메뉴 건너뛰기




Volumn 28, Issue 10, 2002, Pages 1285-1293

In vivo performance of a matrix-based quantitative ultrasound imaging device dedicated to calcaneus investigation

Author keywords

Attenuation; Calcaneus; Matrix; Osteoporosis; Speed of sound; Ultrasound

Indexed keywords

ATTENUATION; DENSITOMETERS; SPACE RESEARCH;

EID: 0036814824     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(02)00616-6     Document Type: Article
Times cited : (25)

References (24)
  • 1
    • 0002470583 scopus 로고    scopus 로고
    • Factors influencing QUS parameters of the calcaneum; Suggestions for an improved measurement procedure
    • Barkmann R., Glüer C. Factors influencing QUS parameters of the calcaneum; suggestions for an improved measurement procedure. J Clin Densitom. 1:1998;93-94.
    • (1998) J Clin Densitom , vol.1 , pp. 93-94
    • Barkmann, R.1    Glüer, C.2
  • 2
    • 0032934185 scopus 로고    scopus 로고
    • Ultrasound measurement on the calcaneus: Influence of immersion time and rotation of the foot
    • Chappard C., Berger G., Roux C., Laugier P. Ultrasound measurement on the calcaneus Influence of immersion time and rotation of the foot . Osteoporos Int. 9:1999;318-326.
    • (1999) Osteoporos Int , vol.9 , pp. 318-326
    • Chappard, C.1    Berger, G.2    Roux, C.3    Laugier, P.4
  • 3
    • 0033293677 scopus 로고    scopus 로고
    • A prototype of a 500 kHz ultrasonic matricial device: BEAM SCANNER. Application to in-vivo heel bone quantitative characterization
    • Defontaine M., Certon D., Colin L., et al. A prototype of a 500 kHz ultrasonic matricial device BEAM SCANNER. Application to in-vivo heel bone quantitative characterization . IEEE Ultrason Sympos Proc. 2:1999;1585-1588.
    • (1999) IEEE Ultrason Sympos Proc , vol.2 , pp. 1585-1588
    • Defontaine, M.1    Certon, D.2    Colin, L.3
  • 5
    • 0028893126 scopus 로고
    • Factors affecting the in vivo precision of broadband ultrasonic attenuation
    • Evans W., Jones E., Owen G. Factors affecting the in vivo precision of broadband ultrasonic attenuation. Phys Med Biol. 40:1995;137-151.
    • (1995) Phys Med Biol , vol.40 , pp. 137-151
    • Evans, W.1    Jones, E.2    Owen, G.3
  • 6
    • 0030825428 scopus 로고    scopus 로고
    • Quantitative ultrasound imaging at the calcaneus using an automatic region of interest
    • Fournier B., Chappard C., Roux C., Berger G., Laugier P. Quantitative ultrasound imaging at the calcaneus using an automatic region of interest. Osteoporos Int. 7:1997;363-369.
    • (1997) Osteoporos Int , vol.7 , pp. 363-369
    • Fournier, B.1    Chappard, C.2    Roux, C.3    Berger, G.4    Laugier, P.5
  • 7
    • 0012416831 scopus 로고    scopus 로고
    • Quality assurance and quality control in quantitative ultrasound
    • C. InNjeh, D. Hans, T. Fuerst, C. Glüer, & H. Genant. London: Nartin Dunitz. 163:
    • Fuerst T., Njeh C., Hans D. Quality assurance and quality control in quantitative ultrasound. InNjeh C., Hans D., Fuerst T., Glüer C., Genant H. Quantitative Ultrasound Assessment of Osteoporosis and bone status. 1999;75 Nartin Dunitz, London. 163:
    • (1999) Quantitative Ultrasound Assessment of Osteoporosis and bone status , pp. 75
    • Fuerst, T.1    Njeh, C.2    Hans, D.3
  • 8
    • 0030737927 scopus 로고    scopus 로고
    • Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status. The International Quantitative Ultrasound Consensus Group
