-
2
-
-
0033932245
-
The Odyssey of the Artificial Heart
-
DeBakey, M. E., 2000, "The Odyssey of the Artificial Heart," Artif. Organs, 24(6), pp. 405-11.
-
(2000)
Artif. Organs
, vol.24
, Issue.6
, pp. 405-411
-
-
DeBakey, M.E.1
-
3
-
-
0033945443
-
The History of Continuous-Flow Blood Pumps
-
Olsen, D. B., 2000, "The History of Continuous-Flow Blood Pumps," Artif. Organs, 24(6), pp. 401-4.
-
(2000)
Artif. Organs
, vol.24
, Issue.6
, pp. 401-404
-
-
Olsen, D.B.1
-
4
-
-
0042809769
-
Axial Flow Blood Pumps
-
Song, X., Throekmorton, A. L., Untaroiu, A., Patel, S., Allaire, P. E., Wood, H. G., and Olsen, D. B., 2003. "Axial Flow Blood Pumps," ASAIO J., 49, pp. 355-364.
-
(2003)
ASAIO J.
, vol.49
, pp. 355-364
-
-
Song, X.1
Throekmorton, A.L.2
Untaroiu, A.3
Patel, S.4
Allaire, P.E.5
Wood, H.G.6
Olsen, D.B.7
-
5
-
-
0030250486
-
A Design Improvement Strategy for Axial Blood Pumps Using Computational Fluid Dynamics
-
Burgreen, G. W., Antaki, J. F., and Griffith, B. P., 1996, "A Design Improvement Strategy for Axial Blood Pumps Using Computational Fluid Dynamics," ASAIO J., 42, pp. M354-M360.
-
(1996)
ASAIO J.
, vol.42
-
-
Burgreen, G.W.1
Antaki, J.F.2
Griffith, B.P.3
-
6
-
-
0031922692
-
Computational Fluid Dynamic Analyses to Establish Design Process of Centrifugal Blood Pumps
-
Miyazoe, Y., Sawairi, T., Ito, K., Konishi, Y., Yamane, T., Nishida, M., Masuzawa, T., Takiura, K., and Taenaka, Y., "Computational Fluid Dynamic Analyses to Establish Design Process of Centrifugal Blood Pumps," Artif. Organs, 23, pp. 381-385.
-
Artif. Organs
, vol.23
, pp. 381-385
-
-
Miyazoe, Y.1
Sawairi, T.2
Ito, K.3
Konishi, Y.4
Yamane, T.5
Nishida, M.6
Masuzawa, T.7
Takiura, K.8
Taenaka, Y.9
-
7
-
-
0033374362
-
Numerical Solution for Blood Flow in a Centrifugal Assist Device
-
Wood, H. G., Anderson, J. B., Allaire, P. E., McDaniel, J. C., and Bearnson, G., 1999, "Numerical Solution for Blood Flow in a Centrifugal Assist Device." Int. J. Artif. Organs, 22(12), pp. 827-36.
-
(1999)
Int. J. Artif. Organs
, vol.22
, Issue.12
, pp. 827-836
-
-
Wood, H.G.1
Anderson, J.B.2
Allaire, P.E.3
McDaniel, J.C.4
Bearnson, G.5
-
8
-
-
0032865629
-
Blood Flow in a Continuous Flow Ventricular Assist Device
-
Allaire, P. E., Wood, H. G., Awad, R. S., and Olsen, D. B., 1999, "Blood Flow in a Continuous Flow Ventricular Assist Device," Artif. Organs, 27(8), pp. 769-73.
-
(1999)
Artif. Organs
, vol.27
, Issue.8
, pp. 769-773
-
-
Allaire, P.E.1
Wood, H.G.2
Awad, R.S.3
Olsen, D.B.4
-
9
-
-
0034041252
-
Computational Flow Study of the CFVAD3 Blood Pump
-
Anderson, J. B., Wood, H. G., Allaire, P. E., Bearnson, G., and Khanwilkar, P., 2000, "Computational Flow Study of the CFVAD3 Blood Pump," Artif. Organs, 24(5), pp. 377-85.
-
(2000)
Artif. Organs
, vol.24
, Issue.5
, pp. 377-385
-
-
Anderson, J.B.1
Wood, H.G.2
Allaire, P.E.3
Bearnson, G.4
Khanwilkar, P.5
-
10
-
-
12944288246
-
Numerical Studies of Blood Shear and Washing in a Continuous Flow Ventricular Assist Device
-
Anderson, J. B., Wood, H. G., Allaire, P. E., McDaniel, J. C., Olsen, D. B., and Bearnson, G., 2000, "Numerical Studies of Blood Shear and Washing in a Continuous Flow Ventricular Assist Device," ASAIO J., 46(4), pp. 486-94.
-
(2000)
ASAIO J.
