-
2
-
-
0017793932
-
Ultrasonic fragmentation for cataract extraction and cataract complications
-
Girard LJ. Ultrasonic fragmentation for cataract extraction and cataract complications. Adv Ophthalmol 1978; 37: 127-35.
-
(1978)
Adv Ophthalmol
, vol.37
, pp. 127-135
-
-
Girard, L.J.1
-
3
-
-
29844445212
-
Update on bimanual microincisional cataract surgery
-
Weikert MP. Update on bimanual microincisional cataract surgery. Curr Opin Ophthalmol 2006; 17: 62-7.
-
(2006)
Curr Opin Ophthalmol
, vol.17
, pp. 62-67
-
-
Weikert, M.P.1
-
4
-
-
27444431979
-
Phakonit: A new technique of removing cataract through a 0.9mm incision
-
In: Agarwal S, Agarwal A, Sachdev MS etal., eds. 1st Edn. New Delhi: Jaypee Brothers
-
Argarwal A, Argarwal S, Argarwal A. Phakonit: A new technique of removing cataract through a 0.9mm incision. In: Agarwal S, Agarwal A, Sachdev MS etal., eds. Phacoemulsification, Laser Cataract Surgery and Foldable IOLs, 1st Edn. New Delhi: Jaypee Brothers, 1998; 139-43.
-
(1998)
Phacoemulsification, Laser Cataract Surgery and Foldable IOLs
, pp. 139-143
-
-
Argarwal, A.1
Argarwal, S.2
Argarwal, A.3
-
5
-
-
34250318211
-
Feasibility of bimanual microincision phacoemulsification in hard cataracts
-
Assaf A, El-Moatassem Kotb AM. Feasibility of bimanual microincision phacoemulsification in hard cataracts. Eye 2007; 21: 807-11.
-
(2007)
Eye
, vol.21
, pp. 807-811
-
-
Assaf, A.1
El-Moatassem Kotb, A.M.2
-
6
-
-
1242296887
-
Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataract
-
Olson RJ. Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataract. J Cataract Refract Surg 2004; 30: 168-72.
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 168-172
-
-
Olson, R.J.1
-
7
-
-
0036274219
-
Bimanual phacoemulsification through 2 stab incisions. A wound-temperature study
-
Soscia W, Howard JG, Olson RJ. Bimanual phacoemulsification through 2 stab incisions. A wound-temperature study. J Cataract Refract Surg 2002; 28: 1039-43.
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1039-1043
-
-
Soscia, W.1
Howard, J.G.2
Olson, R.J.3
-
8
-
-
0036271758
-
Microphacoemulsification with WhiteStarA wound-temperature study
-
Soscia W, Howard JG, Olson RJ, Microphacoemulsification with WhiteStarA wound-temperature study. J Cataract Refract Surg 2002; 28: 1044-6.
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1044-1046
-
-
Soscia, W.1
Howard, J.G.2
Olson, R.J.3
-
9
-
-
2342499805
-
Legacy AdvanTec and Sovereign WhiteStar: A wound temperature study
-
Olson RJ, Jin Y, Gus K et al. Legacy AdvanTec and Sovereign WhiteStar: A wound temperature study. J Cataract Refract Surg 2004; 30: 1109-13.
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 1109-1113
-
-
Olson, R.J.1
Jin, Y.2
Gus, K.3
-
10
-
-
85047172435
-
Temperature during bimanual phacoemulsification
-
Mackool RJ. Temperature during bimanual phacoemulsification. J Cataract Refract Surg 2004; 30: 732.
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 732
-
-
Mackool, R.J.1
-
11
-
-
0025045886
-
Air bubble endothelial damage during phacoemulsification in human eye bank eyes: The protective effects of Healon and Viscoat
-
Craig MT, Olson RJ, Mamalis N et al. Air bubble endothelial damage during phacoemulsification in human eye bank eyes: The protective effects of Healon and Viscoat. J Cataract Refract Surg 1990; 16: 597-602.
-
(1990)
J Cataract Refract Surg
, vol.16
, pp. 597-602
-
-
Craig, M.T.1
Olson, R.J.2
Mamalis, N.3
-
12
-
-
0026768753
-
Oxiradical-dependent photoemission induced by a phacoemulsification probe
-
Shimmura S, Tsubota K, Oguchi Y et al. Oxiradical-dependent photoemission induced by a phacoemulsification probe. Invest Ophthalmol Vis Sci 1992; 33: 2904-7.
-
(1992)
Invest Ophthalmol Vis Sci
, vol.33
, pp. 2904-2907
-
-
Shimmura, S.1
Tsubota, K.2
Oguchi, Y.3
|