메뉴 건너뛰기




Volumn 43, Issue 3, 1998, Pages 651-666

Parametric image reconstruction using spectral analysis of PET projection data

Author keywords

[No Author keywords available]

Indexed keywords

THYMIDINE DERIVATIVE;

EID: 0031881781     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/3/016     Document Type: Article
Times cited : (75)

References (39)
  • 2
    • 0028216170 scopus 로고
    • A convolution-subtraction scatter correction method for 3D PET
    • Bailey D L and Meilde S R 1994 A convolution-subtraction scatter correction method for 3D PET Phys. Med. Biol. 39 411-24
    • (1994) Phys. Med. Biol. , vol.39 , pp. 411-424
    • Bailey, D.L.1    Meilde, S.R.2
  • 4
    • 0021685408 scopus 로고
    • On the construction of functional maps in positron emission tomography
    • Blomqvist G 1984 On the construction of functional maps in positron emission tomography J. Cereb. Blood Flow Metab. 4 629-32
    • (1984) J. Cereb. Blood Flow Metab. , vol.4 , pp. 629-632
    • Blomqvist, G.1
  • 6
    • 0022601993 scopus 로고
    • Weighted integration method for local cerebral blood flow measurements with positron emission tomography
    • Carson R E, Huang S C and Green M V 1986 Weighted integration method for local cerebral blood flow measurements with positron emission tomography J. Cereb. Blood Flow Metab. 6 245-58
    • (1986) J. Cereb. Blood Flow Metab. , vol.6 , pp. 245-258
    • Carson, R.E.1    Huang, S.C.2    Green, M.V.3
  • 7
    • 84950446492 scopus 로고
    • The EM parametric image reconstruction algorithm
    • Carson R E and Lange K 1985 The EM parametric image reconstruction algorithm J. Am. Statist. Assoc. 80 20-2
    • (1985) J. Am. Statist. Assoc. , vol.80 , pp. 20-22
    • Carson, R.E.1    Lange, K.2
  • 12
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • Daube-Witherspoon M E and Muehllehner G 1987 Treatment of axial data in three-dimensional PET J. Nucl. Med. 28 1717-24
    • (1987) J. Nucl. Med. , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 13
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image reconstruction for positron emission tomography
    • Fessler J A 1994 Penalized weighted least-squares image reconstruction for positron emission tomography IEEE Trans. Med. Imaging 13 290-300
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 290-300
    • Fessler, J.A.1
  • 15
    • 0020063566 scopus 로고
    • Measurement of local blood flow and distribution volume with short-lived isotopes: A general input technique
    • Huang S C, Carson R E and Phelps M E 1982 Measurement of local blood flow and distribution volume with short-lived isotopes: a general input technique J. Cereb. Blood Flow Metab. 2 99-108
    • (1982) J. Cereb. Blood Flow Metab. , vol.2 , pp. 99-108
    • Huang, S.C.1    Carson, R.E.2    Phelps, M.E.3
  • 16
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H M and Larkin R S 1994 Accelerated image reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 18
    • 0029269576 scopus 로고
    • Effect of real-time calculation of functional images in clinical positron emission tomography
    • Iida H, Bloomfield P M and Yamamoto S 1995 Effect of real-time calculation of functional images in clinical positron emission tomography IEEE Trans. Med. Imaging 14 116
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 116
    • Iida, H.1    Bloomfield, P.M.2    Yamamoto, S.3
  • 20
    • 0026710874 scopus 로고
    • SPECT of rapidly cleared tracers: Imaging a Cheshire cat
    • Juni J E 1992 SPECT of rapidly cleared tracers: imaging a Cheshire cat (editorial) J. Nucl. Med. 33 1206-8
    • (1992) J. Nucl. Med. , vol.33 , pp. 1206-1208
    • Juni, J.E.1
  • 21
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K and Carson R 1984 EM reconstruction algorithms for emission and transmission tomography J. Comput. Assist. Tomogr. 8 306-16
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 23
    • 2642702631 scopus 로고    scopus 로고
    • Patlak analysis applied to sinogram data
    • ed R Myers, V Cunningham, D Bailey and T Jones (San Diego: Academic)
    • Maguire R P, Calender C and Leenders K L 1996 Patlak analysis applied to sinogram data Quantification of Brain Function Using PET ed R Myers, V Cunningham, D Bailey and T Jones (San Diego: Academic) pp 307-11
