메뉴 건너뛰기




Volumn 86, Issue 2, 2008, Pages 501-505

Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty

Author keywords

Highly crosslinked polyethylene; In vivo; Total hip arthroplasty; Wear particle

Indexed keywords

SCANNING ELECTRON MICROSCOPY; THERMOPLASTICS;

EID: 47949106594     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31048     Document Type: Article
Times cited : (29)

References (28)
  • 1
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert HG. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 1977;11:157-164.
    • (1977) J Biomed Mater Res , vol.11 , pp. 157-164
    • Willert, H.G.1
  • 2
    • 0030152803 scopus 로고    scopus 로고
    • Bone formation and bone resorption in failed total joint arthroplasties: Histomorphometric analysis with histochemical and immunohistochemical technique
    • Kadoya Y, Revell PA, al-Saffar N, Kobayashi A, Scott G, Freeman MA. Bone formation and bone resorption in failed total joint arthroplasties: Histomorphometric analysis with histochemical and immunohistochemical technique. J Orthop Res 1996;14:473-482.
    • (1996) J Orthop Res , vol.14 , pp. 473-482
    • Kadoya, Y.1    Revell, P.A.2    al-Saffar, N.3    Kobayashi, A.4    Scott, G.5    Freeman, M.A.6
  • 5
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • Harris WH. The problem is osteolysis. Clin Orthop Relat Res 1995;311:46-53.
    • (1995) Clin Orthop Relat Res , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 6
    • 85130087228 scopus 로고    scopus 로고
    • Ries MD, Scott ML, Jani S. Relationship between gravimetric wear and particle generation in hip simulators: Conventional compared with cross-linked polyethylene. J Bone Joint Surg [Am] 2001;83 (Suppl 2;Part 2):116-122.
    • Ries MD, Scott ML, Jani S. Relationship between gravimetric wear and particle generation in hip simulators: Conventional compared with cross-linked polyethylene. J Bone Joint Surg [Am] 2001;83 (Suppl 2;Part 2):116-122.
  • 7
    • 0036435261 scopus 로고    scopus 로고
    • Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator
    • Saikko V, Calonius O, Keranen J. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. J Biomed Mater Res 2002;63:848-853.
    • (2002) J Biomed Mater Res , vol.63 , pp. 848-853
    • Saikko, V.1    Calonius, O.2    Keranen, J.3
  • 8
    • 47949090157 scopus 로고    scopus 로고
    • Wear particle morphology of sequential irradiated/annealed polyethylene under a "sever" wear hip simulation
    • Williams P, Bowsher J, Clarke I, Donaldson T. Wear particle morphology of sequential irradiated/annealed polyethylene under a "sever" wear hip simulation. Trans Orthop Res Soc 2006;52:630.
    • (2006) Trans Orthop Res Soc , vol.52 , pp. 630
    • Williams, P.1    Bowsher, J.2    Clarke, I.3    Donaldson, T.4
  • 9
    • 0041386214 scopus 로고    scopus 로고
    • Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator
    • D'Lima DD, Hermida JC, Chen PC, Colwell CW Jr. Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator. J Orthop Res 2003;21:761-766.
    • (2003) J Orthop Res , vol.21 , pp. 761-766
    • D'Lima, D.D.1    Hermida, J.C.2    Chen, P.C.3    Colwell Jr., C.W.4
  • 12
    • 23044492290 scopus 로고    scopus 로고
    • Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years
    • Am
    • Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A. Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg [Am] 2005;87:1816-1821.
    • (2005) J Bone Joint Surg , vol.87 , pp. 1816-1821
    • Dorr, L.D.1    Wan, Z.2    Shahrdar, C.3    Sirianni, L.4    Boutary, M.5    Yun, A.6
  • 14
    • 0141993638 scopus 로고    scopus 로고
    • Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial
    • Martell JM, Verner JJ, Incavo SJ. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial. J Arthroplasty 2003;18(7, Suppl 1):55-59.
    • (2003) J Arthroplasty , vol.18 , Issue.7 and SUPPL. 1 , pp. 55-59
    • Martell, J.M.1    Verner, J.J.2    Incavo, S.J.3
  • 15
