메뉴 건너뛰기




Volumn 112, Issue 4, 2009, Pages 1065-1071

Analysis of non-fat soybean powder for the mass fractions of three elements: Copper and zinc by isotope dilution ICP-MS and calcium by ICP-AES

Author keywords

Bracketing technique; Calcium; CCQM; Copper; ICP AES; ICP MS; Isotope dilution mass spectrometry; Soybean; Zinc

Indexed keywords

CALCIUM; COPPER; ZINC;

EID: 50249105251     PISSN: 03088146     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.foodchem.2008.06.067     Document Type: Article
Times cited : (29)

References (21)
  • 1
    • 27144511528 scopus 로고    scopus 로고
    • CCQM-K24 key comparison. Cadmium amount content in rice
    • Aregbe Y., and Taylor P. CCQM-K24 key comparison. Cadmium amount content in rice. Metrologia 40 (2003) 08001
    • (2003) Metrologia , vol.40 , pp. 08001
    • Aregbe, Y.1    Taylor, P.2
  • 2
    • 84872892219 scopus 로고    scopus 로고
    • BS 700-1:1982. Graduated pipettes. Specification for general requirements. UK: British Standards Institution.
    • BS 700-1:1982. Graduated pipettes. Specification for general requirements. UK: British Standards Institution.
  • 3
    • 84872887095 scopus 로고    scopus 로고
    • BS EN ISO 1042:2000. Laboratory glassware. One-mark volumetric flasks. UK: British Standards Institution.
    • BS EN ISO 1042:2000. Laboratory glassware. One-mark volumetric flasks. UK: British Standards Institution.
  • 5
    • 84872882129 scopus 로고    scopus 로고
    • Ellison, S. L. R., Rosslein, M., & Williams, A. (2000). Quantifying uncertainty in analytical measurement. EURACHEM/CITAC.
    • Ellison, S. L. R., Rosslein, M., & Williams, A. (2000). Quantifying uncertainty in analytical measurement. EURACHEM/CITAC.
  • 6
    • 0029144207 scopus 로고
    • Determination of fission products and actinides by inductively coupled plasma-mass spectrometry using isotope dilution analysis: A study of random and systematic errors
    • García Alonso J.I. Determination of fission products and actinides by inductively coupled plasma-mass spectrometry using isotope dilution analysis: A study of random and systematic errors. Analytica Chimica Acta 312 (1995) 57-78
    • (1995) Analytica Chimica Acta , vol.312 , pp. 57-78
    • García Alonso, J.I.1
  • 7
    • 0037349084 scopus 로고    scopus 로고
    • Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis
    • Grotti M., Magi E., and Leardi R. Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis. Journal of Analytical Atomic Spectrometry 18 (2003) 274-281
    • (2003) Journal of Analytical Atomic Spectrometry , vol.18 , pp. 274-281
    • Grotti, M.1    Magi, E.2    Leardi, R.3
  • 8
    • 0000117636 scopus 로고
    • Reduction of systematic errors in quantitative analysis by isotope dilution mass spectrometry (IDMS): an iterative method
    • Henrion A. Reduction of systematic errors in quantitative analysis by isotope dilution mass spectrometry (IDMS): an iterative method. Fresenius' Journal of Analytical Chemistry 350 (1994) 657-658
    • (1994) Fresenius' Journal of Analytical Chemistry , vol.350 , pp. 657-658
    • Henrion, A.1
  • 9
    • 0030682934 scopus 로고    scopus 로고
    • The Comité Consultatif pour la Quantité de Matière: a brief review of its origin and present activities
    • Kaarls R., and Quinn T.J. The Comité Consultatif pour la Quantité de Matière: a brief review of its origin and present activities. Metrologia 34 (1997) 1-5
    • (1997) Metrologia , vol.34 , pp. 1-5
    • Kaarls, R.1    Quinn, T.J.2
  • 10
    • 37049080642 scopus 로고
    • Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique
    • Kragten J. Calculating standard deviations and confidence intervals with a universally applicable spreadsheet technique. Analyst 10 (1994) 2161-2165
    • (1994) Analyst , vol.10 , pp. 2161-2165
    • Kragten, J.1
  • 11
    • 84872882573 scopus 로고    scopus 로고