    • Glüer C. Quantitative ultrasound techniques for the assessment of osteoporosis Expert agreement on current status. The International Quantitative Ultrasound Consensus Group . J Bone Miner Res. 12:1997;1280-1288.
    • (1997) J Bone Miner Res , vol.12 , pp. 1280-1288
    • Glüer, C.1
  • 9
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproductibility of bone densitometry techniques
    • Glüer C., Blake G., Lu Y., et al. Accurate assessment of precision errors How to measure the reproductibility of bone densitometry techniques . Osteoporos Int. 5:1995;262-270.
    • (1995) Osteoporos Int , vol.5 , pp. 262-270
    • Glüer, C.1    Blake, G.2    Lu, Y.3
  • 10
    • 0027198066 scopus 로고
    • Measurements of post menopausal bone loss with a new contact ultrasound system
    • Herd R., Blake G., Ramalingam T., et al. Measurements of post menopausal bone loss with a new contact ultrasound system. Calcif Tissue Int. 53:1993;153-157.
    • (1993) Calcif Tissue Int , vol.53 , pp. 153-157
    • Herd, R.1    Blake, G.2    Ramalingam, T.3
  • 11
    • 0032933059 scopus 로고    scopus 로고
    • Evaluation of a new calcaneal quantitative ultrasound system and determination of normative ultrasound values in southern Chinese women
    • Kung A., Tang G., Luk K., Chu L. Evaluation of a new calcaneal quantitative ultrasound system and determination of normative ultrasound values in southern Chinese women. Osteoporos Int. 9:1999;312-317.
    • (1999) Osteoporos Int , vol.9 , pp. 312-317
    • Kung, A.1    Tang, G.2    Luk, K.3    Chu, L.4
  • 12
    • 0025470090 scopus 로고
    • A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone
    • Langton C., Ali A., Riggs C., Evans G., Bonfield W. A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone. Clin Phys Physiol Measure. 11:1990;243-249.
    • (1990) Clin Phys Physiol Measure , vol.11 , pp. 243-249
    • Langton, C.1    Ali, A.2    Riggs, C.3    Evans, G.4    Bonfield, W.5
  • 13
    • 0021408517 scopus 로고
    • The measurement of broadband ultrasonic attenuation in cancellous bone
    • Langton C., Palmer S., Porter R. The measurement of broadband ultrasonic attenuation in cancellous bone. Eng Med. 13:1984;89-91.
    • (1984) Eng Med , vol.13 , pp. 89-91
    • Langton, C.1    Palmer, S.2    Porter, R.3
  • 14
    • 0029865461 scopus 로고    scopus 로고
    • Ultrasound parametric imaging of the calcaneus: In vivo results with a new device
    • Laugier P., Fournier B., Berger G. Ultrasound parametric imaging of the calcaneus In vivo results with a new device . Calcif Tissue Int. 58:1996;326-331.
    • (1996) Calcif Tissue Int , vol.58 , pp. 326-331
    • Laugier, P.1    Fournier, B.2    Berger, G.3
  • 15
    • 0031040692 scopus 로고    scopus 로고
    • The role of ultrasound in the assessment of osteoporosis: A review
    • Njeh C., Boivin C., Langton C. The role of ultrasound in the assessment of osteoporosis A review . Osteoporos Int. 7:1997;7-22.
    • (1997) Osteoporos Int , vol.7 , pp. 7-22
    • Njeh, C.1    Boivin, C.2    Langton, C.3
  • 16
    • 0035158216 scopus 로고    scopus 로고
    • Evaluation of a gel-coupled quantitative ultrasound device for bone status assessment
    • Njeh C., Chen M., Fan B., et al. Evaluation of a gel-coupled quantitative ultrasound device for bone status assessment. J Ultrasound Med. 11:2001;1219-1228.
