메뉴 건너뛰기




Volumn 8, Issue 3, 2008, Pages 149-158

Effects of muscle pump on rotary blood pumps in dynamic exercise: A computer simulation study

Author keywords

Left ventricular assist device; Muscle pump; Numerical model; Rotary blood pump

Indexed keywords

ARTICLE; BLOOD PUMP; COMPUTER PROGRAM; COMPUTER SIMULATION; DIASTOLE; DYNAMIC EXERCISE; HEART LEFT VENTRICLE FUNCTION; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HEART VENTRICLE PRESSURE; HEMODYNAMIC PARAMETERS; HUMAN; MATHEMATICAL COMPUTING; MUSCLE BLOOD FLOW; MUSCLE EXERCISE; MUSCLE FUNCTION; SYSTOLE; VASCULAR RESISTANCE;

EID: 48549096009     PISSN: 15678822     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10558-008-9056-x     Document Type: Article
Times cited : (9)

References (37)
  • 1
    • 0024344273 scopus 로고
    • Linearity of the left ventricular end-systolic pressure-volume relation in patients with severe heart failure
    • Aroney CN, Herrmann HC, Semigran MJ, et al. Linearity of the left ventricular end-systolic pressure-volume relation in patients with severe heart failure. J Am Coll Cardiol. 1989;14:127-134.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 127-134
    • Aroney, C.N.1    Herrmann, H.C.2    Semigran, M.J.3
  • 3
    • 0023789871 scopus 로고
    • Human right ventricular end-systolic pressure-volume relation defined by maximal elastance
    • Brown KA, Ditchey RV. Human right ventricular end-systolic pressure-volume relation defined by maximal elastance. Circulation. 1988;78:81-91.
    • (1988) Circulation , vol.78 , pp. 81-91
    • Brown, K.A.1    Ditchey, R.V.2
  • 4
    • 0021294040 scopus 로고
    • Triple control of relaxation: Implications in cardiac disease
    • Brutsaert DL, Rademaker FE, Sys SU. Triple control of relaxation: implications in cardiac disease. Circulation. 1984;69:190-196.
    • (1984) Circulation , vol.69 , pp. 190-196
    • Brutsaert, D.L.1    Rademaker, F.E.2    Sys, S.U.3
  • 6
    • 23944456315 scopus 로고    scopus 로고
    • Physiological control of left ventricular assist devices based on gradient of flow
    • Portland, OR, June
    • Chen S, Antaki JF, Simaan MA, et al. Physiological control of left ventricular assist devices based on gradient of flow. Proceeding of American control conference, pp 3829-3834, Portland, OR, June 2005.
    • (2005) Proceeding of American Control Conference , pp. 3829-3834
    • Chen, S.1    Antaki, J.F.2    Simaan, M.A.3
  • 8
    • 0025254439 scopus 로고
    • Redistribution of regional and organ blood volume and effect on cardiac function in relation to upright exercise intensity in healthy human subjects
    • Flamm SD, Taki J, et al. Redistribution of regional and organ blood volume and effect on cardiac function in relation to upright exercise intensity in healthy human subjects. Circulation. 1990;81:1550-1559.
    • (1990) Circulation , vol.81 , pp. 1550-1559
    • Flamm, S.D.1    Taki, J.2
  • 9
    • 0023755287 scopus 로고
    • Redistribution of visceral blood volume in upright exercise in healthy volunteers
    • Froelich JW, Strauss HW, Moore RH, Mckusick KA. Redistribution of visceral blood volume in upright exercise in healthy volunteers. J Nucl Med. 1988;29:1714-1718.
    • (1988) J Nucl Med , vol.29 , pp. 1714-1718
    • Froelich, J.W.1    Strauss, H.W.2    Moore, R.H.3    Mckusick, K.A.4
  • 10
    • 0016592127 scopus 로고
    • Dynamic determinants of left ventricular diastolic pressure-volume relations in man