    • Ma, L., Wang, J., Lu, X., Wei, C., Wu, B., Lu, H., & Guan, N. (2007). Report of the CCQM-P64 & APMP.QM-P07 Cu, Zn, Fe and Ca in non-fat soybean powder (final report). China: National Institute of Metrology People's Republic of China and National Research Center for Certified Reference Materials.
    • Ma, L., Wang, J., Lu, X., Wei, C., Wu, B., Lu, H., & Guan, N. (2007). Report of the CCQM-P64 & APMP.QM-P07 Cu, Zn, Fe and Ca in non-fat soybean powder (final report). China: National Institute of Metrology People's Republic of China and National Research Center for Certified Reference Materials.
  • 12
    • 0000151143 scopus 로고    scopus 로고
    • A table of polyatomic interferences in ICP-MS
    • May T.W., and Wiedmeyer R.H. A table of polyatomic interferences in ICP-MS. Atomic Spectroscopy 19 (1998) 150-155
    • (1998) Atomic Spectroscopy , vol.19 , pp. 150-155
    • May, T.W.1    Wiedmeyer, R.H.2
  • 13
    • 0032073794 scopus 로고    scopus 로고
    • Revisitation of the matrix effects in inductively coupled plasma atomic emission spectrometry: the key role of the spray chamber
    • Mermet J.M. Revisitation of the matrix effects in inductively coupled plasma atomic emission spectrometry: the key role of the spray chamber. Journal of Analytical Atomic Spectrometry 13 (1998) 419-422
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 419-422
    • Mermet, J.M.1
  • 14
    • 0001692416 scopus 로고    scopus 로고
    • ICP-MS applied to isotope abundance ratio measurements: performance study and development of a method for combining uncertainty contributions from measurement correction factors
    • Holland G., and Tanner S.D. (Eds), The Royal Society of Chemistry, London
    • Quétel C.R., Prohaska T., Nelms S.M., Diemer J., and Taylor P.D.P. ICP-MS applied to isotope abundance ratio measurements: performance study and development of a method for combining uncertainty contributions from measurement correction factors. In: Holland G., and Tanner S.D. (Eds). Plasma source mass spectrometry: the new millennium (2001), The Royal Society of Chemistry, London 257-269
    • (2001) Plasma source mass spectrometry: the new millennium , pp. 257-269
    • Quétel, C.R.1    Prohaska, T.2    Nelms, S.M.3    Diemer, J.4    Taylor, P.D.P.5
  • 17
    • 84872885844 scopus 로고    scopus 로고
    • USEPA. (1996). Method 6010B Revision 2 Inductively coupled plasma-atomic emission spectrometry. Washington: US Environmental Protection Agency.
    • USEPA. (1996). Method 6010B Revision 2 Inductively coupled plasma-atomic emission spectrometry. Washington: US Environmental Protection Agency.
  • 18
    • 0004895380 scopus 로고    scopus 로고
    • Atomic weights of the elements 1997
    • Vocke Jr. R.D. Atomic weights of the elements 1997. Pure and Applied Chemistry 71 (1997) 1593-1607
    • (1997) Pure and Applied Chemistry , vol.71 , pp. 1593-1607
    • Vocke Jr., R.D.1
  • 19
    • 0030711944 scopus 로고    scopus 로고
    • Isotope dilution using inductively coupled plasma-mass spectrometry (ICP-MS) as a primary method
    • Watters Jr. R.L., Eberhardt K.R., Beary E.S., and Fassett J.D. Isotope dilution using inductively coupled plasma-mass spectrometry (ICP-MS) as a primary method. Metrologia 34 (1997) 87-96
    • (1997) Metrologia , vol.34 , pp. 87-96
    • Watters Jr., R.L.1    Eberhardt, K.R.2    Beary, E.S.3    Fassett, J.D.4
  • 20
    • 0035919259 scopus 로고    scopus 로고
    • Orthodox uncertainty budgeting for high accuracy measurements by isotope dilution inductively coupled plasma-mass spectrometry
    • Wolff Briche C.S.J., Harrington C., Catterick T., and Fairman B. Orthodox uncertainty budgeting for high accuracy measurements by isotope dilution inductively coupled plasma-mass spectrometry. Analytica Chimica Acta 437 (2001) 1-10
    • (2001) Analytica Chimica Acta , vol.437 , pp. 1-10
    • Wolff Briche, C.S.J.1    Harrington, C.2    Catterick, T.3    Fairman, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.