메뉴 건너뛰기




Volumn 54, Issue 8, 2008, Pages 1349-1355

Commutable calibrator with value assigned by the IFCC reference procedure to harmonize serum lactate dehydrogenase activity results measured by 2 different methods

Author keywords

[No Author keywords available]

Indexed keywords

ISOENZYME; LACTATE DEHYDROGENASE;

EID: 49149102148     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2007.100081     Document Type: Article
Times cited : (15)

References (40)
  • 2
    • 0036328377 scopus 로고    scopus 로고
    • Practice guidelines for tumor marker use in the clinic
    • Sturgeon C. Practice guidelines for tumor marker use in the clinic. Clin Chem 2002;48:1151-9.
    • (2002) Clin Chem , vol.48 , pp. 1151-1159
    • Sturgeon, C.1
  • 3
    • 33947611536 scopus 로고    scopus 로고
    • Lactate dehydrogenase as a prognostic factor for survival time of terminally ill cancer patients: A preliminary study
    • Suh SY, Ahn HY. Lactate dehydrogenase as a prognostic factor for survival time of terminally ill cancer patients: a preliminary study. Eur J Cancer 2007;43:1051-9.
    • (2007) Eur J Cancer , vol.43 , pp. 1051-1059
    • Suh, S.Y.1    Ahn, H.Y.2
  • 7
    • 3242696011 scopus 로고    scopus 로고
    • Severe acute respiratory syndrome (SARS): Epidemiology and clinical features
    • Hui DS, Chan MC, Wu AK, Ng PC. Severe acute respiratory syndrome (SARS): epidemiology and clinical features. Postgrad Med J 2004;80:373-81.
    • (2004) Postgrad Med J , vol.80 , pp. 373-381
    • Hui, D.S.1    Chan, M.C.2    Wu, A.K.3    Ng, P.C.4
  • 8
    • 15244342190 scopus 로고    scopus 로고
    • Chronic lymphocytic leukemia: Novel prognostic factors and their relevance for risk-adapted therapeutic strategies
    • Montillo M, Hamblin T, Hallek M, Montserrat E, Morra E. Chronic lymphocytic leukemia: novel prognostic factors and their relevance for risk-adapted therapeutic strategies. Haematologica 2005;90:391-9.
    • (2005) Haematologica , vol.90 , pp. 391-399
    • Montillo, M.1    Hamblin, T.2    Hallek, M.3    Montserrat, E.4    Morra, E.5
  • 9
    • 10644297501 scopus 로고    scopus 로고
    • Role of biochemical tests in the diagnosis of exudative pleural effusions
    • Ernam D, Atalay F, Hasanoglu HC, Kaplan O. Role of biochemical tests in the diagnosis of exudative pleural effusions. Clin Biochem 2005;38:19-23.
    • (2005) Clin Biochem , vol.38 , pp. 19-23
    • Ernam, D.1    Atalay, F.2    Hasanoglu, H.C.3    Kaplan, O.4
  • 10
    • 49149106989 scopus 로고    scopus 로고
    • Demetriou JA, Drewers PA, Gin JB. Enzymes. In: Henry RJ, Cannon DC, Winkelman JW. Clinical Chemistry: Principles and Techniques, 2nd ed. New York: Harper & Row, 1974;919-32.
    • Demetriou JA, Drewers PA, Gin JB. Enzymes. In: Henry RJ, Cannon DC, Winkelman JW. Clinical Chemistry: Principles and Techniques, 2nd ed. New York: Harper & Row, 1974;919-32.
  • 11
    • 18444372349 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 1. The concept of reference procedure for the measurement of catalytic activity concentrations of enzymes
    • Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 1. The concept of reference procedure for the measurement of catalytic activity concentrations of enzymes. Clin Chem Lab Med 2002;40:631-4.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 631-634
    • Siekmann, L.1    Bonora, R.2    Burtis, C.A.3    Ceriotti, F.4    Clerc-Renaud, P.5    Férard, G.6
  • 12
    • 18444384509 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase
    • Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero CA, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase. Clin Chem Lab Med 2002;40:643-8.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 643-648
    • Schumann, G.1    Bonora, R.2    Ceriotti, F.3    Clerc-Renaud, P.4    Ferrero, C.A.5    Férard, G.6
  • 13
    • 0036367977 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase according to IFCC reference procedures at 37°C
    • Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase according to IFCC reference procedures at 37°C. Clin Chem Lab Med 2002;40:739-45.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 739-745
    • Siekmann, L.1    Bonora, R.2    Burtis, C.A.3    Ceriotti, F.4    Clerc-Renaud, P.5    Férard, G.6
  • 14
    • 0037212005 scopus 로고    scopus 로고
    • New IFCC reference procedures for the determination of catalytic activity concentration of five enzymes in serum: Preliminary upper reference limits obtained in hospitalized subjects