, vol.46
, Issue.4
, pp. 486-494
-
-
Anderson, J.B.1
Wood, H.G.2
Allaire, P.E.3
McDaniel, J.C.4
Olsen, D.B.5
Bearnson, G.6
-
11
-
-
0034827843
-
Computational Fluid Dynamics and Experimental Validation of a Microaxial Blood Pump
-
Apel, J., Neuael, F., and Reul, H., 2001, "Computational Fluid Dynamics and Experimental Validation of a Microaxial Blood Pump," ASAIO J., 47(5), pp. 552-8.
-
(2001)
ASAIO J.
, vol.47
, Issue.5
, pp. 552-558
-
-
Apel, J.1
Neuael, F.2
Reul, H.3
-
12
-
-
0036739023
-
Computational Fluid Dynamics Modeling of Impeller Designs for the HeartQuest Left Ventricular Assist Device
-
Curtas, A. R., Wood, H. G., Allaire, P. E., McDaniel, J. C., Day, S. W., and Olsen, D. B., 2002, "Computational Fluid Dynamics Modeling of Impeller Designs for the HeartQuest Left Ventricular Assist Device," ASAIO J., 48(5), pp. 552-61.
-
(2002)
ASAIO J.
, vol.48
, Issue.5
, pp. 552-561
-
-
Curtas, A.R.1
Wood, H.G.2
Allaire, P.E.3
McDaniel, J.C.4
Day, S.W.5
Olsen, D.B.6
-
13
-
-
0030055691
-
Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings
-
Allaire, P. E., Kin, H. C., and Maslen, E. H., 1996, "Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings," Artif. Organs, 20(6), pp. 582-90.
-
(1996)
Artif. Organs
, vol.20
, Issue.6
, pp. 582-590
-
-
Allaire, P.E.1
Kin, H.C.2
Maslen, E.H.3
-
14
-
-
0030054588
-
Using Hybrid Magnetic Bearings to Completely Suspend the Impeller of a Ventricular Assist Device
-
Kanwilkar, P. S., Olsen, D. B., and Beamson, G. B., 1996, "Using Hybrid Magnetic Bearings to Completely Suspend the Impeller of a Ventricular Assist Device," Artif. Organs, 20(6), pp. 597-604.
-
(1996)
Artif. Organs
, vol.20
, Issue.6
, pp. 597-604
-
-
Kanwilkar, P.S.1
Olsen, D.B.2
Beamson, G.B.3
-
15
-
-
0030763210
-
Hypoalbuminemia Causes High Blood Viscosity by Increasing Red Cell Lysophosphatidylcholine
-
Joles, J. A., Willekes-Koolschijn, N., and Koomans, H. A., 1997. "Hypoalbuminemia Causes High Blood Viscosity by Increasing Red Cell Lysophosphatidylcholine," Kidney Int., 52(3), pp. 761-770.
-
(1997)
Kidney Int.
, vol.52
, Issue.3
, pp. 761-770
-
-
Joles, J.A.1
Willekes-Koolschijn, N.2
Koomans, H.A.3
-
16
-
-
0033863339
-
Hematocrit, Volume Expander, Temperature, and Shear Rate Effects on Blood Viscosity
-
Eckmann, D. M., Bowers, S., Stecker, M., and Cheung, A. T., 2000, "Hematocrit, Volume Expander, Temperature, and Shear Rate Effects on Blood Viscosity," Anesth. Analg. (Baltimore), 91(3), pp. 539-545.
-
(2000)
Anesth. Analg. (Baltimore)
, vol.91
, Issue.3
, pp. 539-545
-
-
Eckmann, D.M.1
Bowers, S.2
Stecker, M.3
Cheung, A.T.4
-
17
-
-
0036428688
-
A Prototype HeartQuest™ Ventricular Assist Device for Particle Image Velocimetry Measurements
-
Day, S. W., McDaniel, J. C., Wood, H. G., Allaire, P. E., Song, X., Lemire, P. P., and Miles, S. D., 2002, "A Prototype HeartQuest™ Ventricular Assist Device for Particle Image Velocimetry Measurements," Artif. Organs, 26(11), pp. 1002-1005.
-
(2002)
Artif. Organs
, vol.26
, Issue.11
, pp. 1002-1005
-
-
Day, S.W.1
McDaniel, J.C.2
Wood, H.G.3
Allaire, P.E.4
Song, X.5
Lemire, P.P.6
Miles, S.D.7
-
18
-
-
85121096080
-
Studies of Turbulence Models in a CFD Model of a Blood Pump
-
Song, X., Wood, H. G., Day, S. W., and Olsen, D. B., "Studies of Turbulence Models in a CFD Model of a Blood Pump," Artif. Organs, 27(10), pp. 938-941.