    • Gaasch WH, Cole JS, Quinones MA, Alexander JK. Dynamic determinants of left ventricular diastolic pressure-volume relations in man. Circulation. 1975;51:317-323.
    • (1975) Circulation , vol.51 , pp. 317-323
    • Gaasch, W.H.1    Cole, J.S.2    Quinones, M.A.3    Alexander, J.K.4
  • 11
    • 33645474358 scopus 로고    scopus 로고
    • Physiological control of blood pumps using intrinsic pump parameters: A computer simulation study
    • Giridharan GA, Skliar M. Physiological control of blood pumps using intrinsic pump parameters: A computer simulation study. Artif Organs. 2006;30(4):301-307.
    • (2006) Artif Organs , vol.30 , Issue.4 , pp. 301-307
    • Giridharan, G.A.1    Skliar, M.2
  • 12
    • 15444379970 scopus 로고    scopus 로고
    • Magnevad - The world's smallest magnetic-bearing turbo pump
    • Goldowsky M. Magnevad - the world's smallest magnetic-bearing turbo pump. Artif Organs. 2004;28(10):945-52.
    • (2004) Artif Organs , vol.28 , Issue.10 , pp. 945-952
    • Goldowsky, M.1
  • 14
    • 12844273500 scopus 로고    scopus 로고
    • Magnetically suspended centrifugal blood pump with a radial magnetic driver
    • Hoshi H, Katakoa K, Ohuchi K, et al. Magnetically suspended centrifugal blood pump with a radial magnetic driver. ASAIO J. 2005;51(1):60-4.
    • (2005) ASAIO J , vol.51 , Issue.1 , pp. 60-64
    • Hoshi, H.1    Katakoa, K.2    Ohuchi, K.3
  • 15
    • 0031993767 scopus 로고    scopus 로고
    • The influence of left systolic ventricular function on right ventricular function after an acute myocardial infarct
    • Izzo A, Galderisi M, de Divitiis O. The influence of left systolic ventricular function on right ventricular function after an acute myocardial infarct. Cardiologia. 1998;43(2):173-80.
    • (1998) Cardiologia , vol.43 , Issue.2 , pp. 173-180
    • Izzo, A.1    Galderisi, M.2    de Divitiis, O.3
  • 16
    • 0023521066 scopus 로고
    • Skeletal muscle blood flow capacity: Role of muscle pump in exercise hyperemia
    • Laughlin MH. Skeletal muscle blood flow capacity: Role of muscle pump in exercise hyperemia. Am J Physiol. 1987;253:H993-H1004.
    • (1987) Am J Physiol , vol.253
    • Laughlin, M.H.1
  • 17
    • 0036865683 scopus 로고    scopus 로고
    • Cardiovascular response to dynamic aerobic exercise: A mathematical model
    • Magosso E, Ursino M. Cardiovascular response to dynamic aerobic exercise: A mathematical model. Med Biol Eng Comput. 2002;40:660-70.
    • (2002) Med Biol Eng Comput , vol.40 , pp. 660-670
    • Magosso, E.1    Ursino, M.2
  • 18
    • 0020578340 scopus 로고
    • The effect of pulmonary hypertension on systolic function of the right ventricle
    • Morrison D, Goldman S, Wright AL, et al. The effect of pulmonary hypertension on systolic function of the right ventricle. Chest. 1983;84:250-7.
    • (1983) Chest , vol.84 , pp. 250-257
    • Morrison, D.1    Goldman, S.2    Wright, A.L.3
  • 19
    • 0029847984 scopus 로고    scopus 로고
    • Central venous pressure during exercise: Role of muscle pump
    • Notarius CF, Magder S. Central venous pressure during exercise: Role of muscle pump. Can J Physiol Pharmacol. 1996;47:647-51.
    • (1996) Can J Physiol Pharmacol , vol.47 , pp. 647-651
    • Notarius, C.F.1    Magder, S.2
  • 21
    • 0018188256 scopus 로고
    • Diastolic left ventricular pressure-volume and stress-strain relations in patients with valvular aortic stenosis and left ventricular hypertrophy
