메뉴 건너뛰기




Volumn 5, Issue 4, 2008, Pages 106-109

Early clinical experience with a novel, self-centering, bi-directional vena cava filter

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAVA VEIN; CLINICAL ARTICLE; DEVICE; DEVICE REMOVAL; FILTER; FLUOROSCOPY; HUMAN; VASCULAR ACCESS; VEIN THROMBOSIS;

EID: 48149098940     PISSN: 15538036     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (15)
  • 1
    • 47049107332 scopus 로고    scopus 로고
    • Venous thrombosis and pulmonary thromboembolism
    • Greenfield LJ, Mulholland M, Oldham KT, Zelenock GB, Lillemore KD, eds, 2nd ed. Philadelphia: Lippincott-Raven Publishers
    • Greenfield LJ. Venous thrombosis and pulmonary thromboembolism. In: Greenfield LJ, Mulholland M, Oldham KT, Zelenock GB, Lillemore KD, eds. Surgery: Scientific Principles and Practice. 2nd ed. Philadelphia: Lippincott-Raven Publishers, 1997.
    • (1997) Surgery: Scientific Principles and Practice
    • Greenfield, L.J.1
  • 2
    • 0031759604 scopus 로고    scopus 로고
    • Antithrombotic therapy for venous thromboembolic disease
    • Hyers TM, Agnelli G, Hull RD, et al. Antithrombotic therapy for venous thromboembolic disease. Chest 1998;114:561-578S.
    • (1998) Chest , vol.114
    • Hyers, T.M.1    Agnelli, G.2    Hull, R.D.3
  • 3
    • 0026665992 scopus 로고
    • Inferior vena cava filters. Indications, safety, effectiveness
    • Becker DM, Philbrick JT, Selby JB. Inferior vena cava filters. Indications, safety, effectiveness. Arch Intern Med 1992;152:1985-1994.
    • (1992) Arch Intern Med , vol.152 , pp. 1985-1994
    • Becker, D.M.1    Philbrick, J.T.2    Selby, J.B.3
  • 4
    • 0024336181 scopus 로고
    • Extended indications for placement of an inferior vena cava filter
    • Rohrer MJ, Scheidler, MG, Wheeler BH. Extended indications for placement of an inferior vena cava filter. J Vasc Surg 1989;10:44-50.
    • (1989) J Vasc Surg , vol.10 , pp. 44-50
    • Rohrer, M.J.1    Scheidler, M.G.2    Wheeler, B.H.3
  • 5
    • 0031796591 scopus 로고    scopus 로고
    • Indications, management, and complications of temporary inferior ve na cava filters
    • Linsenmaier U, Rieger J, Schenk F, et al. Indications, management, and complications of temporary inferior ve na cava filters. Cardiovasc Intervent Radiol 1998;21:464-469.
    • (1998) Cardiovasc Intervent Radiol , vol.21 , pp. 464-469
    • Linsenmaier, U.1    Rieger, J.2    Schenk, F.3
  • 6
    • 0032693661 scopus 로고    scopus 로고
    • Vena cava filter for prevention of pulmonary embolism
    • Winkler WB, Slany J. Vena cava filter for prevention of pulmonary embolism. Vasa 1999;28:250-258.
    • (1999) Vasa , vol.28 , pp. 250-258
    • Winkler, W.B.1    Slany, J.2
  • 7
    • 5044235581 scopus 로고    scopus 로고
    • Outcome and complications of retrievable inferior vena cava filters
    • Stein PD, Alnas M, Skaf E, et al. Outcome and complications of retrievable inferior vena cava filters. Am J Cardiol 2004;94:1090-1093.
    • (2004) Am J Cardiol , vol.94 , pp. 1090-1093
    • Stein, P.D.1    Alnas, M.2    Skaf, E.3
  • 8
    • 0032850138 scopus 로고    scopus 로고
    • Bedside placement of inferior vena cava filters in the intensive care unit
    • Tola JC, Holtzman R, Lottenberg L. Bedside placement of inferior vena cava filters in the intensive care unit. Am Surg 1999;65:833-837.
    • (1999) Am Surg , vol.65 , pp. 833-837
    • Tola, J.C.1    Holtzman, R.2    Lottenberg, L.3
  • 9
    • 33750083034 scopus 로고    scopus 로고
    • Outcomes with retrievable inferior vena cava filters: A multicenter study
    • Ray CE Jr, Mitchell E, Zipsor S, et al. Outcomes with retrievable inferior vena cava filters: A multicenter study. J Vasc Interv Radiol 2006;17:1595-1604.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 1595-1604
    • Ray Jr, C.E.1    Mitchell, E.2    Zipsor, S.3
  • 10
    • 3042857310 scopus 로고    scopus 로고
    • Retrievability of uncoated versus paclitaxel-coated Gunther-Tulip IVC filters in an animal model
    • De Gregorio MA, Gimeno MJ, Lostale F, et al. Retrievability of uncoated versus paclitaxel-coated Gunther-Tulip IVC filters in an animal model. J Vasc Interv Radiol 2004;15:719-726.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 719-726
    • De Gregorio, M.A.1    Gimeno, M.J.2    Lostale, F.3
  • 11
    • 1542283695 scopus 로고    scopus 로고
    • Evaluation of the retrievability of the OptEase IVC filter in an animal model
    • Reekers JA, Hoogeveen YL, Wijnands M, et al. Evaluation of the retrievability of the OptEase IVC filter in an animal model. J Vasc Interv Radiol 2004;15:261-267.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 261-267
    • Reekers, J.A.1    Hoogeveen, Y.L.2    Wijnands, M.3
  • 13
    • 0037833532 scopus 로고    scopus 로고
    • A new optional vena cava filter: Retrieval at 12 weeks in an animal model
    • Brountzos EN, Kaufman JA, Venbrux AC, et al. A new optional vena cava filter: Retrieval at 12 weeks in an animal model. J Vasc Interv Radiol 2003;14:763-772.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 763-772
    • Brountzos, E.N.1    Kaufman, J.A.2    Venbrux, A.C.3
  • 14
    • 0035688667 scopus 로고    scopus 로고
    • Percutaneous retrieval of the Tulip vena cava filter: Feasibility, short- and long-term changes - an experimental study in dogs
    • Neuerburg JM, Handt S, Beckert K, et al. Percutaneous retrieval of the Tulip vena cava filter: Feasibility, short- and long-term changes - an experimental study in dogs. Cardiovasc Intervent Radiol 2001;24:418-423.
    • (2001) Cardiovasc Intervent Radiol , vol.24 , pp. 418-423
    • Neuerburg, J.M.1    Handt, S.2    Beckert, K.3
  • 15
    • 47049097691 scopus 로고    scopus 로고
    • Evaluation of the Crux IVC filter in an Animal Model
    • Murphy EH, White RA, Rosenthal D, et al. Evaluation of the Crux IVC filter in an Animal Model. J Endovasc Ther 2008;15:292-299.
    • (2008) J Endovasc Ther , vol.15 , pp. 292-299
    • Murphy, E.H.1    White, R.A.2    Rosenthal, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.