메뉴 건너뛰기




Volumn 5116 LNCS, Issue , 2008, Pages 716-723

Effect of anode/filter combination on the dose and image quality of a digital mammography system based on an amorphous selenium detector

Author keywords

Contrast to noise ratio; Digital mammography; Image Quality

Indexed keywords

COMPUTER NETWORKS; DIAGNOSTIC RADIOGRAPHY; DIGITAL ARITHMETIC; IMAGE QUALITY; SELENIUM; TUNGSTEN;

EID: 50949090137     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-70538-3_99     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 1
    • 0033693797 scopus 로고    scopus 로고
    • Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: A Monte Carlo study
    • Dance, D.R., Thilander Klang, A., Sandborg, M., Skinner, C.L., Castellano Smith, I.A., Carlsson, G.A.: Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study. Br. J. Radiol. 73, 1056-1067 (2000)
    • (2000) Br. J. Radiol , vol.73 , pp. 1056-1067
    • Dance, D.R.1    Thilander Klang, A.2    Sandborg, M.3    Skinner, C.L.4    Castellano Smith, I.A.5    Carlsson, G.A.6
  • 2
    • 33745393884 scopus 로고    scopus 로고
    • Optimization of tungsten x-ray spectra for digital mammography: A comparison of model to experiment
    • Andre, M.P., Spivey, B. A.: Optimization of tungsten x-ray spectra for digital mammography: a comparison of model to experiment. In: Proc. SPIE, vol. 3032, pp. 411-418 (1997)
    • (1997) Proc. SPIE , vol.3032 , pp. 411-418
    • Andre, M.P.1    Spivey, B.A.2
  • 3
    • 0028001034 scopus 로고
    • Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness and lesion type
    • Fahrig, R., Yaffe, M.J.: Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness and lesion type. Med. Phys 21, 1473-1481 (1994)
    • (1994) Med. Phys , vol.21 , pp. 1473-1481
    • Fahrig, R.1    Yaffe, M.J.2
  • 4
    • 0028145652 scopus 로고
    • A model for optimization of spectral shape in digital mammography
    • Fahrig, R., Yaffe, M. J.: A model for optimization of spectral shape in digital mammography. Med. Phys 21, 1463-1471 (1994)
    • (1994) Med. Phys , vol.21 , pp. 1463-1471
    • Fahrig, R.1    Yaffe, M.J.2
  • 5
    • 0042878300 scopus 로고    scopus 로고
    • Optimal radiographic techniques for digital mammograms obtained with an amorphous selenium detector
    • Flynn, M., Dodge, C., Peck, D., Swinford, A.: Optimal radiographic techniques for digital mammograms obtained with an amorphous selenium detector. In: Proc. SPIE, vol. 5030, pp. 147-156 (2003)
    • (2003) Proc. SPIE , vol.5030 , pp. 147-156
    • Flynn, M.1    Dodge, C.2    Peck, D.3    Swinford, A.4
  • 6
    • 33750547597 scopus 로고    scopus 로고
    • X-ray spectrum optimization of full-digital mammography: Simulation and phantom study
    • Bernhardt, P., Mertelmeier, T., Hoheisel, M.: X-ray spectrum optimization of full-digital mammography: simulation and phantom study. Med. Phys. 33, 4337-4349 (2006)
    • (2006) Med. Phys , vol.33 , pp. 4337-4349
    • Bernhardt, P.1    Mertelmeier, T.2    Hoheisel, M.3
  • 8
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • Dance, D.R., Skinner, C.L., Young, K.C., Beckett, J.R., Kotre, C.J.: Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys. Med. Biol. 45, 3225-3240 (2000)
    • (2000) Phys. Med. Biol , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.