메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3260-3267

Fully 4D image reconstruction by estimation of an input function and spectral coefficients

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE PROCESSING; IMAGE RECONSTRUCTION; MEDICAL IMAGING; POSITRON EMISSION TOMOGRAPHY; PROBABILITY DENSITY FUNCTION; REPAIR; RESTORATION; SPECTRUM ANALYSIS; SPECTRUM ANALYZERS;

EID: 48349134942     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436834     Document Type: Conference Paper
Times cited : (48)

References (10)
  • 1
    • 0035017354 scopus 로고    scopus 로고
    • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior
    • D. J. Kadrinas, and G. T. Gullberg, "4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior" Phys. Med. Biol. vol. 46 pp. 1553-74, 2001.
    • (2001) Phys. Med. Biol , vol.46 , pp. 1553-1574
    • Kadrinas, D.J.1    Gullberg, G.T.2
  • 2
    • 0036525894 scopus 로고    scopus 로고
    • Spatiotemporal reconstruction of list-mode PET data
    • T. E. Nichols, J. Qi, E. Asma, and R. M. Leahy, "Spatiotemporal reconstruction of list-mode PET data," IEEE Trans. Med. Imaging vol. 21 pp. 396-404, 2002.
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 396-404
    • Nichols, T.E.1    Qi, J.2    Asma, E.3    Leahy, R.M.4
  • 3
    • 18844431381 scopus 로고    scopus 로고
    • M. E. Kamasak, C. A. Bouman, E. D. Morris, and K. Sauer K, Direct reconstruction of kinetic parameter images from dynamic PET data, IEEE Trans. Med. Imaging 24 pp. 636-50, 2005.
    • M. E. Kamasak, C. A. Bouman, E. D. Morris, and K. Sauer K, "Direct reconstruction of kinetic parameter images from dynamic PET data," IEEE Trans. Med. Imaging vol. 24 pp. 636-50, 2005.
  • 4
  • 6
    • 0021405275 scopus 로고
    • Parameter estimation for dynamic studies in emission-tomography systems having list-mode data
    • D. L. Snyder, "Parameter estimation for dynamic studies in emission-tomography systems having list-mode data" IEEE Trans. Nucl. Sci. vol. 31 pp. 925-31, 1984.
    • (1984) IEEE Trans. Nucl. Sci , vol.31 , pp. 925-931
    • Snyder, D.L.1
  • 7
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi "Maximum likelihood reconstruction for emission tomography" IEEE Trans. Med. Imaging, vol. 1, pp.113-122, 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 8
    • 34247203132 scopus 로고    scopus 로고
    • Performance evaluation of the ECAT HRRT: An LSO-LYSO double layer high resolution, high sensitivity scanner
    • H. W. A. M. de Jong, F. H. P. van Velden, R. W. Kloet, F. L. Buijs, R. Boellaard and A. A. Lammertsma, "Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner," Phys. Med. Biol. vol. 52 pp. 1505-1526, 2002.
    • (2002) Phys. Med. Biol , vol.52 , pp. 1505-1526
    • de Jong, H.W.A.M.1    van Velden, F.H.P.2    Kloet, R.W.3    Buijs, F.L.4    Boellaard, R.5    Lammertsma, A.A.6
  • 9
    • 0034971675 scopus 로고    scopus 로고
    • A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET
    • S. R. Golish, J. D. Hove, H. R. Schelbert, and S. S. Gambhir, "A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET," J. Nucl. Med. vol. 42 no 6 pp. 924-931, 2001.
    • (2001) J. Nucl. Med , vol.42 , Issue.6 , pp. 924-931
    • Golish, S.R.1    Hove, J.D.2    Schelbert, H.R.3    Gambhir, S.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.