메뉴 건너뛰기




Volumn , Issue , 2007, Pages 690-692

Studies on cantilever based triglyceride biosensor

Author keywords

Biosensor; Microcantilever; Resonance frequency; Triglyceride; Vibrometer

Indexed keywords

BIOSENSOR; CALIBRATION PLOT; DOPPLER; DYNAMIC PROPERTIES; ENZYMATIC HYDROLYSIS; MICROCANTILEVER; MICROMACHINED; MICROMOLAR LEVELS; RESONANCE FREQUENCIES; RESONANCE FREQUENCY; TRIGLYCERIDE; VIBROMETER; VIBROMETRY;

EID: 49749118852     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IWPSD.2007.4472613     Document Type: Conference Paper
Times cited : (4)

References (8)
  • 2
    • 0035133605 scopus 로고    scopus 로고
    • Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor
    • J. Tamayo, A.D.L Humphris, A.M. Malloy, M.J. Miles, "Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor", Ultramicroscopy, vol. 86, 2001, 167-173
    • (2001) Ultramicroscopy , vol.86 , pp. 167-173
    • Tamayo, J.1    Humphris, A.D.L.2    Malloy, A.M.3    Miles, M.J.4
  • 3
    • 0347758352 scopus 로고    scopus 로고
    • Glucose Biosensor Based on the Microcantilever
    • J. Pei, F. Tian, T. Thundat, "Glucose Biosensor Based on the Microcantilever", Analytical Chemistry, vol.76, 2004, pp. 292-297
    • (2004) Analytical Chemistry , vol.76 , pp. 292-297
    • Pei, J.1    Tian, F.2    Thundat, T.3
  • 6
    • 37549002897 scopus 로고    scopus 로고
    • Parameter extraction from simple electrical measurements on surface micromachined cantilevers
    • to be published
    • S. Bhat, E. Bhattacharya, "Parameter extraction from simple electrical measurements on surface micromachined cantilevers", Journal of Micro/Nanolithography, MEMS and MOEMS, 2007, to be published
    • (2007) Journal of Micro/Nanolithography, MEMS and MOEMS
    • Bhat, S.1    Bhattacharya, E.2
  • 7
    • 23044511502 scopus 로고    scopus 로고
    • Detection of pathogen Escherichia coli O157:H7 using self- excited PZT-glass microcantilevers
    • G.A.Campbell, R.Mutharasan, "Detection of pathogen Escherichia coli O157:H7 using self- excited PZT-glass microcantilevers", Biosensors and Bioelectronics, vol. 21,2005, pp.462-473.
    • (2005) Biosensors and Bioelectronics , vol.21 , pp. 462-473
    • Campbell, G.A.1    Mutharasan, R.2
  • 8
    • 33845725243 scopus 로고    scopus 로고
    • Resonant frequencies of a rectangular cantilever beam immersed in a fluid
    • C. A. Van Eysden and J. E. Sader, "Resonant frequencies of a rectangular cantilever beam immersed in a fluid", Journal of Applied physics, vol.100, 2006, pp.114916
    • (2006) Journal of Applied physics , vol.100 , pp. 114916
    • Van Eysden, C.A.1    Sader, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.