메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2013-2016

100 MHz sub-millimeter size fiber optic pressure sensors; luxury or necessity?

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC MEASUREMENTS; ACOUSTO-OPTIC; APPLICATIONS.; CALIBRATION METHODS; CALIBRATION TECHNIQUES; CONTINUOUS FUNCTIONS; CORRECTION PROCEDURE; FIBER OPTIC; FIBER OPTIC PRESSURE SENSORS; FIELD MEASUREMENTS; FINITE APERTURE; FREQUENCY RANGING; HIFU TRANSDUCERS; HIGH-FREQUENCY CHARACTERIZATION; HIGH-INTENSITY FIELDS; HIGH-INTENSITY FOCUSED ULTRASOUND; PHASE RESPONSES; PRIMARY OBJECTIVE; SENSOR FREQUENCY RESPONSE; SPATIAL AVERAGING; SUB-MILLIMETER; ULTRASONIC HYDROPHONE; ULTRASOUND FIELDS;

EID: 48149110952     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2007.506     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 1
    • 48149100377 scopus 로고    scopus 로고
    • Acoustic output measurement standard for diagnostic ultrasound equipment
    • National Electrical Manufacturers Association NEMA, Rosslyn, VA
    • Acoustic output measurement standard for diagnostic ultrasound equipment, in AIUM, Laurel MD; National Electrical Manufacturers Association (NEMA). 1998. Rosslyn, VA.
    • (1998) AIUM, Laurel MD
  • 2
    • 48149098581 scopus 로고    scopus 로고
    • FDA. Revised FDA 510(k) Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers. September 30, 1997.
    • FDA. Revised FDA 510(k) Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers. September 30, 1997.
  • 3
    • 0029409110 scopus 로고
    • Pressure pulse distortion by hydrophones due to diminished low frequency response
    • G. R. Harris, "Pressure pulse distortion by hydrophones due to diminished low frequency response," IEEE Transactions UFFC vol. 42, pp. 989-992, 1995.
    • (1995) IEEE Transactions UFFC , vol.42 , pp. 989-992
    • Harris, G.R.1
  • 4
    • 0034314458 scopus 로고    scopus 로고
    • A novel method for determining calibration and behavior of PVDF ultrasonic hydrophone probes in the frequency range up to 100 MHz, Ultrasonics, Ferroelectrics and Frequency Control
    • H. J. Bleeker and P. A. Lewin, "A novel method for determining calibration and behavior of PVDF ultrasonic hydrophone probes in the frequency range up to 100 MHz," Ultrasonics, Ferroelectrics and Frequency Control IEEE Trans. UFFC, vol. 47, pp. 1354-1362, 2000.
    • (2000) IEEE Trans. UFFC , vol.47 , pp. 1354-1362
    • Bleeker, H.J.1    Lewin, P.A.2
  • 5
    • 20144388343 scopus 로고    scopus 로고
    • Vasa vasorum imaging: A new window to the clinical detection of vulnerable atherosclerotic plaques
    • S. Carlier, I. A. Kakadiaris and N. Dib et al., "Vasa vasorum imaging: a new window to the clinical detection of vulnerable atherosclerotic plaques," Curr Atheroscler Rep, vol. 7, pp. 164-169, 2005.
    • (2005) Curr Atheroscler Rep , vol.7 , pp. 164-169
    • Carlier, S.1    Kakadiaris, I.A.2    Dib, N.3
  • 6
    • 11144352197 scopus 로고    scopus 로고
    • Bubble dynamics and size distributions during focused ultrasound insonation
    • X. Yang, R. A. Roy, and R. G. Holt, "Bubble dynamics and size distributions during focused ultrasound insonation," J. Acoust. Soc. Am., vol. 116, pp. 3423-3431, 2004.
    • (2004) J. Acoust. Soc. Am , vol.116 , pp. 3423-3431
    • Yang, X.1    Roy, R.A.2    Holt, R.G.3
  • 7
    • 33747070812 scopus 로고    scopus 로고
    • Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone
    • Y. Zhou, L. Zhai, R. Simmons, and P. Zhong, "Measurement of high intensity focused ultrasound fields by a fiber optic probe hydrophone," J. Acoust. Soc. Am., vol. 120, pp. 676-685, 2006.
    • (2006) J. Acoust. Soc. Am , vol.120 , pp. 676-685
    • Zhou, Y.1    Zhai, L.2    Simmons, R.3    Zhong, P.4
  • 8
    • 33644661136 scopus 로고    scopus 로고
    • Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields
