopus 로고
    • In vivo reproducibility of three-dimensional structural properties of non-invasive bone biopsies using 3D-pQCT
    • R. Müller In vivo reproducibility of three-dimensional structural properties of non-invasive bone biopsies using 3D-pQCT J. Bone Miner. Res. 11 1996 1745 1750
    • (1996) J. Bone Miner. Res. , vol.11 , pp. 1745-1750
    • Müller, R.1
  • 3
    • 0003846039 scopus 로고    scopus 로고
    • Quantitative Ultrasound
    • C. Njeh Quantitative Ultrasound Assessment of Osteoporosis and Bone Status 1999 Martin Dunitz London
    • (1999)
    • Njeh, C.1
  • 4
    • 0021408517 scopus 로고
    • The measurement of broadband ultrasonic attenuation in cancellous bone
    • C.M. Langton S.B. Palmer S.W. Porter The measurement of broadband ultrasonic attenuation in cancellous bone Eng. Med. 13 1984 89 91
    • (1984) Eng. Med. , vol.13 , pp. 89-91
    • Langton, C.M.1    Palmer, S.B.2    Porter, S.W.3
  • 5
    • 0029980204 scopus 로고    scopus 로고
    • Ultrasound velocity measured at the proximal phalanges: precision and age-related changes in normal females
    • F. Duboeuf Ultrasound velocity measured at the proximal phalanges: precision and age-related changes in normal females Rev. Rhum. (Engl. ed.) 63 1996 427 434
    • (1996) Rev. Rhum. (Engl. ed.) , vol.63 , pp. 427-434
    • Duboeuf, F.1
  • 6
    • 0028886520 scopus 로고
    • Quantitative, ultrasound of the tibia: a novel approach for assessment of bone status
    • J. Foldes Quantitative, ultrasound of the tibia: a novel approach for assessment of bone status Bone 17 1995 363 367
    • (1995) Bone , vol.17 , pp. 363-367
    • Foldes, J.1
  • 7
    • 0033002460 scopus 로고    scopus 로고
    • Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?
    • D. Hans Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture? J. Bone Miner. Res. 14 1999 644 651
    • (1999) J. Bone Miner. Res. , vol.14 , pp. 644-651
    • Hans, D.1
  • 8
    • 0027528522 scopus 로고
    • Measurement of intrinsic bone quality in vivo by reflection ultrasound: correction of impaired quality with slow-release sodium fluoride and calcium citrate
    • P. Antich Measurement of intrinsic bone quality in vivo by reflection ultrasound: correction of impaired quality with slow-release sodium fluoride and calcium citrate J. Bone Miner. Res. 8 1993 301 311
    • (1993) J. Bone Miner. Res. , vol.8 , pp. 301-311
    • Antich, P.1
  • 9
    • 0034976172 scopus 로고    scopus 로고
    • Ultrasonic backscatter and transmission parameters at the os calcis in post-menopausal osteoporosis
    • C. Roux Ultrasonic backscatter and transmission parameters at the os calcis in post-menopausal osteoporosis J. Bone Miner. Res. 16 2001 1353 1362
    • (2001) J. Bone Miner. Res. , vol.16 , pp. 1353-1362
    • Roux, C.1
  • 10
    • 1842858991 scopus 로고    scopus 로고
    • Guided ultrasonic waves in long bones: modelling, experiment and application
    • P. Nicholson Guided ultrasonic waves in long bones: modelling, experiment and application Physiol. Meas. 23 2002 755 768
    • (2002) Physiol. Meas. , vol.23 , pp. 755-768
    • Nicholson, P.1
  • 11
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and QCT
    • P. Laugier In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and QCT Bone 20 1997 157 165
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1
  • 12
    • 0030741752 scopus 로고    scopus 로고
    • Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    • C. Chappard Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA Osteoporos. Int. 7 1997 316 322
    • (1997) Osteoporos. Int. , vol.7 , pp. 316-322
    • Chappard, C.1
  • 13
    • 85120217237 scopus 로고    scopus 로고
    • http://www.hologic.com/prod-bd/prod-sahara.shtml .
  • 14
    • 0029779557 scopus 로고    scopus 로고
    • Broadband ultrasonic attenuation imaging: a new imaging method in osteoporosis
    • C. Roux Broadband ultrasonic attenuation imaging: a new imaging method in osteoporosis J. Bone Miner. Res. 11 1996 1112 1118
    • (1996) J. Bone Miner. Res. , vol.11 , pp. 1112-1118
    • Roux, C.1
  • 15
    • 85120232224 scopus 로고    scopus 로고
    • http://www.gemedicalsystemseurope.com/euen/rad/bonedens/achilles/insight.html .
