메뉴 건너뛰기




Volumn 27, Issue 5, 2006, Pages

Design and calibration of a compact multi-frequency EIT system for acute stroke imaging

Author keywords

Acute stroke detection; Calibration; EITS; Multi frequency electrical impedance tomography

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE TOMOGRAPHY; MEDICAL IMAGING; SPECIFICATIONS;

EID: 33745155784     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/5/S17     Document Type: Conference Paper
Times cited : (113)

References (25)
  • 1
    • 0029848301 scopus 로고    scopus 로고
    • Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation
    • Bayford R H, Boone K G, Hanquan Y and Holder D S 1996 Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation Physiol. Meas. 17 A49-57
    • (1996) Physiol. Meas. , vol.17 , Issue.4 A
    • Bayford, R.H.1    Boone, K.G.2    Hanquan, Y.3    Holder, D.S.4
  • 2
    • 0029819404 scopus 로고    scopus 로고
    • Current approaches to analogue instrumentation design in electrical impedance tomography
    • Boone K G and Holder D S 1996 Current approaches to analogue instrumentation design in electrical impedance tomography Physiol. Meas. 17 229-47
    • (1996) Physiol. Meas. , vol.17 , Issue.4 , pp. 229-247
    • Boone, K.G.1    Holder, D.S.2
  • 3
    • 0015300183 scopus 로고
    • Electric shock hazard
    • Dalziel C F 1972 Electric shock hazard IEEE Spectr. 9 41-50
    • (1972) IEEE Spectr. , vol.9 , pp. 41-50
    • Dalziel, C.F.1
  • 5
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: I. Literature Survey
    • Gabriel C, Gabriel S and Corthout E 1996a The dielectric properties of biological tissues: I. Literature Survey Phys. Med. Biol. 41 2231-49
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 6
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • Gabriel S, Lau R and Gabriel C 1996b The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz Phys. Med. Biol. 41 2251-69
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.2    Gabriel, C.3
  • 7
    • 1342290165 scopus 로고    scopus 로고
    • Design and implementation of a high frequency electrical impedance tomography system
    • Halter R, Hartov A and Paulsen K D 2004 Design and implementation of a high frequency electrical impedance tomography system Physiol. Meas. 25 379-90
    • (2004) Physiol. Meas. , vol.25 , Issue.1 , pp. 379-390
    • Halter, R.1    Hartov, A.2    Paulsen, K.D.3
  • 8
    • 0027096024 scopus 로고
    • Electrical impedance tomography (EIT) of brain function
    • Holder D S 1992 Electrical impedance tomography (EIT) of brain function Brain Topogr. 5 87-93
    • (1992) Brain Topogr. , vol.5 , Issue.2 , pp. 87-93
    • Holder, D.S.1
  • 9
    • 0033049822 scopus 로고    scopus 로고
    • Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects
    • Holder D S, Gonzalez-Correa C A, Tidswell T, Gibson A, Cusick G and Bayford R H 1999 Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects Ann. New York Acad. Sci. 873 512-19
    • (1999) Ann. New York Acad. Sci. , vol.873 , pp. 512-519
    • Holder, D.S.1    Gonzalez-Correa, C.A.2    Tidswell, T.3    Gibson, A.4    Cusick, G.5    Bayford, R.H.6
  • 10
    • 0029827279 scopus 로고    scopus 로고
    • Some practical biological phantoms for calibrating multifrequency electrical impedance tomography
    • Holder D S, Hanquan Y and Rao A 1996a Some practical biological phantoms for calibrating multifrequency electrical impedance tomography Physiol. Meas. 17 (Suppl. 4A) A167-77
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL. 4A
    • Holder, D.S.1    Hanquan, Y.2    Rao, A.3
  • 11
    • 0029851449 scopus 로고    scopus 로고
    • Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbit
    • Holder D S, Rao A and Hanquan Y 1996b Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbit Physiol. Meas. 17 (Suppl. 4A) A179-86
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL. 4A
    • Holder, D.S.1    Rao, A.2    Hanquan, Y.3
  • 16
    • 50549163140 scopus 로고
    • Analysis of specific impedance of rabbit cerebral cortex
    • Ranck J B Jr 1963 Analysis of specific impedance of rabbit cerebral cortex Exp. Neurol. 7 153-74
    • (1963) Exp. Neurol. , vol.7 , Issue.2 , pp. 153-174
    • Ranck, J.B.1
  • 17
    • 33745178126 scopus 로고    scopus 로고
    • Identification of a suitable current waveform for acute stroke imaging
    • Romsauerova A, McEwan A and Holder D S 2006 Identification of a suitable current waveform for acute stroke imaging Physiol. Meas. 27 S211-19
    • (2006) Physiol. Meas. , vol.27 , Issue.5
    • Romsauerova, A.1    McEwan, A.2    Holder, D.S.3
  • 19
    • 0038100605 scopus 로고    scopus 로고
    • Current source design for electrical impedance tomography
    • Ross A S, Saulnier G J, Newell J C and Isaacson D 2003 Current source design for electrical impedance tomography Physiol. Meas. 24 509-16
    • (2003) Physiol. Meas. , vol.24 , Issue.2 , pp. 509-516
    • Ross, A.S.1    Saulnier, G.J.2    Newell, J.C.3    Isaacson, D.4
  • 21
    • 0035118995 scopus 로고    scopus 로고
    • Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank
    • Tidswell A T, Gibson A, Bayford R H and Holder D S 2001a Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank Physiol. Meas. 22 177-85
    • (2001) Physiol. Meas. , vol.22 , Issue.1 , pp. 177-185
    • Tidswell, A.T.1    Gibson, A.2    Bayford, R.H.3    Holder, D.S.4
  • 22
    • 0035722843 scopus 로고    scopus 로고
    • Three dimensional impedance tomography of human brain activity
    • Tidswell A, Gibson A, Bayford R and Holder D 2001b Three dimensional impedance tomography of human brain activity Neuroimage 13 283-94
    • (2001) Neuroimage , vol.13 , Issue.2 , pp. 283-294
    • Tidswell, A.1    Gibson, A.2    Bayford, R.3    Holder, D.4
  • 25
    • 0036171902 scopus 로고    scopus 로고
    • Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function
    • Yerworth R J, Bayford R H, Cusick G, Conway M and Holder D S 2002 Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function Physiol. Meas. 23 149-58
    • (2002) Physiol. Meas. , vol.23 , Issue.1 , pp. 149-158
    • Yerworth, R.J.1    Bayford, R.H.2    Cusick, G.3    Conway, M.4    Holder, D.S.5