Volumn 36, Issue 9, 2008, Pages 1594-1603

A DSP based multi-frequency 3D electrical impedance tomography system

Author keywords

Electrical impedance tomography; Hardware design; Multi frequency EIT

Indexed keywords

ACOUSTIC INTENSITY; DEMODULATION; DIAGNOSTIC RADIOGRAPHY; DIGITAL SIGNAL PROCESSORS; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; GAIN CONTROL; IMAGE PROCESSING; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; MACHINE DESIGN; MEDICAL IMAGING; OPTIMAL CONTROL SYSTEMS; PERMITTIVITY; REPAIR; RESTORATION; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO; TANKS (CONTAINERS); THERMOGRAPHY (TEMPERATURE MEASUREMENT); THREE DIMENSIONAL; TOMOGRAPHY;

EID: 49149113877     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-008-9537-5     Document Type: Article
Times cited : (30)

References (39)
  • 1
    • 0021500331 scopus 로고
    • Applied potential tomography
    • doi: 10.1088/0022-3735/17/9/002
    • Barber D. C., Brown B. H. 1984 Applied potential tomography. J. Phys. E Sci. Instrum. 17, 723-733 doi: 10.1088/0022-3735/17/9/002
    • (1984) J. Phys. e Sci. Instrum. , vol.17 , pp. 723-733
    • Barber, D.C.1    Brown, B.H.2
  • 2
    • 0033999537 scopus 로고    scopus 로고
    • A comparison of modified Howland circuits as current generators with current mirror type circuits
    • doi: 10.1088/0967-3334/21/1/301
    • Bertemes-Filho P., Brown B. H., Wilson A. J. 2000 A comparison of modified Howland circuits as current generators with current mirror type circuits. Physiol. Meas. 21, 1-6 doi: 10.1088/0967-3334/21/1/301
    • (2000) Physiol. Meas. , vol.21 , pp. 1-6
    • Bertemes-Filho, P.1    Brown, B.H.2    Wilson, A.J.3
  • 3
    • 0030250203 scopus 로고    scopus 로고
    • Clinical application of characteristic frequency measurements: Preliminary in vivo study
    • Blad B. 1996 Clinical application of characteristic frequency measurements: preliminary in vivo study. Med. Biol. Eng. Comput. 34, 362-365 doi: 10.1007/BF02520006
    • (1996) Med. Biol. Eng. Comput. , vol.34 , pp. 362-365
    • Blad, B.1
  • 4
    • 0029801362 scopus 로고    scopus 로고
    • Impedance spectra of tumor tissue in comparison with normal tissue: A possible clinical application for electrical impedance tomography
    • doi: 10.1088/0967-3334/17/4A/015
    • Blad B., Baldetorp B. 1996 Impedance spectra of tumor tissue in comparison with normal tissue: a possible clinical application for electrical impedance tomography. Physiol. Meas. 17, A105-A115 doi: 10.1088/0967-3334/17/4A/ 015
    • (1996) Physiol. Meas. , vol.17
    • Blad, B.1    Baldetorp, B.2
  • 5
    • 0029819404 scopus 로고    scopus 로고
    • Current approaches to analogue instrumentation design in electrical impedance tomography
    • doi: 10.1088/0967-3334/17/4/001
    • Boone K. G., Holder D. S. 1996 Current approaches to analogue instrumentation design in electrical impedance tomography. Physiol. Meas. 17, 229-247 doi: 10.1088/0967-3334/17/4/001
    • (1996) Physiol. Meas. , vol.17 , pp. 229-247
    • Boone, K.G.1    Holder, D.S.2
  • 6
    • 0023087764 scopus 로고
    • The Sheffield data collection system
    • doi: 10.1088/0143-0815/8/4A/012