    • Peterson KL, Tsuji J, Johnson A, Didonna J, Lewinter M. Diastolic left ventricular pressure-volume and stress-strain relations in patients with valvular aortic stenosis and left ventricular hypertrophy. Circulation. 1978;58(1):77-89.
    • (1978) Circulation , vol.58 , Issue.1 , pp. 77-89
    • Peterson, K.L.1    Tsuji, J.2    Johnson, A.3    Didonna, J.4    Lewinter, M.5
  • 22
    • 33750873556 scopus 로고    scopus 로고
    • Muscle blood flow at onset of dynamic exercise in humans
    • Radegran G, Saltin B. Muscle blood flow at onset of dynamic exercise in humans. Am J Physiol. 1998;274:H314-H322.
    • (1998) Am J Physiol , vol.274
    • Radegran, G.1    Saltin, B.2
  • 24
    • 0031964853 scopus 로고    scopus 로고
    • Ventricular interdependence: Significant left ventricular contributions to right ventricular systolic function
    • Santamore WP, Dell'Italia LJ. Ventricular interdependence: Significant left ventricular contributions to right ventricular systolic function. Prog Cardiovasc Dis. 1998;40:289-308.
    • (1998) Prog Cardiovasc Dis , vol.40 , pp. 289-308
    • Santamore, W.P.1    Dell'Italia, L.J.2
  • 25
    • 31544453866 scopus 로고    scopus 로고
    • First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization
    • Schima H, Vollkron M, Jantsch U, et al. First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization. J Heart Lung Transp. 2006;25(2):167-73.
    • (2006) J Heart Lung Transp , vol.25 , Issue.2 , pp. 167-173
    • Schima, H.1    Vollkron, M.2    Jantsch, U.3
  • 26
    • 33750819952 scopus 로고    scopus 로고
    • Flow-generating capability of the isolated skeletal muscle pump
    • Sheriff DD, Bibber RV. Flow-generating capability of the isolated skeletal muscle pump. Am J Physiol. 1998;274:H1502-8.
    • (1998) Am J Physiol , vol.274
    • Sheriff, D.D.1    Bibber, R.V.2
  • 27
    • 0027440116 scopus 로고
    • Is rapid rise in vascular conductance at onset of dynamic exercise due to muscle pump?
    • Sheriff DD, Rowell LB, Scher AM. Is rapid rise in vascular conductance at onset of dynamic exercise due to muscle pump? Am J Physiol. 1993;265:H1227-34.
    • (1993) Am J Physiol , vol.265
    • Sheriff, D.D.1    Rowell, L.B.2    Scher, A.M.3
  • 28
    • 0017159837 scopus 로고
    • Integrated mechanisms of cardiovascular response and control during exercise in the normal human
    • Smith EE, Guyton AC, Manning RD, White RJ. Integrated mechanisms of cardiovascular response and control during exercise in the normal human. Prog Cardiovasc Dis. 1976;18(6):421-41.
    • (1976) Prog Cardiovasc Dis , vol.18 , Issue.6 , pp. 421-441
    • Smith, E.E.1    Guyton, A.C.2    Manning, R.D.3    White, R.J.4
  • 29
    • 0030926834 scopus 로고    scopus 로고
    • Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump
    • Tsukiya T, Akamatsu T, et al. Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump. Artif Organs. 1997;21(5):396-401.
    • (1997) Artif Organs , vol.21 , Issue.5 , pp. 396-401
    • Tsukiya, T.1    Akamatsu, T.2
  • 30
    • 0030967980 scopus 로고    scopus 로고
    • Assessment of right ventricular contractile function in patients with left ventricular dysfunction by a simplified echocardiographic subtraction method
    • Tomita M, Yagi Y, Gotoh K, Fujiwara H. Assessment of right ventricular contractile function in patients with left ventricular dysfunction by a simplified echocardiographic subtraction method. J Cardiol - Suppl. 1997;29(2):63-71.
