메뉴 건너뛰기




Volumn 17, Issue 1, 2006, Pages 62-67

Update on bimanual microincisional cataract surgery

Author keywords

Bimanual; Cataract surgery; Micro incision; Microphacoemulsification; Phacoemulsification; Rollable intraocular lens

Indexed keywords

BIMANUAL MICROINCISIONAL CATARACT SURGERY; CATARACT EXTRACTION; CORNEA; ECHOGRAPHY; HUMAN; INCISION; LENS IMPLANT; PHACOEMULSIFICATION; PRIORITY JOURNAL; REVIEW; SAFETY; SURGICAL TECHNIQUE; TECHNOLOGY; TREATMENT OUTCOME;

EID: 29844445212     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (65)

References (25)
  • 1
    • 0037615199 scopus 로고
    • Routine phacoemulsification through a one-millimeter nonsutured incision
    • Shearing SP, Relyea RL, Louiza A, et al. Routine phacoemulsification through a one-millimeter nonsutured incision. Cataract 1985; 2:6-11.
    • (1985) Cataract , vol.2 , pp. 6-11
    • Shearing, S.P.1    Relyea, R.L.2    Louiza, A.3
  • 2
    • 0017793932 scopus 로고
    • Ultrasonic fragmentation for cataract extraction and cataract complications
    • Girard LJ. Ultrasonic fragmentation for cataract extraction and cataract complications. Adv Ophthalmol 1978; 37:127-135.
    • (1978) Adv Ophthalmol , vol.37 , pp. 127-135
    • Girard, L.J.1
  • 4
    • 15044356509 scopus 로고    scopus 로고
    • New phacoemulsification technology
    • Hoffman RS, Fine IH, Packer M. New phacoemulsification technology. Curr Opin Ophthalmol 2005; 16:38-43. Excellent review of the major phacoemulsification platforms highlighting advances in ultrasound power management and fluidic control.
    • (2005) Curr Opin Ophthalmol , vol.16 , pp. 38-43
    • Hoffman, R.S.1    Fine, I.H.2    Packer, M.3
  • 5
    • 15044357195 scopus 로고    scopus 로고
    • Bimanual microincisional phacoemulsification: The future of cataract surgery?
    • Paul T, Braga-Mele R. Bimanual microincisional phacoemulsification: the future of cataract surgery? Curr Opin Ophthalmol 2005; 16:2-7. Comprehensive review of bimanual MICS technology and techniques.
    • (2005) Curr Opin Ophthalmol , vol.16 , pp. 2-7
    • Paul, T.1    Braga-Mele, R.2
  • 6
    • 23944460854 scopus 로고    scopus 로고
    • Visual outcome of microincision cataract surgery with implantation of an Acri.Smart lens
    • Alio JL, Rodriquez-Prats JL, Vianello A, et al. Visual outcome of microincision cataract surgery with implantation of an Acri.Smart lens. J Cataract Refract Surg 2005; 31:1549-1556. Clinical outcomes of bimanual MICS combined with implantation of a microincision intraocular.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1549-1556
    • Alio, J.L.1    Rodriquez-Prats, J.L.2    Vianello, A.3
  • 7
    • 0036732787 scopus 로고    scopus 로고
    • Phakonit: Cataract removal through a sub-1.0 mm incision and implantation of the ThinOptX reliable intraocular lens
    • Pandey SK., Werner L, Agarwal A, et al. Phakonit: cataract removal through a sub-1.0 mm incision and implantation of the ThinOptX reliable intraocular lens. J Cataract Refract Surg 2002; 28:1710-1712.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1710-1712
    • Pandey, S.K.1    Werner, L.2    Agarwal, A.3
  • 8
    • 1842581519 scopus 로고    scopus 로고
    • Early visual results with the reliable ThinOptX intraocular lens
    • Dogru M, Honda R, Omoto M1 ef Bl. Early visual results with the reliable ThinOptX intraocular lens. J Cataract Refract Surg 2004; 30:558-565.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 558-565
    • Dogru, M.1    Honda, R.2    Omoto, M.3
  • 9
    • 23944443051 scopus 로고    scopus 로고
    • Retinal image quality after microincision intraocular lens implantation
    • Alió JL, Schimchak P, Montes-Mico R, et al. Retinal image quality after microincision intraocular lens implantation. J Cataract Refract Surg 2005; 31: 1557-1560.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1557-1560
    • Alió, J.L.1    Schimchak, P.2    Montes-Mico, R.3
  • 10
    • 0036274219 scopus 로고    scopus 로고
    • Bimanual phacoemulsification through 2 stab incisions: A wound-temperature study
    • Soscia W, Howard JG, Olson RJ. Bimanual phacoemulsification through 2 stab incisions: a wound-temperature study. J Cataract Refract Surg 2002; 28:1039-1043.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1039-1043
    • Soscia, W.1    Howard, J.G.2    Olson, R.J.3
  • 11
    • 0036271758 scopus 로고    scopus 로고
    • Microphacoemulsification with WhiteStar: A wound-temperature study
    • Soscia W, Howard JG, Olson RJ. Microphacoemulsification with WhiteStar: a wound-temperature study. J Cataract Refract Surg 2002; 28:1044-1046.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1044-1046
    • Soscia, W.1    Howard, J.G.2    Olson, R.J.3
  • 12
    • 0037974455 scopus 로고    scopus 로고
    • Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision
    • Donnenfeld ED, Olson RJ, Solomon R, et al. Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision. J Cataract Refract Surg 2003; 29:1097-1100.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1097-1100
    • Donnenfeld, E.D.1    Olson, R.J.2    Solomon, R.3
  • 13
    • 0348010438 scopus 로고    scopus 로고
    • Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system