    • (2001) J Ultrasound Med , vol.11 , pp. 1219-1228
    • Njeh, C.1    Chen, M.2    Fan, B.3
  • 17
    • 0034483968 scopus 로고    scopus 로고
    • Comparison of six calcaneal quantitative ultrasound devices: Precision and hip fracture discrimination
    • Njeh C., Hans D., Li J. Comparison of six calcaneal quantitative ultrasound devices Precision and hip fracture discrimination . Osteoporos Int. 11:2000;1051-1062.
    • (2000) Osteoporos Int , vol.11 , pp. 1051-1062
    • Njeh, C.1    Hans, D.2    Li, J.3
  • 18
    • 0011905455 scopus 로고
    • A comparison of three commercial bone ultrasound scanners
    • Ramalingam T., Herd R., Lees B., et al. A comparison of three commercial bone ultrasound scanners. Calcif Tissue Int. 52:1993;170.
    • (1993) Calcif Tissue Int , vol.52 , pp. 170
    • Ramalingam, T.1    Herd, R.2    Lees, B.3
  • 19
    • 0033922432 scopus 로고    scopus 로고
    • Quantitative ultrasound in postmenopausal osteoporosis
    • Roux C., Dougados M. Quantitative ultrasound in postmenopausal osteoporosis. Curr Opin Rheumatol. 12:2000;336-345.
    • (2000) Curr Opin Rheumatol , vol.12 , pp. 336-345
    • Roux, C.1    Dougados, M.2
  • 20
    • 0029779557 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation imaging: A new imaging method in osteoporosis
    • Roux C., Fournier B., Laugier P., et al. Broadband ultrasound attenuation imaging A new imaging method in osteoporosis . J Bone Miner Res. 11:1996;1112-1118.
    • (1996) J Bone Miner Res , vol.11 , pp. 1112-1118
    • Roux, C.1    Fournier, B.2    Laugier, P.3
  • 21
    • 0027771493 scopus 로고
    • Broadband ultrasound attenuation of the calcaneus and bone density measurements
    • Roux C., Lemonnier E., Kolta S., et al. Broadband ultrasound attenuation of the calcaneus and bone density measurements. Rev Rhum (English ed.). 60:1993;771-780.
    • (1993) Rev Rhum (English ed.) , vol.60 , pp. 771-780
    • Roux, C.1    Lemonnier, E.2    Kolta, S.3
  • 22
    • 0028085155 scopus 로고
    • Comparison of broadband ultrasound attenuation to single X-ray absorptiometry measurements at the calcaneus in post menopausal women
    • Salamone L., Krall E., Harris S., Dawson-Hughes B. Comparison of broadband ultrasound attenuation to single X-ray absorptiometry measurements at the calcaneus in post menopausal women. Calcif Tissue Int. 54:1994;87-90.
    • (1994) Calcif Tissue Int , vol.54 , pp. 87-90
    • Salamone, L.1    Krall, E.2    Harris, S.3    Dawson-Hughes, B.4
  • 23
    • 0003073167 scopus 로고
    • Using ultrasound for bone densitometry in space:The BDM instrument
    • Schmidt-Harms C, Boutry P, Dubois I, et al. Using ultrasound for bone densitometry in space:The BDM instrument. Microgravity News 1995;8:2-6.
    • (1995) Microgravity News , vol.8 , pp. 2-6
    • Schmidt-Harms, C.1    Boutry, P.2    Dubois, I.3
  • 24
    • 0028224218 scopus 로고
    • Broadband ultrasound attenuation and dual X-ray absorptiometry in patients with hip fractures: Which technique discriminates fracture risk?
    • Stewart A., Reid D., Porter R. Broadband ultrasound attenuation and dual X-ray absorptiometry in patients with hip fractures Which technique discriminates fracture risk? Calcif Tissue Int. 54:1994;466-469.
    • (1994) Calcif Tissue Int , vol.54 , pp. 466-469
    • Stewart, A.1    Reid, D.2    Porter, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.