    • (1997) J Cardiol - Suppl , vol.29 , Issue.2 , pp. 63-71
    • Tomita, M.1    Yagi, Y.2    Gotoh, K.3    Fujiwara, H.4
  • 31
    • 27744605262 scopus 로고    scopus 로고
    • Numerical, experimental analysis of an axial flow left ventricular assist device the influence of the diffuser on overall pump performance
    • Untaroiu A, Throckmorton AL, Patel SM, et al. Numerical, experimental analysis of an axial flow left ventricular assist device the influence of the diffuser on overall pump performance. Artif Organs. 2005;29(7):581-91.
    • (2005) Artif Organs , vol.29 , Issue.7 , pp. 581-591
    • Untaroiu, A.1    Throckmorton, A.L.2    Patel, S.M.3
  • 32
    • 0036240115 scopus 로고    scopus 로고
    • Interaction of the cardiovascular system with an implanted rotary assist device: Simulation study with a refined computer model
    • Vollkron M, Schima H, Huber L, Wieselthaler G. Interaction of the cardiovascular system with an implanted rotary assist device: Simulation study with a refined computer model. Artif Organs. 2002;26(4):349-59.
    • (2002) Artif Organs , vol.26 , Issue.4 , pp. 349-359
    • Vollkron, M.1    Schima, H.2    Huber, L.3    Wieselthaler, G.4
  • 33
    • 27644535295 scopus 로고    scopus 로고
    • Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changes
    • Wohlschlaeger J, Schmitz KJ, Schmid C, Schmid KW, Keul P, Takeda A, et al. Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changes. Cardiovasc Res. 2005;68(3):376-86.
    • (2005) Cardiovasc Res , vol.68 , Issue.3 , pp. 376-386
    • Wohlschlaeger, J.1    Schmitz, K.J.2    Schmid, C.3    Schmid, K.W.4    Keul, P.5    Takeda, A.6
  • 34
    • 34447335841 scopus 로고    scopus 로고
    • Modeling, estimation, and control of human circulatory systems with a left ventricular assist device
    • Wu Y, Allaire PE, Tao G, Olsen DB. Modeling, estimation, and control of human circulatory systems with a left ventricular assist device. IEEE Trans Control Syst Technol. 2007;15(4):754-67.
    • (2007) IEEE Trans Control Syst Technol , vol.15 , Issue.4 , pp. 754-767
    • Wu, Y.1    Allaire, P.E.2    Tao, G.3    Olsen, D.B.4
  • 35
    • 0034282863 scopus 로고    scopus 로고
    • Computer modeling of interaction of an electric motor, circulatory system, and rotary blood pump
    • Xu L, Fu M. Computer modeling of interaction of an electric motor, circulatory system, and rotary blood pump. ASAIO J. 2000;46:604-11.
    • (2000) ASAIO J , vol.46 , pp. 604-611
    • Xu, L.1    Fu, M.2
  • 36
    • 0015803022 scopus 로고
    • Peripheral circulatory control mechanisms in congestive heart failure
    • Zelis R, Longhurst FJ, Capone RJ, Lee G. Peripheral circulatory control mechanisms in congestive heart failure. Am J Cardiol. 1973;32:481-90.
    • (1973) Am J Cardiol , vol.32 , pp. 481-490
    • Zelis, R.1    Longhurst, F.J.2    Capone, R.J.3    Lee, G.4
  • 37
    • 0032601377 scopus 로고    scopus 로고
    • Numerical modeling of the cardiovascular system with a left ventricular assist device
    • Zhou J, Armstrong GP, Medvedev AL, et al. Numerical modeling of the cardiovascular system with a left ventricular assist device. ASAIO J. 1999;45:83-89.
    • (1999) ASAIO J , vol.45 , pp. 83-89
    • Zhou, J.1    Armstrong, G.P.2    Medvedev, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.