    • 0036116447 scopus 로고    scopus 로고
    • Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
    • Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng 2002;216:111-122.
    • (2002) Proc Inst Mech Eng , vol.216 , pp. 111-122
    • Endo, M.1    Tipper, J.L.2    Barton, D.C.3    Stone, M.H.4    Ingham, E.5    Fisher, J.6
  • 16
    • 0031026881 scopus 로고    scopus 로고
    • Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- to 10-year clinical results
    • Br
    • Oonishi H, Iwaki Y, Kin N, Kushitani S, Murata N, Wakitani S, Imoto K. Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- to 10-year clinical results. J Bone Joint Surg [Br] 1997;79:87-92.
    • (1997) J Bone Joint Surg , vol.79 , pp. 87-92
    • Oonishi, H.1    Iwaki, Y.2    Kin, N.3    Kushitani, S.4    Murata, N.5    Wakitani, S.6    Imoto, K.7
  • 17
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • Br
    • Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg [Br] 1969;51;737-755.
    • (1969) J Bone Joint Surg , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 19
    • 0030880257 scopus 로고    scopus 로고
    • Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method
    • Br
    • Kobayashi A, Freeman MA, Bonfield W, Kadoya Y, Yamac T, Al-Saffar N, Scott G, Revell PA. Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method. J Bone Joint Surg [Br] 1997;79:844-848.
    • (1997) J Bone Joint Surg , vol.79 , pp. 844-848
    • Kobayashi, A.1    Freeman, M.A.2    Bonfield, W.3    Kadoya, Y.4    Yamac, T.5    Al-Saffar, N.6    Scott, G.7    Revell, P.A.8
  • 20
    • 41449113689 scopus 로고    scopus 로고
    • Characteristics of Hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties
    • Iwakiri K, Iwaki H, Kobayashi A, Minoda Y, Kagiyama H, Kodoya Y, Takaoka K. Characteristics of Hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties. J Biomed Mater Res B 2008;85:125-129.
    • (2008) J Biomed Mater Res B , vol.85 , pp. 125-129
    • Iwakiri, K.1    Iwaki, H.2    Kobayashi, A.3    Minoda, Y.4    Kagiyama, H.5    Kodoya, Y.6    Takaoka, K.7
  • 23
    • 0031239130 scopus 로고    scopus 로고
    • Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements
    • Schmalzried TP, Campbell P, Schmitt AK, Brown IC, Amstutz HC. Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements. J Biomed Mater Res 1997;38:203-210.
    • (1997) J Biomed Mater Res , vol.38 , pp. 203-210
    • Schmalzried, T.P.1    Campbell, P.2    Schmitt, A.K.3    Brown, I.C.4    Amstutz, H.C.5
  • 25
    • 0034333626 scopus 로고    scopus 로고
    • Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose
    • Matthews JB, Besong AA, Green TR, Stone MH, Wroblewski BM, Fisher J, Ingham E. Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. J Biomed Mater Res 2000;52:296-307.
    • (2000) J Biomed Mater Res , vol.52 , pp. 296-307
    • Matthews, J.B.1    Besong, A.A.2    Green, T.R.3    Stone, M.H.4    Wroblewski, B.M.5    Fisher, J.6    Ingham, E.7
  • 26
    • 0036017230 scopus 로고    scopus 로고
    • Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation
    • Yang SY, Ren W, Park Y, Sieving A, Hsu S, Nasser S, Wooley PH. Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation. Biomaterials 2002;23:3535-3543.
    • (2002) Biomaterials , vol.23 , pp. 3535-3543
    • Yang, S.Y.1    Ren, W.2    Park, Y.3    Sieving, A.4    Hsu, S.5    Nasser, S.6    Wooley, P.H.7
  • 28
    • 16244371708 scopus 로고    scopus 로고
    • Third-body wear testing of a highly cross-linked acetabular liner: The effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris
    • Bragdon CR, Jasty M, Muratoglu OK, Harris WH. Third-body wear testing of a highly cross-linked acetabular liner: The effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris. J Arthroplasty 2005;20:379-385.
    • (2005) J Arthroplasty , vol.20 , pp. 379-385
    • Bragdon, C.R.1    Jasty, M.2    Muratoglu, O.K.3    Harris, W.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.