메뉴 건너뛰기




Volumn 16, Issue 2, 2008, Pages 95-117

Application of projection simulation based on physical imaging model to the evaluation of beam hardening corrections in X-ray transmission tomography

Author keywords

Beam hardening; FORBILD; Polychromatic spectrum; Projection simulation

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; ELECTRON TUBES; HARDENING; HEALTH; IMAGING TECHNIQUES; MEDICAL IMAGING; PLASMA DIAGNOSTICS; RADIOGRAPHY; TOMOGRAPHY; X RAY TUBES;

EID: 48249139023     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (27)

References (35)
  • 1
    • 0017367936 scopus 로고
    • Correction for spectral artifacts in cross-sectional reconstruction for X-rays
    • W.D. McDavid, R.G. Waggener, W.H. Payne and M.J. Dennis, Correction for spectral artifacts in cross-sectional reconstruction for X-rays, Med Phys 4(1) (1977), 54-57.
    • (1977) Med Phys , vol.4 , Issue.1 , pp. 54-57
    • McDavid, W.D.1    Waggener, R.G.2    Payne, W.H.3    Dennis, M.J.4
  • 2
    • 0017810277 scopus 로고    scopus 로고
    • M.J. Peter and D.S. Robin, A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners, J Computer Assisted Tomography 2 (1978), 100-108.
    • M.J. Peter and D.S. Robin, A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners, J Computer Assisted Tomography 2 (1978), 100-108.
  • 3
    • 33646460131 scopus 로고    scopus 로고
    • Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography
    • K. Marc, S. Katia and A.K. Willi, Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography, Med Phys 33(5) (2006), 1269-1274.
    • (2006) Med Phys , vol.33 , Issue.5 , pp. 1269-1274
    • Marc, K.1    Katia, S.2    Willi, A.K.3
  • 5
    • 48249142226 scopus 로고    scopus 로고
    • Z.W. Henry, How to Read a Head CT, 1999. Available from: http://www.urmc.rochester.edu/smd/Rad/headct.htm.
    • Z.W. Henry, How to Read a Head CT, 1999. Available from: http://www.urmc.rochester.edu/smd/Rad/headct.htm.
  • 7
    • 33750699990 scopus 로고    scopus 로고
    • Comparison on beam hardening correction of CT-based HL consistency and normal water phantom experiment
    • X. Mou, S. Tang and H. Yu, Comparison on beam hardening correction of CT-based HL consistency and normal water phantom experiment, SPIE 6318 (2006), 63181V.
    • (2006) SPIE , vol.6318
    • Mou, X.1    Tang, S.2    Yu, H.3
  • 8
    • 33750721689 scopus 로고    scopus 로고
    • A beam hardening correction method with HL consistency
    • X. Mou, S. Tang and H. Yu, A beam hardening correction method with HL consistency, SPIE 6318 (2006), 63181U.
    • (2006) SPIE , vol.6318
    • Mou, X.1    Tang, S.2    Yu, H.3
  • 9
    • 48249158091 scopus 로고    scopus 로고
    • G. Lauritsch and H. Bruder, head phantom, 1998. Available from: http://www.imp.uni-erlangen.de/phantoms/head/head. html.
    • G. Lauritsch and H. Bruder, head phantom, 1998. Available from: http://www.imp.uni-erlangen.de/phantoms/head/head. html.
  • 10
    • 0033983759 scopus 로고    scopus 로고
    • Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
    • S. Wilfried, B. Thomas and S. Wolfgang, Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions, Phys Med Biol 45(2) (2000), 459-478.
    • (2000) Phys Med Biol , vol.45 , Issue.2 , pp. 459-478
    • Wilfried, S.1    Thomas, B.2    Wolfgang, S.3
  • 11
    • 33748478895 scopus 로고    scopus 로고
    • Generalized Algorithm for X-Ray Projections Generation in Cone-Beam Tomography
    • Z. Qin, X. Mou, P. Wang, Y. Cai and C. Hou, Generalized Algorithm for X-Ray Projections Generation in Cone-Beam Tomography, JXi'an Jiaotong Univ 36(2) (2002), 160-164.
    • (2002) JXi'an Jiaotong Univ , vol.36 , Issue.2 , pp. 160-164
