메뉴 건너뛰기




Volumn 3, Issue , 2007, Pages 1950-1953

Development and characterization of CMOS-based monolithic X-ray imager sensor

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG TO DIGITAL CONVERSION; DIGITAL CAMERAS; DIGITAL IMAGE STORAGE; DIGITAL TO ANALOG CONVERSION; DYNAMIC RESPONSE; INTELLIGENT VEHICLE HIGHWAY SYSTEMS; LIGHT EMISSION; LUMINESCENCE; MEDICAL IMAGING; MULTICARRIER MODULATION; NETWORKS (CIRCUITS); PHOTORESISTS; PIXELS; SCINTILLATION; SCINTILLATION COUNTERS; SENSORS; SIGNAL PROCESSING; X RAY ANALYSIS; X RAY APPARATUS; X RAY OPTICS; X RAYS;

EID: 48349142864     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436536     Document Type: Conference Paper
Times cited : (3)

References (7)
  • 1
    • 0034873661 scopus 로고    scopus 로고
    • High resolution CMOS imaging detector
    • Thorsten Graeve and Gene P. Weckler, "High resolution CMOS imaging detector", Proc. SPIE, Vol. 4320, 2001.
    • (2001) Proc. SPIE , vol.4320
    • Graeve, T.1    Weckler, G.P.2
  • 3
    • 33747160408 scopus 로고    scopus 로고
    • Analysis of noise characteristics for the active pixels in CMOS image sensor for X-ray imaging
    • Young Soo Kim, Gyuseong Cho, Jung-Hyung Bac, "Analysis of noise characteristics for the active pixels in CMOS image sensor for X-ray imaging," Nuclear Instruments and Methods in Physics Research A. Vol. 565, pp. 263-267, 2006.
    • (2006) Nuclear Instruments and Methods in Physics Research A , vol.565 , pp. 263-267
    • Young, S.1    Cho, G.2    Bac, J.-H.3
  • 5
    • 23844544080 scopus 로고    scopus 로고
    • A simple edge device method for determining the presampling Modulation Transfer Function (MTF) of Flat Field Digital Detectors
    • B. Wang, K. Barner, D. Lee, B. Rodricks, and C. Liu, "A simple edge device method for determining the presampling Modulation Transfer Function (MTF) of Flat Field Digital Detectors," Proc. of SPIE vol.5745 pp. 1191-1198, 2005.
    • (2005) Proc. of SPIE , vol.5745 , pp. 1191-1198
    • Wang, B.1    Barner, K.2    Lee, D.3    Rodricks, B.4    Liu, C.5
  • 6
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • January
    • Ehsan Samei, Michael J. Flynn, David A. Reimann, "A method for measuring the presampled MTF of digital radiographic systems using an edge test device," Med. Phys. 25 (1), pp. 102-113, January 1998.
    • (1998) Med. Phys , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.