    • Brown B. H., Seagar A. D. 1987 The Sheffield data collection system. Clin. Phys. Physiol. Meas. 8(suppl A), 91-97 doi: 10.1088/0143-0815/8/4A/012
    • (1987) Clin. Phys. Physiol. Meas. , vol.8 , Issue.SUPPL A , pp. 91-97
    • Brown, B.H.1    Seagar, A.D.2
  • 7
    • 0001718807 scopus 로고
    • Permeability and impermeability of cell membranes for ions
    • Cole K. S. 1940 Permeability and impermeability of cell membranes for ions Symp. Quant. Biol. 8, 110-122
    • (1940) Symp. Quant. Biol. , vol.8 , pp. 110-122
    • Cole, K.S.1
  • 8
    • 33748565282 scopus 로고
    • Dispersion and absorption in dielectrics
    • doi: 10.1063/1.1750906
    • Cole K. S., Cole R. H. 1941 Dispersion and absorption in dielectrics. J. Chem. Phys. 9, 341-351 doi: 10.1063/1.1750906
    • (1941) J. Chem. Phys. , vol.9 , pp. 341-351
    • Cole, K.S.1    Cole, R.H.2
  • 10
    • 0013520333 scopus 로고
    • The electrical conductivity of animal tissues under normal and pathological conditions
    • doi: 10.1119/1.17044
    • Crile G. W., Hosmer H. R., Rowland A. F. 1992 The electrical conductivity of animal tissues under normal and pathological conditions. Am. J. Physiol. 60, 59-106 doi: 10.1119/1.17044
    • (1992) Am. J. Physiol. , vol.60 , pp. 59-106
    • Crile, G.W.1    Hosmer, H.R.2    Rowland, A.F.3
  • 11
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: A critical review
    • Foster K. R., Schwan H. P. 1989 Dielectric properties of tissues and biological materials: a critical review. Crit. Rev. Biomed. Eng. 17, 25-104
    • (1989) Crit. Rev. Biomed. Eng. , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 12
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues-I: Literature survey
    • doi: 10.1088/0031-9155/41/11/001
    • Gabriel C., Gabriel S., Corthout E. 1996 The dielectric properties of biological tissues-I: literature survey. Phys. Med. Biol. 41, 2231-2249 doi: 10.1088/0031-9155/41/11/001
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 13
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues-II: Measurements in the frequency range 10 Hz to 20 GHz
    • doi: 10.1088/0031-9155/41/11/002
    • Gabriel S., Lau R. W., Gabriel C. 1996 The dielectric properties of biological tissues-II: measurements in the frequency range 10 Hz to 20 GHz. Phys. Med. Biol. 41, 2251-2269 doi: 10.1088/0031-9155/41/11/002
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 15
    • 0014986362 scopus 로고
    • An application of electrocardiographic lead theory to impedance plethysmography
    • doi: 10.1109/TBME.1971.4502787
    • Geselowitz D. B. 1971 An application of electrocardiographic lead theory to impedance plethysmography. IEEE Trans. Biomed. Eng. 18, 38-41 doi: 10.1109/TBME.1971.4502787
    • (1971) IEEE Trans. Biomed. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 16
    • 34548184464 scopus 로고    scopus 로고
    • A novel approach for EIT regularization via spatial and spectral principal component analysis
    • doi: 10.1088/0967-3334/28/9/003
    • Goharian, M., M. J. Bruwer, A. Jegatheesan, G. R. Moran, and J. F. MacGregor. A novel approach for EIT regularization via spatial and spectral principal component analysis.Physiol. Meas. 28:1001-1016, 2007. doi: 10.1088/0967-3334/28/9/003
