-
2
-
-
0034546122
-
Control system architecture for mechanical cardiac assist devices
-
B. Paden, J. Ghosh, and J. Antaki, "Control system architecture for mechanical cardiac assist devices," in Proc. Amer. Control Conf., 2000, pp. 3478-3482.
-
(2000)
Proc. Amer. Control Conf
, pp. 3478-3482
-
-
Paden, B.1
Ghosh, J.2
Antaki, J.3
-
4
-
-
34447345043
-
-
Y. Wu, Design and testing of a physiologic control system for an artificial heart pump, Ph.D. dissertation, Univ. Virginia, Charlottesville, 2004.
-
Y. Wu, "Design and testing of a physiologic control system for an artificial heart pump," Ph.D. dissertation, Univ. Virginia, Charlottesville, 2004.
-
-
-
-
5
-
-
0032975726
-
A new control method that estimates the backflow in a centrifugal pump
-
K. Nakata and G. Ohtsuka et al., "A new control method that estimates the backflow in a centrifugal pump," Artif. Organs, vol. 23, no. 6, pp. 538-541, 1999.
-
(1999)
Artif. Organs
, vol.23
, Issue.6
, pp. 538-541
-
-
Nakata, K.1
Ohtsuka, G.2
-
6
-
-
0032838992
-
Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study
-
T. Akimoto and K. Yamazaki et al., "Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study," Artif. Organs, vol. 23, no. 8, pp. 797-801, 1999.
-
(1999)
Artif. Organs
, vol.23
, Issue.8
, pp. 797-801
-
-
Akimoto, T.1
Yamazaki, K.2
-
7
-
-
0031239274
-
Progress in the development of a transcutaneously powered axial flow blood pump ventricular assist system
-
S. M. Parnis and J. L. Conger et al., "Progress in the development of a transcutaneously powered axial flow blood pump ventricular assist system," ASAIO J., vol. 43, pp. M576-M580, 1997.
-
(1997)
ASAIO J
, vol.43
-
-
Parnis, S.M.1
Conger, J.L.2
-
8
-
-
0004019181
-
-
4th ed. St. Louis, MI: Mosby Inc
-
R. M. Berne and M. N. Levy, Physiology, 4th ed. St. Louis, MI: Mosby Inc., 1998, pp. 504-506.
-
(1998)
Physiology
, pp. 504-506
-
-
Berne, R.M.1
Levy, M.N.2
-
9
-
-
0033017790
-
Motor feedback physiological control for a continuous flow ventricular assist device
-
T. Waters, P. Allaire, and G. Tao et al., "Motor feedback physiological control for a continuous flow ventricular assist device," Artif. Organs, vol. 23, no. 6, pp. 480-487, 1999.
-
(1999)
Artif. Organs
, vol.23
, Issue.6
, pp. 480-487
-
-
Waters, T.1
Allaire, P.2
Tao, G.3
-
10
-
-
0034098785
-
Computer simulation of sensorless fuzzy control of a rotary blood pump to assure normal physiology
-
M. Fu and L. Xu, "Computer simulation of sensorless fuzzy control of a rotary blood pump to assure normal physiology," ASAIO J., vol. 46, no. 3, pp. 273-278, 2000.
-
(2000)
ASAIO J
, vol.46
, Issue.3
, pp. 273-278
-
-
Fu, M.1
Xu, L.2
-
11
-
-
0035337515
-
A sensorless approach to control of a turbodynamic left ventricular assist system
-
May
-
S. Choi, J. F. Antaki, J. R. Boston, and D. Thomas, "A sensorless approach to control of a turbodynamic left ventricular assist system," IEEE Trans. Control Syst. Technol., vol. 9, no. 3, pp. 473-482, May 2001.
-
(2001)
IEEE Trans. Control Syst. Technol
, vol.9
, Issue.3
, pp. 473-482
-
-
Choi, S.1
Antaki, J.F.2
Boston, J.R.3
Thomas, D.4
-
12
-
-
0036558955
-
Modeling and control of a brushless DC axial flow ventricular assist device
-
G. A. Giridharan, M. Skliar, D. B. Olsen, and G. M. Pantalos, "Modeling and control of a brushless DC axial flow ventricular assist device," ASAIO J., vol. 48, pp. 272-289, 2002.
-
(2002)
ASAIO J
, vol.48
, pp. 272-289
-
-
Giridharan, G.A.1
Skliar, M.2
Olsen, D.B.3
Pantalos, G.M.4
-
13
-
-
0034545599
-
Control issue in rotary heart assist devices
-
J. R. Boston, M. A. Simaan, J. F. Antaki, and Y. Yu, "Control issue in rotary heart assist devices," in Proc. Amer. Control Conf., 2000, pp. 3473-3477.
