메뉴 건너뛰기




Volumn 23, Issue 1, 2008, Pages 17-21

Incident-simulating device with wireless control for extracorporeal circulation crisis management drills

Author keywords

Crisis management drill; Extracorporeal circulation; Safety; Simulation device; Wireless

Indexed keywords

ARTERY OCCLUSION; ARTICLE; ELECTRIC BATTERY; ELECTRONIC SENSOR; ELECTRONICS; EXTRACORPOREAL CIRCULATION; PERFUSION PRESSURE; PRIORITY JOURNAL; SIMULATION; TRANSDUCER; VEIN BLOOD FLOW; VEIN OCCLUSION;

EID: 50649086565     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/0267659108093874     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 0242720730 scopus 로고    scopus 로고
    • Departmental use of perfusion crisis management drills: 2002 survey results
    • Ginther, R, Fillingham, R, Searles, B, Darling, E. Departmental use of perfusion crisis management drills: 2002 survey results. Perfusion 2003; 18(5): 299-302.
    • (2003) Perfusion , vol.18 , Issue.5 , pp. 299-302
    • Ginther, R.1    Fillingham, R.2    Searles, B.3    Darling, E.4
  • 2
    • 28844463441 scopus 로고    scopus 로고
    • Simulation devices in cardiothoracic and vascular anesthesia
    • Eason, MP. Simulation devices in cardiothoracic and vascular anesthesia. Semin Cardiothorac Vasc Anesth 2005; 9(4): 309-323.
    • (2005) Semin Cardiothorac Vasc Anesth , vol.9 , Issue.4 , pp. 309-323
    • Eason, M.P.1
  • 3
    • 40949106933 scopus 로고    scopus 로고
    • Orpheus cardiopulmonary bypass simulation system
    • Morris, RW, Pybus, DA. "Orpheus" cardiopulmonary bypass simulation system. J Extra Corpor Technol 2007; 39(4): 228-233.
    • (2007) J Extra Corpor Technol , vol.39 , Issue.4 , pp. 228-233
    • Morris, R.W.1    Pybus, D.A.2
  • 4
    • 50649089631 scopus 로고    scopus 로고
    • Accessed on April 14, 2008
    • http://jasect.umin.ac.jp/. [Accessed on April 14, 2008].
  • 5
    • 0034713363 scopus 로고    scopus 로고
    • Wireless capsule endoscopy
    • Iddan, G, Meron, G, Glukhovsky, A, Swain, P. Wireless capsule endoscopy. Nature 2000; 405(6785): 417-418.
    • (2000) Nature , vol.405 , Issue.6785 , pp. 417-418
    • Iddan, G.1    Meron, G.2    Glukhovsky, A.3    Swain, P.4
  • 8
    • 33144460244 scopus 로고    scopus 로고
    • Perfusion education and training in Europe
    • Merkle, F. Perfusion education and training in Europe. Perfusion 2006; 21(1): 3-12.
    • (2006) Perfusion , vol.21 , Issue.1 , pp. 3-12
    • Merkle, F.1
  • 9
    • 78651040356 scopus 로고
    • An improved mechanical heart and lung apparatus; its use during open cardiotomy in experimental animals
    • Miller, BJ, Gibbon, JH, Fineberg, C. An improved mechanical heart and lung apparatus; its use during open cardiotomy in experimental animals. Med Clin North Am 1953; 37: 1603-1624.
    • (1953) Med Clin North Am , vol.37 , pp. 1603-1624
    • Miller, B.J.1    Gibbon, J.H.2    Fineberg, C.3
  • 10
    • 50649106236 scopus 로고    scopus 로고
    • A problem in extended operating room design turns out due to power failure during surgery: A case report
    • Kawatani, Y, Iwahana, M, Sugahara, S. A problem in extended operating room design turns out due to power failure during surgery: a case report. J Jpn Assoc Operat Room Tech 2003; 24(1): 63-66.
    • (2003) J Jpn Assoc Operat Room Tech , vol.24 , Issue.1 , pp. 63-66
    • Kawatani, Y.1    Iwahana, M.2    Sugahara, S.3
  • 11
    • 50649086856 scopus 로고    scopus 로고
    • Accessed on April 14, 2008
    • http://www.jsao.org/member/index3.htm. [Accessed on April 14, 2008].
  • 12
    • 50649113305 scopus 로고    scopus 로고
    • Trouble simulation course for extracorporeal circulation: Experiences from wet lab
    • Tomizawa, Y. Trouble simulation course for extracorporeal circulation: experiences from wet lab. Jpn J Artif Organs 2006; 35(1): 233-226.
    • (2006) Jpn J Artif Organs , vol.35 , Issue.1 , pp. 233-226
    • Tomizawa, Y.1
  • 13
    • 38449106242 scopus 로고    scopus 로고
    • Safety measures of extracorporeal circulation by heart surgeons and perfusionists
    • Tomizawa, Y, Momose, N, Matayoshi, T, Yozu, R, Takamoto, S. Safety measures of extracorporeal circulation by heart surgeons and perfusionists. Kyobu Geka 2007; 60(12): 1055-1059.
    • (2007) Kyobu Geka , vol.60 , Issue.12 , pp. 1055-1059
    • Tomizawa, Y.1    Momose, N.2    Matayoshi, T.3    Yozu, R.4    Takamoto, S.5
  • 14
    • 36949029556 scopus 로고    scopus 로고
    • Development of an educational simulator system, ECCSIM-Lite, for the acquisition of basic perfusion techniques and evaluation
    • Ninomiya, S, Tokumine, A, Yasuda, T, Tomizawa, Y. Development of an educational simulator system, ECCSIM-Lite, for the acquisition of basic perfusion techniques and evaluation. J Artif Organs 2007; 10(4): 201-205.
    • (2007) J Artif Organs , vol.10 , Issue.4 , pp. 201-205
    • Ninomiya, S.1    Tokumine, A.2    Yasuda, T.3    Tomizawa, Y.4
  • 15
    • 34447311422 scopus 로고    scopus 로고
    • Certified perfusionists in Japan
    • Tomizawa, Y, Momose, N. Certified perfusionists in Japan. J Artif Organs 2007; 10(2): 122-123.
    • (2007) J Artif Organs , vol.10 , Issue.2 , pp. 122-123
    • Tomizawa, Y.1    Momose, N.2
  • 16
    • 23844484819 scopus 로고    scopus 로고
    • Perfusion safety in Europe: Managing risks, learning from mistakes
    • Graves, K. Perfusion safety in Europe: managing risks, learning from mistakes. Perfusion 2005; 20(4): 209-215.
    • (2005) Perfusion , vol.20 , Issue.4 , pp. 209-215
    • Graves, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.