    • (2007) Physiol. Meas. , vol.28 , pp. 1001-1016
    • Goharian, M.1    Bruwer, M.J.2    Jegatheesan, A.3    Moran, G.R.4
  • 17
    • 34247890088 scopus 로고    scopus 로고
    • Dogleg trust-region application in electrical impedance tomography
    • doi: 10.1088/0967-3334/28/5/009
    • Goharian, M., Jegatheesan, A., Moran, G. R., 2007. Dogleg trust-region application in electrical impedance tomography. Physiol. Meas. 28, 555-572 doi: 10.1088/0967-3334/28/5/009
    • (2007) Physiol. Meas. , vol.28 , pp. 555-572
    • Goharian, M.1    Jegatheesan, A.2    Moran, G.R.3
  • 18
    • 34648836877 scopus 로고    scopus 로고
    • Modifying the MRI, elastic stiffness and electrical properties of polyvinyl alcohol cryogel using irradiation
    • doi: 10.1016/j.nimb.2007.04.111
    • Goharian, M., G. R. Moran, K. Wilson, C. Seymour, A. Jegatheesan, M. Hill, R. T. Thompson, and G. Campbell. Modifying the MRI, elastic stiffness and electrical properties of polyvinyl alcohol cryogel using irradiation. Nucl. Instr. Meth. Phys. Res. B, 263(1):239-244, 2007. doi: 10.1016/j.nimb.2007.04.111
    • (2007) Nucl. Instr. Meth. Phys. Res. B , vol.263 , Issue.1 , pp. 239-244
    • Goharian, M.1    Moran, G.R.2    Wilson, K.3    Seymour, C.4    Jegatheesan, A.5    Hill, M.6    Thompson, R.T.7    Campbell, G.8
  • 19
    • 0029022106 scopus 로고
    • A Cole phantom for EIT
    • doi: 10.1088/0967-3334/16/3A/003
    • H. Griffiths 1995 A Cole phantom for EIT Physiol. Meas. 16 suppl A29 A38 10.1088/0967-3334/16/3A/003 Griffiths H. 1995 A Cole phantom for EIT. Physiol. Meas. 16(suppl), A29-A38 doi: 10.1088/0967-3334/16/3A/003
    • (1995) Physiol. Meas. , vol.16 , Issue.SUPPL
    • Griffiths, H.1
  • 20
    • 0028229402 scopus 로고
    • Bioelectric tissue spectroscopy from multifrequency EIT
    • 10.1088/0967-3334/15/2A/008
    • Griffiths, H., and J. Jossinet. Bioelectric tissue spectroscopy from multifrequency EIT. Physiol. Meas. 15(Suppl. 2A):29-35, 1994. doi: 10.1088/0967-3334/15/2A/008
    • (1994) Physiol. Meas. , vol.15 , pp. 29-35
    • Griffiths, H.1    Jossinet, J.2
  • 21
    • 1342290165 scopus 로고    scopus 로고
    • Design and implementation of a high frequency electrical impedance tomography system
    • R. Halter A. Hartov K. D. Paulsen 2004 Design and implementation of a high frequency electrical impedance tomography system Physiol. Meas. 25 379 390 10.1088/0967-3334/25/1/041 Halter R., Hartov A., Paulsen K. D. 2004 Design and implementation of a high frequency electrical impedance tomography system. Physiol. Meas. 25, 379-390 doi: 10.1088/0967-3334/25/1/041
    • (2004) Physiol. Meas. , vol.25 , pp. 379-390
    • Halter, R.1    Hartov, A.2    Paulsen, K.D.3
  • 22
    • 0033962904 scopus 로고    scopus 로고
    • A multi-channel continuously-selectable multi-frequency electrical impedance spectroscopy measurement system
    • doi: 10.1109/10.817619
    • Hartov A., Mazzarese R., Reiss F., Kerner T., Osterman S., Williams D., Paulsen K. A. 2000 A multi-channel continuously-selectable multi-frequency electrical impedance spectroscopy measurement system. IEEE Trans. Biomed. Eng. 47, 49-58 doi: 10.1109/10.817619
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 49-58