    • Qin, Z.1    Mou, X.2    Wang, P.3    Cai, Y.4    Hou, C.5
  • 12
    • 0033321436 scopus 로고    scopus 로고
    • Metal Streak Artifacts in X-ray Computed Tomography: A Simulation Study
    • B. De Man, J. Nuyts, P. Dupont, G. Marchal and P. Suetens, Metal Streak Artifacts in X-ray Computed Tomography: A Simulation Study, IEEE Trans Nucl Sci 46(3) (1999), 691-696.
    • (1999) IEEE Trans Nucl Sci , vol.46 , Issue.3 , pp. 691-696
    • De Man, B.1    Nuyts, J.2    Dupont, P.3    Marchal, G.4    Suetens, P.5
  • 14
    • 33748485641 scopus 로고    scopus 로고
    • X-ray projection simulation based on physical imaging model
    • S. Tang, H. Yu, H. Yan, B. Deepak and X. Mou, X-ray projection simulation based on physical imaging model, J X-Ray Sci Technol 14 (2006), 177-189.
    • (2006) J X-Ray Sci Technol , vol.14 , pp. 177-189
    • Tang, S.1    Yu, H.2    Yan, H.3    Deepak, B.4    Mou, X.5
  • 15
    • 33748517506 scopus 로고    scopus 로고
    • Available from
    • A.F. Bielajew et al., Electron Gamma Shower, 2001. Available from: http://www.slac.stanford.edu/egs/egs4_source.html.
    • (2001) Electron Gamma Shower
    • Bielajew, A.F.1
  • 18
    • 27244447259 scopus 로고    scopus 로고
    • Computed tomography simulation with superquadrics
    • J. Zhu, S. Zhao, Y. Ye and G. Wang, Computed tomography simulation with superquadrics, Med Phys 32(10) (2005), 3136-3143.
    • (2005) Med Phys , vol.32 , Issue.10 , pp. 3136-3143
    • Zhu, J.1    Zhao, S.2    Ye, Y.3    Wang, G.4
  • 19
    • 33750719432 scopus 로고    scopus 로고
    • Analytic simulation scheme for x-ray projections based on Physics Model
    • S. Tang, H. Yu and X. Mou, Analytic simulation scheme for x-ray projections based on Physics Model, SPIE 6318 (2006), 63181T.
    • (2006) SPIE , vol.6318
    • Tang, S.1    Yu, H.2    Mou, X.3
  • 20
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in X-ray computerized tomography
    • R.E. Alvarez and A. Macovski, Energy-selective reconstructions in X-ray computerized tomography, Phys Med Biol 21(5) (1976), 733-744.
    • (1976) Phys Med Biol , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    Macovski, A.2
  • 21
    • 29144515780 scopus 로고    scopus 로고
    • Beam hardening artifacts in computed tomography with photon counting, charge integrating and energy weighting detectors: A simulation study
    • P.M. Shikhaliev, Beam hardening artifacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study, Phys Med Biol 50(24) (2005), 5813-5827.
    • (2005) Phys Med Biol , vol.50 , Issue.24 , pp. 5813-5827
    • Shikhaliev, P.M.1
  • 22
    • 3042824019 scopus 로고    scopus 로고
    • Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods
    • E.Y Sidky, Y Zou and X. Pan, Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods, Phys Med Biol 49(11) (2004), 2293-2303.
    • (2004) Phys Med Biol , vol.49 , Issue.11 , pp. 2293-2303
    • Sidky, E.Y.1    Zou, Y.2    Pan, X.3
  • 23
    • 34547137886 scopus 로고    scopus 로고
    • K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    • E. Roessl and R. Proksa, K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors, Phys Med Biol 52(15) (2007), 4679-4696.
    • (2007) Phys Med Biol , vol.52 , Issue.15 , pp. 4679-4696
    • Roessl, E.1    Proksa, R.2
  • 25
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 keV
    • J.M. Boone and J.A. Seibert, An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 keV, Med Phys 24(11) (1997), 1661-1670.
    • (1997) Med Phys , vol.24 , Issue.11 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 26
    • 0021075243 scopus 로고
    • Absorption and noise in cesium iodide x-ray image intensifies