    • Schumann G, Klauke R. New IFCC reference procedures for the determination of catalytic activity concentration of five enzymes in serum: preliminary upper reference limits obtained in hospitalized subjects. Clin Chim Acta 2003;327:69-79.
    • (2003) Clin Chim Acta , vol.327 , pp. 69-79
    • Schumann, G.1    Klauke, R.2
  • 16
    • 33746915004 scopus 로고    scopus 로고
    • Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum: An international study in the EC4 framework of Calibration 2000 project
    • Jansen R, Schumann G, Baadenhuijsen H, Franck P, Franzini C, Kruse R, et al. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum: an international study in the EC4 framework of Calibration 2000 project. Clin Chim Acta 2006;368:160-7.
    • (2006) Clin Chim Acta , vol.368 , pp. 160-167
    • Jansen, R.1    Schumann, G.2    Baadenhuijsen, H.3    Franck, P.4    Franzini, C.5    Kruse, R.6
  • 17
    • 49149112450 scopus 로고    scopus 로고
    • Accessed February 2008
    • QCNet. http://sde.qcnet.com/sde/reports/unityWWReports.aspx (Accessed February 2008).
    • QCNet
  • 18
    • 0030932213 scopus 로고    scopus 로고
    • Vocabulary for use in measurement procedures and description of reference materials in laboratory medicine
    • Dybkaer R. Vocabulary for use in measurement procedures and description of reference materials in laboratory medicine. Eur J Clin Chem Clin Biochem 1997;35:141-73.
    • (1997) Eur J Clin Chem Clin Biochem , vol.35 , pp. 141-173
    • Dybkaer, R.1
  • 19
    • 49149109938 scopus 로고    scopus 로고
    • International Standards Organization. In vitro diagnostic medical devices: measurement of quantities in biological samples - metrological traceability of values assigned to calibrators and control materials. ISO/FDIS 17511, 2002.
    • International Standards Organization. In vitro diagnostic medical devices: measurement of quantities in biological samples - metrological traceability of values assigned to calibrators and control materials. ISO/FDIS 17511, 2002.
  • 20
    • 0015544175 scopus 로고
    • A discussion of enzyme reference materials: Applications and specifications
    • Fasce CF Jr, Rej R, Copeland WH, Vanderlinde RE. A discussion of enzyme reference materials: applications and specifications. Clin Chem 1973;19:5-9.
    • (1973) Clin Chem , vol.19 , pp. 5-9
    • Fasce Jr, C.F.1    Rej, R.2    Copeland, W.H.3    Vanderlinde, R.E.4
  • 21
    • 0027375825 scopus 로고
    • Commutability of reference materials in clinical chemistry
    • Franzini C. Commutability of reference materials in clinical chemistry. J Int Fed Clin Chem 1993;5:169-73.
    • (1993) J Int Fed Clin Chem , vol.5 , pp. 169-173
    • Franzini, C.1
  • 22
    • 0027419761 scopus 로고
    • Accurate enzyme activity measurements: Two decades of development in the commutability of enzyme quality control materials
    • Rej R. Accurate enzyme activity measurements: two decades of development in the commutability of enzyme quality control materials. Arch Pathol Lab Med 1993;117:352-64.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 352-364
    • Rej, R.1
  • 24
    • 0032146055 scopus 로고    scopus 로고
    • Impact of reference materials on accuracy in clinical chemistry
    • Franzini C, Ceriotti F. Impact of reference materials on accuracy in clinical chemistry. Clin Biochem 1998;31:449-57.
    • (1998) Clin Biochem , vol.31 , pp. 449-457
    • Franzini, C.1    Ceriotti, F.2
  • 25
    • 0037212728 scopus 로고    scopus 로고
    • Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes
    • Miller WG. Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. Clin Chim Acta 2003;327:25-37.
    • (2003) Clin Chim Acta , vol.327 , pp. 25-37
    • Miller, W.G.1
  • 26
    • 0035196397 scopus 로고    scopus 로고
    • Commutability of calibration and control materials for serum lipase
    • Cattozzo G, Franzini C, Melzi d'Eril G. Commutability of calibration and control materials for serum lipase. Clin Chem 2001;47:2108-13.
    • (2001) Clin Chem , vol.47 , pp. 2108-2113
    • Cattozzo, G.1    Franzini, C.2    Melzi d'Eril, G.3
  • 27
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods: Applications of linear regression procedures for method comparison studies in clinical chemistry
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods: applications of linear regression procedures for method comparison studies in clinical chemistry. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 28
    • 0018404684 scopus 로고
    • Comparison of intermethod analytical variability of patient sera and commercial quality control sera