    • Hartov, A.1    Mazzarese, R.2    Reiss, F.3    Kerner, T.4    Osterman, S.5    Williams, D.6    Paulsen, K.A.7
  • 24
    • 0034955207 scopus 로고    scopus 로고
    • Front-end architecture for a multi-frequency electrical impedance tomography system
    • doi: 10.1007/BF02345293
    • Jennings D., Schneider I. D. 2001 Front-end architecture for a multi-frequency electrical impedance tomography system. Med. Biol. Eng. Comput. 39, 368-374 doi: 10.1007/BF02345293
    • (2001) Med. Biol. Eng. Comput. , vol.39 , pp. 368-374
    • Jennings, D.1    Schneider, I.D.2
  • 26
    • 34447101159 scopus 로고    scopus 로고
    • A review of errors in multi-frequency EIT instrumentation
    • McEwan M., Cusick G., Holder D. S., 2007, A review of errors in multi-frequency EIT instrumentation. Physiol. Meas., 28, S197-S215
    • (2007) Physiol. Meas. , vol.28
    • Cusick, G.1    Holder, D.S.2
  • 27
    • 33745155784 scopus 로고    scopus 로고
    • Design and calibration of a compact multi-frequency EIT system for acute stroke imaging
    • doi: 10.1088/0967-3334/27/5/S17
    • McEwan A., Romsauerova A., Yerworth R., Horesh L., Bayford R., Holder D. 2006 Design and calibration of a compact multi-frequency EIT system for acute stroke imaging. Physiol. Meas. 27, S199-S210 doi: 10.1088/0967-3334/27/5/S17
    • (2006) Physiol. Meas. , vol.27
    • Romsauerova, A.1    Yerworth, R.2    Horesh, L.3    Bayford, R.4    Holder, D.5
  • 28
    • 36049027812 scopus 로고    scopus 로고
    • Calibration methods for a multi-channel multi-frequency EIT system
    • doi: 10.1088/0967-3334/28/10/004
    • Oh T. I., Lee K. H., Kim S. M., Koo H., Woo E. J., Holder D., 2007, Calibration methods for a multi-channel multi-frequency EIT system. Physiol. Meas., 28, 1175-1188. doi: 10.1088/0967-3334/28/10/004
    • (2007) Physiol. Meas. , vol.28 , pp. 1175-1188
    • Oh, T.I.1    Lee, K.H.2    Kim, S.M.3    Koo, H.4    Woo, E.J.5    Holder, D.6
  • 29
    • 0034003983 scopus 로고    scopus 로고
    • Multifrequency electrical impedance imaging: Preliminary in vivo experience in breast
    • doi: 10.1088/0967-3334/21/1/313 1
    • K. S. Osterman T. E. Kerner D. B. Williams A. Hartov S. P. Poplack K. D. Paulsen 2000 Multifrequency electrical impedance imaging: preliminary in vivo experience in breast Physiol. Meas. 21 1 99 109 10.1088/0967-3334/21/1/313 Osterman K. S., Kerner T. E., Williams D. B., Hartov A., Poplack S. P., Paulsen K. D. 2000 Multifrequency electrical impedance imaging: preliminary in vivo experience in breast. Physiol. Meas. 21(1), 99-109 doi: 10.1088/0967-3334/21/1/ 313
    • (2000) Physiol. Meas. , vol.21 , pp. 99-109
    • Osterman, K.S.1    Kerner, T.E.2    Williams, D.B.3    Hartov, A.4    Poplack, S.P.5    Paulsen, K.D.6
  • 30
    • 0023636426 scopus 로고
    • The passive electrical properties of biological systems: Their significance in physiology, biophysics and biotechnology
    • doi: 10.1088/0031-9155/32/8/001
    • Pethig R., Kell D. B. 1987 The passive electrical properties of biological systems: their significance in physiology, biophysics and biotechnology. Phys. Med. Biol. 32, 933-970 doi: 10.1088/0031-9155/32/8/001
    • (1987) Phys. Med. Biol. , vol.32 , pp. 933-970
    • Pethig, R.1    Kell, D.B.2
