메뉴 건너뛰기




Volumn 15, Issue 4, 2007, Pages 177-196

Feldkamp-type reconstruction algorithms for spiral cone-beam CT with variable pitch

Author keywords

Approximate image reconstruction; Computed tomographic angiography (CTA); Computed tomography (CT); Cone beam; Feldkamp type algorithms; Helical scanning; Variable pitch

Indexed keywords

ANGIOGRAPHY; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; IMAGE RECONSTRUCTION;

EID: 37549022285     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (38)
  • 1
    • 0344579633 scopus 로고    scopus 로고
    • Bolus-chasing angiography with adaptive real-time computed tomography,
    • U.S. Patent 6,535,821, allowed on 11/26/2002, issued on 3/18/2003
    • G. Wang and M.W. Vannier, Bolus-chasing angiography with adaptive real-time computed tomography, U.S. Patent 6,535,821, allowed on 11/26/2002, issued on 3/18/2003.
    • Wang, G.1    Vannier, M.W.2
  • 2
    • 1642277731 scopus 로고    scopus 로고
    • Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch
    • Y. Ye, J. Zhu and G. Wang, Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch, Med Phys 31 (2004), 566-572.
    • (2004) Med Phys , vol.31 , pp. 566-572
    • Ye, Y.1    Zhu, J.2    Wang, G.3
  • 3
    • 4344623541 scopus 로고    scopus 로고
    • Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography
    • A. Katsevich, S. Basu and J. Hsieh, "Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography, Phys Med Biol 49 (2004), 3089-3103.
    • (2004) Phys Med Biol , vol.49 , pp. 3089-3103
    • Katsevich, A.1    Basu, S.2    Hsieh, J.3
  • 4
    • 23944432358 scopus 로고    scopus 로고
    • PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch
    • Y. Zou, X. Pan, D. Xia and G. Wang, PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch, Med Phys 32 (2005), 2639-2648.
    • (2005) Med Phys , vol.32 , pp. 2639-2648
    • Zou, Y.1    Pan, X.2    Xia, D.3    Wang, G.4
  • 6
    • 0027659307 scopus 로고
    • A general cone-beam reconstruction algorithm
    • G. Wang, T.-H. Lin, and P.C. Cheng, A general cone-beam reconstruction algorithm, IEEE Trans Med Imaging 12 (1993), 486-496.
    • (1993) IEEE Trans Med Imaging , vol.12 , pp. 486-496
    • Wang, G.1    Lin, T.-H.2    Cheng, P.C.3
  • 7
    • 28044434400 scopus 로고    scopus 로고
    • Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT
    • M. Yan and C. Zhang, Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT, Med Phys 32 (2005), 3455-3467.
    • (2005) Med Phys , vol.32 , pp. 3455-3467
    • Yan, M.1    Zhang, C.2
  • 8
    • 33645511679 scopus 로고    scopus 로고
    • A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT - helical scanning
    • X. Tang, J., R.A. Nilsen, S. Dutta, D. Samsonov and A. Hagiwara, A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT - helical scanning, Phys Med Biol 51 (2006), 855-874.
    • (2006) Phys Med Biol , vol.51 , pp. 855-874
    • Tang, X.1    Nilsen, J.R.A.2    Dutta, S.3    Samsonov, D.4    Hagiwara, A.5
  • 9
    • 0041458313 scopus 로고    scopus 로고
    • Development of advanced multislice CT scanner Aquilion
    • I. Mori and T. Suzuki, Development of advanced multislice CT scanner Aquilion, Med Rev 78 (2001), 1-7.
    • (2001) Med Rev , vol.78 , pp. 1-7
    • Mori, I.1    Suzuki, T.2
  • 10
    • 0346994901 scopus 로고    scopus 로고
    • Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT
    • I. Hein, K. Taguchi, M.D. Silver, M. Kazama and I. Mori, Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT, Med Phys 30 (2003), 3233-3242.
    • (2003) Med Phys , vol.30 , pp. 3233-3242
    • Hein, I.1    Taguchi, K.2    Silver, M.D.3    Kazama, M.4    Mori, I.5
  • 11
    • 3042781835 scopus 로고    scopus 로고
    • A new weighting scheme for cone-beam helical CT to reduce the image noise
    • K. Taguchi, B.S. Chiang and M.D. Silver, A new weighting scheme for cone-beam helical CT to reduce the image noise, Phys Med Biol 49 (2004), 2351-2364.