-
(2000)
Proc. Amer. Control Conf
, pp. 3473-3477
-
-
Boston, J.R.1
Simaan, M.A.2
Antaki, J.F.3
Yu, Y.4
-
14
-
-
22844448779
-
Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing
-
Apr
-
Y. Liu, P. E. Allaire, H. G.Wood, and D. B. Olsen, "Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing," Artif. Organs, vol. 29, no. 4, pp. 341-345, Apr. 2005.
-
(2005)
Artif. Organs
, vol.29
, Issue.4
, pp. 341-345
-
-
Liu, Y.1
Allaire, P.E.2
Wood, H.G.3
Olsen, D.B.4
-
15
-
-
0033839985
-
Sensorless controlling method for a continuous flow left ventricular assist device
-
M. Oshikawa, K. Araki, G. Endo, H. Anai, and M. Sato, "Sensorless controlling method for a continuous flow left ventricular assist device," Artif. Organs, vol. 24, no. 8, pp. 600-605, 2000.
-
(2000)
Artif. Organs
, vol.24
, Issue.8
, pp. 600-605
-
-
Oshikawa, M.1
Araki, K.2
Endo, G.3
Anai, H.4
Sato, M.5
-
16
-
-
0034823945
-
Control strategy for rotary blood pumps
-
K. Ohuchi and D. Kikugawa et al., "Control strategy for rotary blood pumps," Artif. Organs, vol. 25, no. 5, pp. 366-370, 2001.
-
(2001)
Artif. Organs
, vol.25
, Issue.5
, pp. 366-370
-
-
Ohuchi, K.1
Kikugawa, D.2
-
17
-
-
0034540608
-
Control of rotary heart assist devices
-
L. A. Baloa, D. Liu, J. R. Boston, M. A. Simaan, and J. F Antaki, "Control of rotary heart assist devices," in Proc. Amer. Control Conf., 2000, pp. 2982-2986.
-
(2000)
Proc. Amer. Control Conf
, pp. 2982-2986
-
-
Baloa, L.A.1
Liu, D.2
Boston, J.R.3
Simaan, M.A.4
Antaki, J.F.5
-
18
-
-
0030795951
-
Control of centrifugal pump based on the motor current
-
T. Iijima, T. Inamoto, M. Nogawa, and S. Takatani, "Control of centrifugal pump based on the motor current," Artif. Organs, vol. 21, no. 7, pp. 665-660, 1997.
-
(1997)
Artif. Organs
, vol.21
, Issue.7
, pp. 665-660
-
-
Iijima, T.1
Inamoto, T.2
Nogawa, M.3
Takatani, S.4
-
19
-
-
0031239168
-
Controller for an axial-flow blood pump
-
D. V. Amin, J. F. Antaki, and P. Litwak, "Controller for an axial-flow blood pump," Biomed. Instrum. Technol., vol. 31, pp. 483-487, 1997.
-
(1997)
Biomed. Instrum. Technol
, vol.31
, pp. 483-487
-
-
Amin, D.V.1
Antaki, J.F.2
Litwak, P.3
-
20
-
-
3843055632
-
Development of a suction detection system for axial blood pumps
-
M. Vollkron, H. Schima, L. Huber, R. Benkowski, G. Morello, and G. Wieselthaler, "Development of a suction detection system for axial blood pumps," Artif. Organs, vol. 28, no. 8, pp. 709-716, 2004.
-
(2004)
Artif. Organs
, vol.28
, Issue.8
, pp. 709-716
-
-
Vollkron, M.1
Schima, H.2
Huber, L.3
Benkowski, R.4
Morello, G.5
Wieselthaler, G.6
-
21
-
-
12844273500
-
Magnetically suspended centrifugal blood pump with a radial magnetic driver
-
H. Hoshi, K. Katakoa, K. Ohuchi, J. Asama, T. Shinshi, A. Shimokohbe, and S. Takatani, "Magnetically suspended centrifugal blood pump with a radial magnetic driver," ASAIO J., vol. 51, no. 1, pp. 60-64, 2005.
-
(2005)
ASAIO J
, vol.51
, Issue.1
, pp. 60-64
-
-
Hoshi, H.1
Katakoa, K.2
Ohuchi, K.3
Asama, J.4
Shinshi, T.5
Shimokohbe, A.6
Takatani, S.7
-
22
-
-
27744605262
-
Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance
-
A. Untaroiu, A. L. Throckmorton, S. M. Patel, H. G. Wood, P. E. Allaire, and D. B. Olsen, "Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance," Artif. Organs, vol. 29, no. 7, pp. 581-591, 2005.