    • (1996) Quantification of Brain Function Using PET , pp. 307-311
    • Maguire, R.P.1    Calender, C.2    Leenders, K.L.3
  • 24
    • 0030956911 scopus 로고    scopus 로고
    • The direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction
    • Matthews J C, Ashburner A, Bailey D, Harte R, Price P and Jones T 1997 The direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction Phys. Med. Biol. 42 1155-73
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1155-1173
    • Matthews, J.C.1    Ashburner, A.2    Bailey, D.3    Harte, R.4    Price, P.5    Jones, T.6
  • 26
    • 0027934281 scopus 로고
    • Accelerated EM reconstruction in total body PET: Potential for improving tumour detectability
    • Meikle S R, Hutton B F, Bailey D L, Hooper P K and Fulham M J 1994 Accelerated EM reconstruction in total body PET: potential for improving tumour detectability Phys. Med. Biol. 39 1689-704
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1689-1704
    • Meikle, S.R.1    Hutton, B.F.2    Bailey, D.L.3    Hooper, P.K.4    Fulham, M.J.5
  • 30
    • 0026328315 scopus 로고
    • The on-line monitoring of continuously withdrawn arterial blood during PET studies using a single BGO/photomultiplier assembly and non-stick tubing
    • Ranicar A S O, Williams C W, Schnorr L, Clark J C, Rhodes C G, Bloomfield P M and Jones T 1991 The on-line monitoring of continuously withdrawn arterial blood during PET studies using a single BGO/photomultiplier assembly and non-stick tubing Med. Prog. Through Technol. 17 259-64
    • (1991) Med. Prog. Through Technol. , vol.17 , pp. 259-264
    • Ranicar, A.S.O.1    Williams, C.W.2    Schnorr, L.3    Clark, J.C.4    Rhodes, C.G.5    Bloomfield, P.M.6    Jones, T.7
  • 31
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L A and Vardi Y 1982 Maximum likelihood reconstruction for emission tomography IEEE Trans. Med. Imaging 1 113-22
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 32
    • 0021405275 scopus 로고
    • Parameter estimation for dynamic studies in emission-tomography systems having list-mode data
    • Snyder D L 1984 Parameter estimation for dynamic studies in emission-tomography systems having list-mode data IEEE Trans. Nucl. Sci. 31 925-31
    • (1984) IEEE Trans. Nucl. Sci. , vol.31 , pp. 925-931
    • Snyder, D.L.1
  • 33
    • 0023605735 scopus 로고
    • Antitumour activity and pharmacokinetics in mice of 8-carbamoyl-3-methyl-imidazo [5,1-d]-1,2,3,5-tetrazin-4 (3H)-one (CCRG 91045; M&B 39831), a novel drug with potential as an alternative to dacarbazine
    • Stevens M F G, Hickman J A and Langdon S P 1987 Antitumour activity and pharmacokinetics in mice of 8-carbamoyl-3-methyl-imidazo [5,1-d]-1,2,3,5-tetrazin-4 (3H)-one (CCRG 91045; M&B 39831), a novel drug with potential as an alternative to dacarbazine Cancer Res. 47 5846-52
    • (1987) Cancer Res. , vol.47 , pp. 5846-5852
    • Stevens, M.F.G.1    Hickman, J.A.2    Langdon, S.P.3
  • 35
    • 0018142166 scopus 로고
    • Transverse section imaging of mean clearance time
    • Tsui E and Budinger T F 1978 Transverse section imaging of mean clearance time Phys. Med. Biol. 23 644-53
    • (1978) Phys. Med. Biol. , vol.23 , pp. 644-653
    • Tsui, E.1    Budinger, T.F.2
  • 36
    • 0029928294 scopus 로고    scopus 로고
    • Positron emission tomography: A new investigational area for cancer research
    • Wells P, Harte R J A and Price P 1996 Positron emission tomography: a new investigational area for cancer research Clin. Oncol. 8 7-14
    • (1996) Clin. Oncol. , vol.8 , pp. 7-14
    • Wells, P.1    Harte, R.J.A.2    Price, P.3
  • 37
    • 0027649005 scopus 로고
    • Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images
    • Wilson D W and Tsui B M W 1993 Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images IEEE Trans. Nucl. Sci. 40 1198-203
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1198-1203
    • Wilson, D.W.1    Tsui, B.M.W.2
  • 38
    • 0028309681 scopus 로고
    • Noise properties of the EM algorithm: II Monte Carlo simulations
    • Wilson D W, Tsui B M W and Barrett H H 1994 Noise properties of the EM algorithm: II Monte Carlo simulations Phys. Med. Biol. 39 847-71
    • (1994) Phys. Med. Biol. , vol.39 , pp. 847-871
    • Wilson, D.W.1    Tsui, B.M.W.2    Barrett, H.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.