    • (2004) Phys Med Biol , vol.49 , pp. 2351-2364
    • Taguchi, K.1    Chiang, B.S.2    Silver, M.D.3
  • 13
    • 21144453391 scopus 로고    scopus 로고
    • An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition
    • J. Hu, K. Tam, and J. Qi, An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition, Med Phys 32 (2005), 1529-1536.
    • (2005) Med Phys , vol.32 , pp. 1529-1536
    • Hu, J.1    Tam, K.2    Qi, J.3
  • 14
    • 3042640696 scopus 로고    scopus 로고
    • Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage
    • K. Kachelrieß, M. Knaup and W.A. Kalender, Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage, Med Phys 31 (2004), 1623-1641.
    • (2004) Med Phys , vol.31 , pp. 1623-1641
    • Kachelrieß, K.1    Knaup, M.2    Kalender, W.A.3
  • 15
    • 0034917860 scopus 로고    scopus 로고
    • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources
    • Y. Liu, H. Liu, Y. Wang and G. Wang, Half-scan cone-beam CT fluoroscopy with multiple x-ray sources, Med Phys 28 (2001), 1466-1471.
    • (2001) Med Phys , vol.28 , pp. 1466-1471
    • Liu, Y.1    Liu, H.2    Wang, Y.3    Wang, G.4
  • 16
    • 0020030616 scopus 로고
    • Optimal short scan convolution reconstruction for fan beam CT
    • D.L. Parker, Optimal short scan convolution reconstruction for fan beam CT, Med Phys 9 (1982), 254-257.
    • (1982) Med Phys , vol.9 , pp. 254-257
    • Parker, D.L.1
  • 17
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • CR. Crawford and K.F. King, Computed tomography scanning with simultaneous patient translation, Med Phys 17 (1990), 967-982.
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 18
    • 0030023427 scopus 로고    scopus 로고
    • A general approach to the reconstruction of x-ray helical computed tomography
    • J. Hsieh, A general approach to the reconstruction of x-ray helical computed tomography, Med Phys 23 (1996), 221-229.
    • (1996) Med Phys , vol.23 , pp. 221-229
    • Hsieh, J.1
  • 19
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multislice helical CT
    • K. Taguchi and H. Aradate, Algorithm for image reconstruction in multislice helical CT, Med Phys 25 (1998), 550-561.
    • (1998) Med Phys , vol.25 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 20
    • 0032924568 scopus 로고    scopus 로고
    • Multislice helical CT: Scan and reconstruction
    • H. Hu, Multislice helical CT: scan and reconstruction, Med Phys 26 (1999), 5-18.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 21
    • 0033993737 scopus 로고    scopus 로고
    • A method for including redundant data in computed tomography
    • M.D. Silver, A method for including redundant data in computed tomography, Med Phys 27 (2000), 773-774.
    • (2000) Med Phys , vol.27 , pp. 773-774
    • Silver, M.D.1
  • 22
    • 0034257867 scopus 로고    scopus 로고
    • Feldkamp-type cone-beam tomography in the wavelet framework
    • S. Zhao and G. Wang, Feldkamp-type cone-beam tomography in the wavelet framework, IEEE Trans Med Imaging 19 (2000), 922-929.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 922-929
    • Zhao, S.1    Wang, G.2
  • 23
    • 2442661205 scopus 로고    scopus 로고
    • An improved exact filtered backprojection algorithm for spiral computed tomography
    • A. Katsevich, An improved exact filtered backprojection algorithm for spiral computed tomography, Adv Appl Math 32 (2004), 681-697.
    • (2004) Adv Appl Math , vol.32 , pp. 681-697
    • Katsevich, A.1
  • 24
    • 1642569142 scopus 로고    scopus 로고
    • Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    • Y. Zou and X. Pan, Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT, Phys Med Biol 49 (2004), 941-959.
    • (2004) Phys Med Biol , vol.49 , pp. 941-959
    • Zou, Y.1    Pan, X.2
  • 25
    • 0042903710 scopus 로고    scopus 로고
    • A general scheme for constructing inversion algorithms for cone beam CT
    • A. Katsevich, A general scheme for constructing inversion algorithms for cone beam CT, Int J Math Math Sci 21 (2003), 1305-1321.