    • J.A. Rowlands and K.M. Taylor, Absorption and noise in cesium iodide x-ray image intensifies, Med Phys 10(6) (1983), 786-795.
    • (1983) Med Phys , vol.10 , Issue.6 , pp. 786-795
    • Rowlands, J.A.1    Taylor, K.M.2
  • 27
    • 0027659307 scopus 로고    scopus 로고
    • G. Wang, T. Lin, P. Cheng and D.M. Shinozaki, A General Cone-Beam Reconstruction Algorithm, IEEE Trans Med Imaging 12(3) (1993), 486-496.
    • G. Wang, T. Lin, P. Cheng and D.M. Shinozaki, A General Cone-Beam Reconstruction Algorithm, IEEE Trans Med Imaging 12(3) (1993), 486-496.
  • 28
    • 28644446445 scopus 로고    scopus 로고
    • A differentiable Shepp-Logan phantom and its applications in exact cone-beam CT
    • H. Yu, S. Zhao and G. Wang, A differentiable Shepp-Logan phantom and its applications in exact cone-beam CT, Phys Med Biol 50(23) (2005), 5583-5595.
    • (2005) Phys Med Biol , vol.50 , Issue.23 , pp. 5583-5595
    • Yu, H.1    Zhao, S.2    Wang, G.3
  • 29
    • 0025478201 scopus 로고
    • CT Image Correction for Beam hardening Using Simulated Projection Data
    • J.M. Meagher, C.D. Mote, Jr. and H.B. Skinner, CT Image Correction for Beam hardening Using Simulated Projection Data, IEEE Transaction on Nuclear Science 37(4) (1990), 1520-1524.
    • (1990) IEEE Transaction on Nuclear Science , vol.37 , Issue.4 , pp. 1520-1524
    • Meagher, J.M.1    Mote Jr., C.D.2    Skinner, H.B.3
  • 30
    • 37549022285 scopus 로고    scopus 로고
    • Feldkamp-type reconstruction algorithms for spiral cone-beam CT with variable pitch
    • J. Zhao, Y. Lu, Y Jin, E. Bai and G. Wang, Feldkamp-type reconstruction algorithms for spiral cone-beam CT with variable pitch, J X-Ray Sci Technol 15(4) (2007), 177-196.
    • (2007) J X-Ray Sci Technol , vol.15 , Issue.4 , pp. 177-196
    • Zhao, J.1    Lu, Y.2    Jin, Y.3    Bai, E.4    Wang, G.5
  • 31
    • 34848882265 scopus 로고    scopus 로고
    • Numerical studies on Palamodov and Generalized Feldkamp algorithm for general cone-beam scanning
    • K. Zeng, H. Yu, E. Bai and G. Wang, Numerical studies on Palamodov and Generalized Feldkamp algorithm for general cone-beam scanning, J X-Ray Sci Technol 15(3) (2007), 131-146.
    • (2007) J X-Ray Sci Technol , vol.15 , Issue.3 , pp. 131-146
    • Zeng, K.1    Yu, H.2    Bai, E.3    Wang, G.4
  • 32
    • 34848907495 scopus 로고    scopus 로고
    • A free-geometry cone beam CT and its FDK-type reconstruction
    • Y Xing and L. Zhang, A free-geometry cone beam CT and its FDK-type reconstruction, J X-Ray Sci Technol 15(3) (2007), 157-167.
    • (2007) J X-Ray Sci Technol , vol.15 , Issue.3 , pp. 157-167
    • Xing, Y.1    Zhang, L.2
  • 33
    • 33845546227 scopus 로고    scopus 로고
    • The FDK algorithm with an expanded definition domain for cone-beam reconstruction preserving oblique line integrals
    • L. Li, K. Kang, Z. Chen, L. Zhang, Y Xing and G. Wang, The FDK algorithm with an expanded definition domain for cone-beam reconstruction preserving oblique line integrals, J X-Ray Sci Technol 14(4) (2006), 217-233.
    • (2006) J X-Ray Sci Technol , vol.14 , Issue.4 , pp. 217-233
    • Li, L.1    Kang, K.2    Chen, Z.3    Zhang, L.4    Xing, Y.5    Wang, G.6
  • 34
  • 35
    • 36348953705 scopus 로고    scopus 로고
    • A polychromatic method to enhance the soft tissue contrast of computerized tomographic images using a saddle point approximation
    • I.S. Walimuni, D.J. Kouri, M. Papadakis and B.G. Bodmann, A polychromatic method to enhance the soft tissue contrast of computerized tomographic images using a saddle point approximation, IEEE ISBI (2007), 828-831.
    • (2007) IEEE ISBI , pp. 828-831
    • Walimuni, I.S.1    Kouri, D.J.2    Papadakis, M.3    Bodmann, B.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.