  • 16
    • 0036814824 scopus 로고    scopus 로고
    • In vivo performance of a matrix-based quantitative ultrasound imaging device dedicated to calcaneus investigation
    • M.A. Gomez In vivo performance of a matrix-based quantitative ultrasound imaging device dedicated to calcaneus investigation Ultrasound Med. Biol. 28 2002 1285 1293
    • (2002) Ultrasound Med. Biol. , vol.28 , pp. 1285-1293
    • Gomez, M.A.1
  • 17
    • 1342324684 scopus 로고    scopus 로고
    • Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials
    • E. Bossy Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials IEEE Trans. Ultrason. Ferroelectr. Freq. Control 51 2004 71 79
    • (2004) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.51 , pp. 71-79
    • Bossy, E.1
  • 18
    • 0030858059 scopus 로고    scopus 로고
    • The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro
    • R. Hodgskinson The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro Bone 21 1997 183 190
    • (1997) Bone , vol.21 , pp. 183-190
    • Hodgskinson, R.1
  • 19
    • 0030176206 scopus 로고    scopus 로고
    • Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation
    • C.M. Langton Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation Bone 18 1996 495 503
    • (1996) Bone , vol.18 , pp. 495-503
    • Langton, C.M.1
  • 20
    • 0031027689 scopus 로고    scopus 로고
    • Ultrasound velocity and broadband attenuation as predictors of load-bearing capacities of human calcanei
    • S. Han Ultrasound velocity and broadband attenuation as predictors of load-bearing capacities of human calcanei Calcif. Tissue Int. 60 1997 21 25
    • (1997) Calcif. Tissue Int. , vol.60 , pp. 21-25
    • Han, S.1
  • 21
    • 0031712607 scopus 로고    scopus 로고
    • Prediction of vertebral and femoral strength in vitro by bone mineral density measured at different skeletal sites
    • X.G. Cheng Prediction of vertebral and femoral strength in vitro by bone mineral density measured at different skeletal sites J. Bone Miner. Res. 13 1998 1439 1443
    • (1998) J. Bone Miner. Res. , vol.13 , pp. 1439-1443
    • Cheng, X.G.1
  • 22
    • 0030932953 scopus 로고    scopus 로고
    • The epidemiology of quantitative ultrasound: a review of the relationships with bone mass, osteoporosis and fracture risk
    • E.W. Gregg The epidemiology of quantitative ultrasound: a review of the relationships with bone mass, osteoporosis and fracture risk Osteoporos. Int. 7 1997 89 99
    • (1997) Osteoporos. Int. , vol.7 , pp. 89-99
    • Gregg, E.W.1
  • 23
    • 16044362010 scopus 로고    scopus 로고
    • Ultrasonographic heel measurements to predict hip fracture in elderly women: the Epidos prospective study
    • D. Hans Ultrasonographic heel measurements to predict hip fracture in elderly women: the Epidos prospective study Lancet 348 1996 511 514
    • (1996) Lancet , vol.348 , pp. 511-514
    • Hans, D.1
  • 24
    • 0030934837 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women
    • D.C. Bauer Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women Arch. Intern. Med. 157 1997 629 634
    • (1997) Arch. Intern. Med. , vol.157 , pp. 629-634
    • Bauer, D.C.1
  • 25
    • 1642452734 scopus 로고    scopus 로고
    • Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study
    • K.-T. Khaw Prediction of total and hip fracture risk in men and women by quantitative ultrasound of the calcaneus: EPIC-Norfolk prospective population study Lancet 363 2004 197 202
    • (2004) Lancet , vol.363 , pp. 197-202
    • Khaw, K.-T.1
  • 27
    • 3242806167 scopus 로고    scopus 로고
    • Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample: the OPUS study
    • C.C. Glüer Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample: the OPUS study J. Bone Miner. Res. 19 2004 782 793
    • (2004) J. Bone Miner. Res. , vol.19 , pp. 782-793
    • Glüer, C.C.1
  • 28
    • 79955403443 scopus 로고    scopus 로고
    • Osteoporosis screening for high and low risk patients using heel ultrasound
    • P.K. Burke Osteoporosis screening for high and low risk patients using heel ultrasound Osteoporos. Int. 15 2004 S40
    • (2004) Osteoporos. Int. , vol.15 , pp. S40
    • Burke, P.K.1
  • 29
    • 34548119248 scopus 로고    scopus 로고
    • Osteoporosis screening: comparison of the heel ultrasound measurement to calculated risk assessment tools
    • M. Gambacciani A.R. Genazzani Osteoporosis screening: comparison of the heel ultrasound measurement to calculated risk assessment tools Osteoporos. Int. 15 2004 S36
    • (2004) Osteoporos. Int. , vol.15 , pp. S36
    • Gambacciani, M.1    Genazzani, A.R.2
  • 30
    • 0036150530 scopus 로고    scopus 로고
    • Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-base sample of postmenopausal women with vertebral fractures: results of the Basel osteoporosis study
    • F. Hartl Discriminatory ability of quantitative ultrasound parameters and bone mineral density in a population-base sample of postmenopausal women with vertebral fractures: results of the Basel osteoporosis study J. Bone Miner. Res. 17 2002 321 330
    • (2002) J. Bone Miner. Res. , vol.17 , pp. 321-330
    • Hartl, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.