메뉴 건너뛰기




Volumn , Issue , 2007, Pages 355-358

Hydrolytic microneedles as transdermal drug delivery system

Author keywords

Bio degradable; Drug delivery system; Hydrolytic; Microneedle

Indexed keywords

ACTUATORS; CHEMOTHERAPY; DRUG DELIVERY; DRUG DOSAGE; MICROSYSTEMS; NEEDLES; OFFSHORE OIL WELL PRODUCTION; SENSORS; SKIN; TRANSDUCERS;

EID: 50049135959     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2007.4300141     Document Type: Conference Paper
Times cited : (8)

References (9)
  • 1
    • 0034578084 scopus 로고    scopus 로고
    • Microfabricated Microneedles for Gene and Drug Delivery
    • D. V. McAllister, M. G. Allen, M. R. Prausnitz, "Microfabricated Microneedles for Gene and Drug Delivery", Ann. Biomed. Eng., vol.2, pp.289-313, 2000.
    • (2000) Ann. Biomed. Eng , vol.2 , pp. 289-313
    • McAllister, D.V.1    Allen, M.G.2    Prausnitz, M.R.3
  • 2
    • 0344270926 scopus 로고    scopus 로고
    • Microfabricated Needles for Transdermal Delivery of Macromolecules and Nanoparticles: Fabrication Methods and Transport Studies
    • D. V. McAllister, P. M. Wang, S. P. Davis, J. -H. Park, P. J. Canatella, M. G. Allen, M. R. Prausnitz, "Microfabricated Needles for Transdermal Delivery of Macromolecules and Nanoparticles: Fabrication Methods and Transport Studies", Proc. Natl. Acad. Sci. USA, vol.100, pp.13755-13760, 2003.
    • (2003) Proc. Natl. Acad. Sci. USA , vol.100 , pp. 13755-13760
    • McAllister, D.V.1    Wang, P.M.2    Davis, S.P.3    Park, J.-H.4    Canatella, P.J.5    Allen, M.G.6    Prausnitz, M.R.7
  • 4
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable Plymer Microneedles: Fabrication, Machanics, and Transdermal Drug Delivery
    • J. -H. Park, M. G. Allen, M. R. Prausnitz, "Biodegradable Plymer Microneedles: Fabrication, Machanics, and Transdermal Drug Delivery", J. Control. Release, vol.104, pp.51-66, 2005.
    • (2005) J. Control. Release , vol.104 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 5
    • 33646709695 scopus 로고    scopus 로고
    • Mechanism of Fluid Infusion during Microneedle Insertion and Retraction
    • W. Martanto, J. S. Moore, T. Couse, M. R. Prausnitz, "Mechanism of Fluid Infusion during Microneedle Insertion and Retraction", J. Control. Release, vol.112 (2006) pp.357-361.
    • (2006) J. Control. Release , vol.112 , pp. 357-361
    • Martanto, W.1    Moore, J.S.2    Couse, T.3    Prausnitz, M.R.4
  • 7
    • 20444373374 scopus 로고    scopus 로고
    • Preparation and Characterization of Biodegradable Nanoparticles Entrapping Immunodominant Peptide Conjugated with PEG for Oral Tolerance Induction
    • W. -K. Lee, J. -Y. Park, S. Jung, C. W. Yang, W. -U. Kim, H. -Y. Kim, J. -H. Park, J. -S. Park, "Preparation and Characterization of Biodegradable Nanoparticles Entrapping Immunodominant Peptide Conjugated with PEG for Oral Tolerance Induction", J. Control. Release, vol.105, pp.77-88, 2005.
    • (2005) J. Control. Release , vol.105 , pp. 77-88
    • Lee, W.-K.1    Park, J.-Y.2    Jung, S.3    Yang, C.W.4    Kim, W.-U.5    Kim, H.-Y.6    Park, J.-H.7    Park, J.-S.8
  • 9
    • 50049088288 scopus 로고    scopus 로고
    • Effect of Penetration Enhancers on the Permeation of Drugs across a Three-Dimensional Cultured Human Skin Model: Comparison with the Effects Using Excised Hairless Rat Skin
    • T. Watanabe, T. Hasegawa, H. Tskahashi, T. Ishibashi, and K. Sugibayashi, "Effect of Penetration Enhancers on the Permeation of Drugs across a Three-Dimensional Cultured Human Skin Model: Comparison with the Effects Using Excised Hairless Rat Skin," Altern. Animal Test. Experiment., vol.8, pp.15-22, 2001.
    • (2001) Altern. Animal Test. Experiment , vol.8 , pp. 15-22
    • Watanabe, T.1    Hasegawa, T.2    Tskahashi, H.3    Ishibashi, T.4    Sugibayashi, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.