    • J. E. Parsons, C. A. Cain, J. B. Fowlkes, "Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields," J. Acoust. Soc. Am., vol. 119, pp. 1432-1440, 2006.
    • (2006) J. Acoust. Soc. Am , vol.119 , pp. 1432-1440
    • Parsons, J.E.1    Cain, C.A.2    Fowlkes, J.B.3
  • 9
    • 0035498422 scopus 로고    scopus 로고
    • Hydrophone spatial averaging corrections from 1 to 40 MHz
    • E. G. Radulescu, P. A. Lewin, A. Goldstein, and A. Nowicki, "Hydrophone spatial averaging corrections from 1 to 40 MHz," IEEE Trans. UFFC, vol. 48, pp. 1575-1580, 2001.
    • (2001) IEEE Trans. UFFC , vol.48 , pp. 1575-1580
    • Radulescu, E.G.1    Lewin, P.A.2    Goldstein, A.3    Nowicki, A.4
  • 10
    • 0036557880 scopus 로고    scopus 로고
    • 1-60 MHz measurements in focused acoustic fields using spatial averaging corrections
    • E. G. Radulescu, P. A. Lewin, and A. Nowicki, "1-60 MHz measurements in focused acoustic fields using spatial averaging corrections," Ultrasonics, vol. 40, pp. 497-501, 2002.
    • (2002) Ultrasonics , vol.40 , pp. 497-501
    • Radulescu, E.G.1    Lewin, P.A.2    Nowicki, A.3
  • 11
    • 0037507373 scopus 로고    scopus 로고
    • Calibration of ultrasonic hydrophone probes up to 100 MHz using time gating frequency analysis and finite amplitude waves
    • E. G. Radulescu, P. A. Lewin, J. Wojcik, and A. Nowicki, "Calibration of ultrasonic hydrophone probes up to 100 MHz using time gating frequency analysis and finite amplitude waves," Ultrasonics, vol. 41, pp. 247-254, 2003.
    • (2003) Ultrasonics , vol.41 , pp. 247-254
    • Radulescu, E.G.1    Lewin, P.A.2    Wojcik, J.3    Nowicki, A.4
  • 12
    • 0037507383 scopus 로고    scopus 로고
    • Nonlinear propagation model for ultrasound hydrophones calibration in the frequency range up to 100 MHz
    • E. G. Radulescu, P. A. Lewin, J. Wojcik, and A. Nowicki, " Nonlinear propagation model for ultrasound hydrophones calibration in the frequency range up to 100 MHz," Ultrasonics, vol. 41, pp. 239-245, 2003.
    • (2003) Ultrasonics , vol.41 , pp. 239-245
    • Radulescu, E.G.1    Lewin, P.A.2    Wojcik, J.3    Nowicki, A.4
  • 13
    • 27644551519 scopus 로고    scopus 로고
    • Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz
    • P. A. Lewin, C. Mu, S. Umchid, A. Daryoush, and M. El-Sherif, "Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz," Ultrasonics, vol. 43, pp. 815-821, 2005.
    • (2005) Ultrasonics , vol.43 , pp. 815-821
    • Lewin, P.A.1    Mu, C.2    Umchid, S.3    Daryoush, A.4    El-Sherif, M.5
  • 14
    • 34948840958 scopus 로고    scopus 로고
    • Broadband PVDF Membrane hydrophone for comparisons of hydrophone calibration methods up to 140 MHz
    • V. Wilkens and W. Moltenstruck, "Broadband PVDF Membrane hydrophone for comparisons of hydrophone calibration methods up to 140 MHz," IEEE Trans, UFFC, vol 54, pp. 1784-1791, 2007.
    • (2007) IEEE Trans, UFFC , vol.54 , pp. 1784-1791
    • Wilkens, V.1    Moltenstruck, W.2
  • 16
    • 0033276975 scopus 로고    scopus 로고
    • Primary calibration of hydrophones with extended frequency range 1 - 70 MHz using optical interferometry
    • C. Koch and W. Molkenstruck, "Primary calibration of hydrophones with extended frequency range 1 - 70 MHz using optical interferometry," IEEE Trans. UFFC, vol. 46, pp. 1303-1314, 1999.
    • (1999) IEEE Trans. UFFC , vol.46 , pp. 1303-1314
    • Koch, C.1    Molkenstruck, W.2
  • 17
    • 0027624596 scopus 로고
    • Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water
    • J. Staudenraus and W. Eisenmenger, "Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water," Ultrasonics, vol. 31, pp. 267-273, 1993.
    • (1993) Ultrasonics , vol.31 , pp. 267-273
    • Staudenraus, J.1    Eisenmenger, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.