    • Braga-Mele R, Liu E. Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system. J Cataract Refract Surg 2003; 29:2199-2203.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2199-2203
    • Braga-Mele, R.1    Liu, E.2
  • 14
    • 1342347697 scopus 로고    scopus 로고
    • AquaLase: A new technology for cataract extraction
    • Mackool RJ, Brint SF. AquaLase: a new technology for cataract extraction. Curr Opin Ophthalmol 2004; 15:40-43.
    • (2004) Curr Opin Ophthalmol , vol.15 , pp. 40-43
    • Mackool, R.J.1    Brint, S.F.2
  • 15
    • 2342499805 scopus 로고    scopus 로고
    • Legacy AdvanTec and Sovereign WhiteStar: A wound temperature study
    • Olson RJ, Jin Y, Kefalopoulos G, et al. Legacy AdvanTec and Sovereign WhiteStar: A wound temperature study. J Cataract Refract Surg 2004; 30: 1109-1113.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1109-1113
    • Olson, R.J.1    Jin, Y.2    Kefalopoulos, G.3
  • 16
    • 23944485218 scopus 로고    scopus 로고
    • In-air thermal imaging comparison of Legacy AdvanTec, Millennium, an Sovereign WhiteStar phacoemulsification systems
    • Olson MD, Miller KM. In-air thermal imaging comparison of Legacy AdvanTec, Millennium, an Sovereign WhiteStar phacoemulsification systems. J Cataract Refract Surg 2005; 31:1640-1647.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1640-1647
    • Olson, M.D.1    Miller, K.M.2
  • 17
    • 0037636289 scopus 로고    scopus 로고
    • Ultrasmall-incision bimanual phacoemulsification and AcrySof SA30AL implantation through a 2.2-mm incision
    • Tsueoka H, Hayama A, Takahama M. Ultrasmall-incision bimanual phacoemulsification and AcrySof SA30AL implantation through a 2.2-mm incision. J Cataract Refract Surg 2003; 29:1070-1076.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1070-1076
    • Tsueoka, H.1    Hayama, A.2    Takahama, M.3
  • 18
    • 29844454342 scopus 로고    scopus 로고
    • Coaxial and bimanual phacoemulsification; considerations in patient and technique selection
    • Rose AD. Coaxial and bimanual phacoemulsification; considerations in patient and technique selection. Tech Ophthalmol 2005; 3:63-70. Detailed summary of one surgeon's technique and experience with bimanual phacoemulsification, including a wealth of practical information
    • (2005) Tech Ophthalmol , vol.3 , pp. 63-70
    • Rose, A.D.1
  • 19
    • 1842424470 scopus 로고    scopus 로고
    • Optimizing refractive lens exchange with bimanual microincision phacoemulsification
    • Fine IH, Hoffman RS, Packer M. Optimizing refractive lens exchange with bimanual microincision phacoemulsification. J Cataract Refract Surg 2004; 30:550-554.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 550-554
    • Fine, I.H.1    Hoffman, R.S.2    Packer, M.3
  • 20
    • 15044343233 scopus 로고    scopus 로고
    • 400 mmHg High-vacuum bimanual phaco attainable with the Staar Cruise control device
    • Chang DF. 400 mmHg High-vacuum bimanual phaco attainable with the Staar Cruise control device. J Cataract Refract Surg 2004; 30:932-933.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 932-933
    • Chang, D.F.1
  • 21
    • 20544470514 scopus 로고    scopus 로고
    • Clear corneal paracentesis: A case of chronic wound leakage in a patient having bimanual phacoemulsification
    • Stratas BA. Clear corneal paracentesis: A case of chronic wound leakage in a patient having bimanual phacoemulsification. J Cataract Refract Surg 2005; 31:1075.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1075
    • Stratas, B.A.1
  • 22
    • 0036144095 scopus 로고    scopus 로고
    • Ultrasonic phacoemulsification using a 1.4 mm incision: Clinical results
    • Tsuneoka H, Shiba T, Takahama M. Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results. J Cataract Refract Surg 2002; 28:81-86.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 81-86
    • Tsuneoka, H.1    Shiba, T.2    Takahama, M.3
  • 23
    • 0034753476 scopus 로고    scopus 로고
    • Phakonit: Phacoemulsification through a 0.9 mm corneal incision
    • Agarwal A, Agarwal A, Agarwal S, et al. Phakonit: phacoemulsification through a 0.9 mm corneal incision. J Cataract Refract Surg 2001; 27: 1548-1552.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1548-1552
    • Agarwal, A.1    Agarwal, A.2    Agarwal, S.3
  • 24
    • 1242296887 scopus 로고    scopus 로고
    • Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataract
    • Olson RJ. Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar Technology in eyes with dense cataract. J Cataract Refract Surg 2004; 30:168-172.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 168-172
    • Olson, R.J.1
  • 25
    • 27644453444 scopus 로고    scopus 로고
    • Outcomes of microincision cataract surgery versus coaxial phacoemulsification
    • in press
    • Alió JL, Rodriguez-Prats JL, Galal A, et al. Outcomes of microincision cataract surgery versus coaxial phacoemulsification. Ophthalmology 2005 in press. Comprehensive, head-to-head comparison of bimanual MICS and conventional SICS.
    • (2005) Ophthalmology
    • Alió, J.L.1    Rodriguez-Prats, J.L.2    Galal, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.