    • (2003) Int J Math Math Sci , vol.21 , pp. 1305-1321
    • Katsevich, A.1
  • 26
    • 12844271506 scopus 로고    scopus 로고
    • Exact reconstruction for cone-beam scanning along nonstandard spirals and other curves
    • August
    • Y.B. Ye, S.Y Zhao, H.Y. Yu and G. Wang, Exact reconstruction for cone-beam scanning along nonstandard spirals and other curves, Proceedings of SPIE, Vol. 5535, August 2004, 293-300.
    • (2004) Proceedings of SPIE , vol.5535 , pp. 293-300
    • Ye, Y.B.1    Zhao, S.Y.2    Yu, H.Y.3    Wang, G.4
  • 27
    • 25144440411 scopus 로고    scopus 로고
    • A general exact reconstruction for cone-beam CT via backprojection-filtration
    • Y. Ye, S. Zhao, H. Yu and G. Wang, A general exact reconstruction for cone-beam CT via backprojection-filtration, IEEE Trans Med Imaging 24 (2005), 1190-1198.
    • (2005) IEEE Trans Med Imaging , vol.24 , pp. 1190-1198
    • Ye, Y.1    Zhao, S.2    Yu, H.3    Wang, G.4
  • 28
    • 12844256312 scopus 로고    scopus 로고
    • Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve
    • Y. Ye and G. Wang, Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve, Med Phys 30 (2005), 42-48.
    • (2005) Med Phys , vol.30 , pp. 42-48
    • Ye, Y.1    Wang, G.2
  • 29
    • 11844249976 scopus 로고    scopus 로고
    • Cone-beam reconstruction using the backprojection of locally filtered projections
    • J.D. Pack, F. Noo and R. Clackdoyle, Cone-beam reconstruction using the backprojection of locally filtered projections, IEEE Trans Medical Imaging 24 (2005), 1-16.
    • (2005) IEEE Trans Medical Imaging , vol.24 , pp. 1-16
    • Pack, J.D.1    Noo, F.2    Clackdoyle, R.3
  • 30
    • 18744383957 scopus 로고    scopus 로고
    • Cone-beam reconstruction using ID filtering along the projection of M-lines
    • J.D. Pack and F. Noo, Cone-beam reconstruction using ID filtering along the projection of M-lines, Inverse Problems 21 (2005), 1105-1120.
    • (2005) Inverse Problems , vol.21 , pp. 1105-1120
    • Pack, J.D.1    Noo, F.2
  • 31
    • 0345733891 scopus 로고    scopus 로고
    • An alternative derivation of Katsvich's cone-beam reconstruction formula
    • G. Chen, An alternative derivation of Katsvich's cone-beam reconstruction formula, Med Phys 30 (2003), 3217-3226.
    • (2003) Med Phys , vol.30 , pp. 3217-3226
    • Chen, G.1
  • 32
    • 21144439799 scopus 로고    scopus 로고
    • A unified framework for exact cone-beam reconstruction formulas
    • S. Zhao, H. Yu and G. Wang, A unified framework for exact cone-beam reconstruction formulas, Med Phys 32 (2005), 1712-1721.
    • (2005) Med Phys , vol.32 , pp. 1712-1721
    • Zhao, S.1    Yu, H.2    Wang, G.3
  • 35
    • 0034351119 scopus 로고    scopus 로고
    • Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware
    • K. Mueller and R. Yagel, Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware, IEEE Trans Med Imaging 19(12) (2000), 1227-1237.
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.12 , pp. 1227-1237
    • Mueller, K.1    Yagel, R.2
  • 36
    • 23844499125 scopus 로고    scopus 로고
    • Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
    • X. Fang and K. Mueller, Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware. Nuclear Science, IEEE Transactions on 52(3) (2005), 654.
    • (2005) Nuclear Science, IEEE Transactions on , vol.52 , Issue.3 , pp. 654
    • Fang, X.1    Mueller, K.2
  • 38
    • 37549012458 scopus 로고    scopus 로고
    • . Friedrich-Alexander-University Erlangen-Nlrnberg, Institute of Medical Physics, Erlangen, Germany. [Online], Available: http://www.imp.uni- erlangen.de/forbild/english/results/index.htm.
    • (2001). Friedrich-Alexander-University Erlangen-Nlrnberg, Institute of Medical Physics, Erlangen, Germany. [Online], Available: http://www.imp.uni- erlangen.de/forbild/english/results/index.htm.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.