  • 32
    • 0029394737 scopus 로고
    • Multi-frequency static imaging in electrical impedance tomography: Part1 instrumentatiion requirement
    • doi: 10.1007/BF02523010
    • Riu P. J., Rosell J., Lozano A., Pallás-Areny R. 1995 Multi-frequency static imaging in electrical impedance tomography: part1 instrumentatiion requirement. Med. Biol. Eng. Comput. 33, 784-792 doi: 10.1007/BF02523010
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 784-792
    • Riu, P.J.1    Rosell, J.2    Lozano, A.3    Pallás-Areny, R.4
  • 33
    • 0026479324 scopus 로고
    • Common-mode feedback in electrical impedance tomography
    • Rosell J., Riu P. 1992 Common-mode feedback in electrical impedance tomography. Clin. Phys. Phsiol. Meas. 13, A11-A14
    • (1992) Clin. Phys. Phsiol. Meas. , vol.13
    • Rosell, J.1    Riu, P.2
  • 34
    • 54949152106 scopus 로고
    • Electrical properties of tissue and cell suspensions
    • Schwan H. P. 1957 Electrical properties of tissue and cell suspensions Adv. Biol. Med. Phys. 5, 147-208
    • (1957) Adv. Biol. Med. Phys. , vol.5 , pp. 147-208
    • Schwan, H.P.1
  • 35
    • 0029239601 scopus 로고
    • A real-time electrical impedance tomography system for clinical use-design and preliminary results
    • doi: 10.1109/10.341825
    • Smith R. W. M., Fresston I. L., Brown B. H. 1995 A real-time electrical impedance tomography system for clinical use-design and preliminary results. IEEE Trans. Biomed. Eng. 42(2), 133-140 doi: 10.1109/10.341825
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.2 , pp. 133-140
    • Smith, R.W.M.1    Fresston, I.L.2    Brown, B.H.3
  • 37
    • 0035115099 scopus 로고    scopus 로고
    • Mk3.5: A modular, multi-frequency successor to the Mk3a EIS/EIT system
    • doi: 10.1088/0967-3334/22/1/307
    • Wilson A. J., Milnes P., Waterworth A. R., Smallwood R. H., Brown B. H. 2001 Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system. Physiol. Meas. 22, 49-54 doi: 10.1088/0967-3334/22/1/307
    • (2001) Physiol. Meas. , vol.22 , pp. 49-54
    • Wilson, A.J.1    Milnes, P.2    Waterworth, A.R.3    Smallwood, R.H.4    Brown, B.H.5
  • 38
    • 0038777520 scopus 로고    scopus 로고
    • Electrical impedance tomography spectroscopy (EITS) for human head imaging
    • doi: 10.1088/0967-3334/24/2/358
    • Yerworth R. J., Bayford R. H., Brown B., Milnes P., Conway M., Holder D. S. 2003 Electrical impedance tomography spectroscopy (EITS) for human head imaging. Physiol. Meas. 24, 477-489 doi: 10.1088/0967-3334/24/2/358
    • (2003) Physiol. Meas. , vol.24 , pp. 477-489
    • Yerworth, R.J.1    Bayford, R.H.2    Brown, B.3    Milnes, P.4    Conway, M.5    Holder, D.S.6
  • 39
    • 0036171902 scopus 로고    scopus 로고
    • Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function
    • doi: 10.1088/0967-3334/23/1/314
    • Yerworth R. J., Bayford R. H., Cusick G., Conway M., Holder D. S. 2002 Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function. Physiol. Meas. 23, 149-158 doi: 10.1088/0967-3334/23/1/314
    • (2002) Physiol. Meas. , vol.23 , pp. 149-158
    • Yerworth, R.J.1    Bayford, R.H.2    Cusick, G.3    Conway, M.4    Holder, D.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.