메뉴 건너뛰기




Volumn 10, Issue 12, 2008, Pages 2593-2596

Total synthesis of sanguiin H-5

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL PRODUCT; SANGUIIN H 5; SANGUIIN H-5; TANNIN;

EID: 48849100053     PISSN: 15237060     EISSN: None     Source Type: Journal    
DOI: 10.1021/ol8009545     Document Type: Article
Times cited : (54)

References (23)
  • 3
    • 0001308223 scopus 로고    scopus 로고
    • and references therein
    • (c) Quideau, S.; Feldman, K. S. Chem. Rev. 1996, 96, 475-503, and references therein.
    • (1996) Chem. Rev , vol.96 , pp. 475-503
    • Quideau, S.1    Feldman, K.S.2
  • 15
    • 0029842857 scopus 로고    scopus 로고
    • Feldman, K. S. Personal communication. Feldman, K. S.; Quideau, S.; Appel, H. M. J. Org. Chem. 1996, 61, 6656.
    • Feldman, K. S. Personal communication. Feldman, K. S.; Quideau, S.; Appel, H. M. J. Org. Chem. 1996, 61, 6656.
  • 16
    • 59949087282 scopus 로고    scopus 로고
    • Methods examined: (i) Electrophilic iodination: Molander, G. A.; George, K. M.; Monovich, L. G. J. Org. Chem. 2003, 68, 9533.
    • (a) Methods examined: (i) Electrophilic iodination: Molander, G. A.; George, K. M.; Monovich, L. G. J. Org. Chem. 2003, 68, 9533.
  • 19
    • 59949092542 scopus 로고    scopus 로고
    • Suzuki's oxidative conditions: (d) Suzuki, H. Bull. Chem. Soc. Jpn. 1971, 44, 2871
    • (ii) Suzuki's oxidative conditions: (d) Suzuki, H. Bull. Chem. Soc. Jpn. 1971, 44, 2871
  • 20
    • 0037424307 scopus 로고    scopus 로고
    • Directed ortho-lithiation and iodine quench: (e) Gohier, F.; Mortier, J. J. Org. Chem. 2003, 68, 2030.
    • (iii) Directed ortho-lithiation and iodine quench: (e) Gohier, F.; Mortier, J. J. Org. Chem. 2003, 68, 2030.
  • 22
    • 0034596358 scopus 로고    scopus 로고
    • Chem. Soc, NB: NaH was used as the base in this reported synthesis
    • Feldman, K. S.; Lawlor, M. D., J. Am. Chem. Soc. 2000, 122, 7396-7397, NB: NaH was used as the base in this reported synthesis.
    • (2000) J. Am , vol.122 , pp. 7396-7397
    • Feldman, K.S.1    Lawlor, M.D.2
  • 23
    • 59949101223 scopus 로고    scopus 로고
    • Choromatography using reversed-phase (C-18) silica could be used if required; however, the filtered, concentrated reaction mixture gave material of ca. 95% purity.
    • Choromatography using reversed-phase (C-18) silica could be used if required; however, the filtered, concentrated reaction mixture gave material of ca. 95% purity.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.