    • van Helden WC, Visser RW, Van den Bergh FA, Souverijn JH. Comparison of intermethod analytical variability of patient sera and commercial quality control sera. Clin Chim Acta 1979;93:335-47.
    • (1979) Clin Chim Acta , vol.93 , pp. 335-347
    • van Helden, W.C.1    Visser, R.W.2    Van den Bergh, F.A.3    Souverijn, J.H.4
  • 29
    • 0031970811 scopus 로고    scopus 로고
    • Characterisation and evaluation of external quality assessment scheme serum
    • Middle JG, Libeer JC, Malakhov V, Penttila I. Characterisation and evaluation of external quality assessment scheme serum. Clin Chem Lab Med 1998;36:119-30.
    • (1998) Clin Chem Lab Med , vol.36 , pp. 119-130
    • Middle, J.G.1    Libeer, J.C.2    Malakhov, V.3    Penttila, I.4
  • 30
    • 0035142454 scopus 로고    scopus 로고
    • Myoglobin and creatine kinase MB mass assays: Intermethod variability of patient sera and commercially available control materials
    • Cattozzo G, Franzini C, Melzi d'Eril GV. Myoglobin and creatine kinase MB mass assays: intermethod variability of patient sera and commercially available control materials. Clin Chim Acta 2001;303:55-60.
    • (2001) Clin Chim Acta , vol.303 , pp. 55-60
    • Cattozzo, G.1    Franzini, C.2    Melzi d'Eril, G.V.3
  • 31
    • 0035210332 scopus 로고    scopus 로고
    • Commutability of serum protein values: Persisting bias among manufacturers using values assigned from the certified reference material 470 (CRM 470) in the United States
    • Ledue TB, Johnson AM. Commutability of serum protein values: persisting bias among manufacturers using values assigned from the certified reference material 470 (CRM 470) in the United States. Clin Chem Lab Med 2001;39:1129-33.
    • (2001) Clin Chem Lab Med , vol.39 , pp. 1129-1133
    • Ledue, T.B.1    Johnson, A.M.2
  • 32
    • 33645457084 scopus 로고    scopus 로고
    • Why commutability matters [Editorial]
    • Miller WG, Myers GL, Rej R. Why commutability matters [Editorial]. Clin Chem 2006;52:553-4.
    • (2006) Clin Chem , vol.52 , pp. 553-554
    • Miller, W.G.1    Myers, G.L.2    Rej, R.3
  • 34
    • 0033636288 scopus 로고    scopus 로고
    • Implementation of reference systems in laboratory medicine
    • Muller MM. Implementation of reference systems in laboratory medicine. Clin Chem 2000;46:1907-9.
    • (2000) Clin Chem , vol.46 , pp. 1907-1909
    • Muller, M.M.1
  • 35
    • 17044380940 scopus 로고    scopus 로고
    • External quality assessment in The Netherlands: Time to introduce commutable survey specimens. Lessons from the Dutch "Calibration 2000" project
    • Baadenhuijsen H, Kuypers A, Weykamp C, Cobbaert C, Jansen R. External quality assessment in The Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch "Calibration 2000" project. Clin Chem Lab Med 2005;43:304-7.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 304-307
    • Baadenhuijsen, H.1    Kuypers, A.2    Weykamp, C.3    Cobbaert, C.4    Jansen, R.5
  • 36
    • 33748319372 scopus 로고    scopus 로고
    • Towards standardization of cardiac troponin I measurement. Part II: Assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays
    • Christenson RH, Duh SH, Apple FS, Bodor GS, Bunk DM, Panteghini M, et al. Towards standardization of cardiac troponin I measurement. Part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays. Clin Chem 2006;52:1685-92.
    • (2006) Clin Chem , vol.52 , pp. 1685-1692
    • Christenson, R.H.1    Duh, S.H.2    Apple, F.S.3    Bodor, G.S.4    Bunk, D.M.5    Panteghini, M.6
  • 37
    • 49149085064 scopus 로고    scopus 로고
    • Preparation and validation of commutable frozen human serum pools as secondary reference materials for cholesterol measurement procedures; approved guideline
    • Myers GL, Eckfeldt JH, Greenberg N, Levine JB, Miller WG, Wiebe DA. Preparation and validation of commutable frozen human serum pools as secondary reference materials for cholesterol measurement procedures; approved guideline. NCCLS C37-A, 1999.
    • (1999) NCCLS , vol.C37-A
    • Myers, G.L.1    Eckfeldt, J.H.2    Greenberg, N.3    Levine, J.B.4    Miller, W.G.5    Wiebe, D.A.6
  • 40
    • 49149101903 scopus 로고    scopus 로고
    • International Standards Organization. In vitro diagnostic medical devices: measurement of quantities in samples of biological origin - metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO/FDIS 18153, 2003.
    • International Standards Organization. In vitro diagnostic medical devices: measurement of quantities in samples of biological origin - metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO/FDIS 18153, 2003.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.