-
(2005)
Artif. Organs
, vol.29
, Issue.7
, pp. 581-591
-
-
Untaroiu, A.1
Throckmorton, A.L.2
Patel, S.M.3
Wood, H.G.4
Allaire, P.E.5
Olsen, D.B.6
-
23
-
-
4544362831
-
Transient and quasi-steady computational fluid dynamics study of a left ventricular assist device
-
X. Song, A. L. Throckmorton, H. G. Wood, P. E. Allaire, and D. B. Olsen, "Transient and quasi-steady computational fluid dynamics study of a left ventricular assist device," ASAIO J., vol. 50, no. 5, pp. 410-417, 2004.
-
(2004)
ASAIO J
, vol.50
, Issue.5
, pp. 410-417
-
-
Song, X.1
Throckmorton, A.L.2
Wood, H.G.3
Allaire, P.E.4
Olsen, D.B.5
-
24
-
-
12844273500
-
Magnetically suspended centrifugal blood pump with a radial magnetic driver
-
H. Hoshi, K. Katakoa, K. Ohuchi, J. Asama, T. Shinshi, A. Shimokohbe, and S. Takatani, "Magnetically suspended centrifugal blood pump with a radial magnetic driver," ASAIO J., vol. 51, no. 1, pp. 60-64, 2005.
-
(2005)
ASAIO J
, vol.51
, Issue.1
, pp. 60-64
-
-
Hoshi, H.1
Katakoa, K.2
Ohuchi, K.3
Asama, J.4
Shinshi, T.5
Shimokohbe, A.6
Takatani, S.7
-
25
-
-
15444379970
-
Magnevad - the world's smallest magnetic-bearing turbo pump
-
M. Goldowsky, "Magnevad - the world's smallest magnetic-bearing turbo pump," Artif. Organs, vol. 28, no. 10, pp. 945-952, 2004.
-
(2004)
Artif. Organs
, vol.28
, Issue.10
, pp. 945-952
-
-
Goldowsky, M.1
-
26
-
-
27644535295
-
Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changes
-
Jul. 15, Epub ahead of print
-
J. Wohlschlaeger, K. J. Schmitz, C. Schmid, K. W. Schmid, P. Keul, A. Takeda, S. Weis, B. Levkau, and H. A. Baba, "Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changes," Cardiovasc. Res., Jul. 15, 2005, Epub ahead of print.
-
(2005)
Cardiovasc. Res
-
-
Wohlschlaeger, J.1
Schmitz, K.J.2
Schmid, C.3
Schmid, K.W.4
Keul, P.5
Takeda, A.6
Weis, S.7
Levkau, B.8
Baba, H.A.9
-
27
-
-
23944456315
-
Physiological control of left ventricular assist devices based on gradient of flow
-
S. Chen, J. F. Antaki, M. A. Simaan, and J. R. Boston, "Physiological control of left ventricular assist devices based on gradient of flow," in Proc. Amer. Control Conf., 2005, pp. 3829-3824.
-
(2005)
Proc. Amer. Control Conf
, pp. 3829-3824
-
-
Chen, S.1
Antaki, J.F.2
Simaan, M.A.3
Boston, J.R.4
-
28
-
-
0037898308
-
Control strategy for maintaining physiological perfusion with rotary blood pumps
-
G. A. Giridharan and M. Skliar, "Control strategy for maintaining physiological perfusion with rotary blood pumps," Artif. Organs, vol. 27, no. 7, pp. 639-648, 2003.
-
(2003)
Artif. Organs
, vol.27
, Issue.7
, pp. 639-648
-
-
Giridharan, G.A.1
Skliar, M.2
-
29
-
-
0027440116
-
Is rapid rise in vascular conductance at onset of dynamic exercise due to muscle pump?
-
D. D. Sheriff, L. B. Rowell, and A. M. Scher, "Is rapid rise in vascular conductance at onset of dynamic exercise due to muscle pump?," Amer. J. Physiol., vol. 265, pp. H1227-H1234, 1993.
-
(1993)
Amer. J. Physiol
, vol.265
-
-
Sheriff, D.D.1
Rowell, L.B.2
Scher, A.M.3
-
30
-
-
85047677885
-
Central venous pressure during exercise: Role of muscle pump
-
C. F. Notarius and S. Magder, "Central venous pressure during exercise: Role of muscle pump," Can. J. Physiol. Pharmacol., vol. 47, pp. 47-651, 1996.
-
(1996)
Can. J. Physiol. Pharmacol
, vol.47
, pp. 47-651
-
-
Notarius, C.F.1
Magder, S.2
-
31
-
-
34047198760
-
Study of pressure estimation for a human circulatory system with a LVAD
-
Y. Wu, P. E. Allaire, G. Tao, and D. B. Olsen, "Study of pressure estimation for a human circulatory system with a LVAD," in Proc. Amer. Control Conf., 2006, pp. 713-718.
-
(2006)
Proc. Amer. Control Conf
, pp. 713-718
-
-
Wu, Y.1
Allaire, P.E.2
Tao, G.3
Olsen, D.B.4
|