-
Artif. Organs
, vol.27
, Issue.10
, pp. 938-941
-
-
Song, X.1
Wood, H.G.2
Day, S.W.3
Olsen, D.B.4
-
19
-
-
0029090222
-
Model for a General Mechanical Blood Damage Prediction
-
Bludszuweit, C., 1995, "Model for a General Mechanical Blood Damage Prediction," Artif. Organs, 19(7), pp. 583-89.
-
(1995)
Artif. Organs
, vol.19
, Issue.7
, pp. 583-589
-
-
Bludszuweit, C.1
-
20
-
-
0019186014
-
A Couette Viscometer for Short Time Shearing in Blood
-
Heuser, G., and Optiz, R., 1980, "A Couette Viscometer for Short Time Shearing in Blood," Biorheology, 17, pp. 17-24.
-
(1980)
Biorheology
, vol.17
, pp. 17-24
-
-
Heuser, G.1
Optiz, R.2
-
21
-
-
0025082325
-
Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - In vitro Comparison of 25 Aortic Valves
-
Giersicpen, M., Warzinger, L. J., Opitz, R., and Reul, H., 1990, "Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in vitro Comparison of 25 Aortic Valves," Int. J. Artif. Organs, 13(5), pp. 300-306.
-
(1990)
Int. J. Artif. Organs
, vol.13
, Issue.5
, pp. 300-306
-
-
Giersicpen, M.1
Warzinger, L.J.2
Opitz, R.3
Reul, H.4
-
22
-
-
0034837086
-
Assessment of Hemolysis Related Quantities in a Microaxial Blood Pump by Computational Fluid Dynamics
-
Apel, J., Paul, R., Klaus, S., Siess, T., and Reul, H., 2001, "Assessment of Hemolysis Related Quantities in a Microaxial Blood Pump by Computational Fluid Dynamics," Artif. Organs, 25(5), pp. 341-347.
-
(2001)
Artif. Organs
, vol.25
, Issue.5
, pp. 341-347
-
-
Apel, J.1
Paul, R.2
Klaus, S.3
Siess, T.4
Reul, H.5
-
23
-
-
0036046291
-
Numerical Investigation of the Effect of Blade Geometry on Blood Trauma in a Centrifugal Blood Pump
-
Chan, W. K., Wong, Y. W., Ding, Y., Chua, L. P., and Yu, S. C. M., 2002, "Numerical Investigation of the Effect of Blade Geometry on Blood Trauma in a Centrifugal Blood Pump," Artif. Organs, 16(9), pp. 785-793.
-
(2002)
Artif. Organs
, vol.16
, Issue.9
, pp. 785-793
-
-
Chan, W.K.1
Wong, Y.W.2
Ding, Y.3
Chua, L.P.4
Yu, S.C.M.5
-
24
-
-
85121095873
-
CFD Prediction of Blood Damage in a Centrifugal Pump
-
Song, X., Throekmorton, A. L., Wood, H. G., Antaki, J. F., and Olsen, D. B., 2003, "CFD Prediction of Blood Damage in a Centrifugal Pump," Artif. Organs, 27(10), pp. 935-937.
-
(2003)
Artif. Organs
, vol.27
, Issue.10
, pp. 935-937
-
-
Song, X.1
Throekmorton, A.L.2
Wood, H.G.3
Antaki, J.F.4
Olsen, D.B.5
-
26
-
-
0003922258
-
-
McGraw-Hill Publishing Company, New York, NY
-
Karassik I. J., Krutzsch W. C., Fraser W. H., and Messina J. P., 1985. Pump Handbook (Second Edition). McGraw-Hill Publishing Company, New York, NY.
-
(1985)
Pump Handbook (Second Edition)
-
-
Karassik, I.J.1
Krutzsch, W.C.2
Fraser, W.H.3
Messina, J.P.4
-
27
-
-
0016446510
-
Deformation and Fragmentation of Human Red Blood Cells in Turbulent Shear Flow
-
Sutera, S. P., and Mehrjardi, M. H., 1975, "Deformation and Fragmentation of Human Red Blood Cells in Turbulent Shear Flow," Biophys. J., 15, pp. 1-10.
-
(1975)
Biophys. J.
, vol.15
, pp. 1-10
-
-
Sutera, S.P.1
Mehrjardi, M.H.2
-
28
-
-
0034541762
-
Recommendations for Achieving Accurate Numerical Simulation of Tip Clearance Flows in Transonic Compressor Rotors
-
Zante, E. V., Strazisar, A. J., and Wood, J. R., 2000, "Recommendations for Achieving Accurate Numerical Simulation of Tip Clearance Flows in Transonic Compressor Rotors," ASME J. Turbomach., 122, pp. 733-42.
-
(2000)
ASME J. Turbomach.
, vol.122
, pp. 733-742
-
-
Zante, E.V.1
Strazisar, A.J.2
Wood, J.R.3
|