메뉴 건너뛰기




Volumn 15, Issue 7, 2008, Pages 928-933

High-resolution Magnetic Resonance Imaging and Conventional Magnetic Resonance Imaging on a Standard Field-strength Magnetic Resonance System Compared to Arthroscopy in Patients with Suspected Meniscal Tears

Author keywords

conventional MRI; high resolution MRI; Meniscal tear of the knee joint; surface coil

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; EVALUATION; FEMALE; HIGH RESOLUTION MAGNETIC RESONANCE IMAGING; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; KNEE ARTHROSCOPY; KNEE MENISCUS RUPTURE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PERFORMANCE; PRIORITY JOURNAL; SCORING SYSTEM; SENSITIVITY ANALYSIS; SIGNAL DETECTION; THICKNESS;

EID: 47749147276     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2008.02.007     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 34247872962 scopus 로고    scopus 로고
    • MR imaging of the meniscus: Review, current trends, and clinical implications
    • Fox M.G. MR imaging of the meniscus: Review, current trends, and clinical implications. Magn Reson Imaging Clin N Am 15 (2007) 103-123
    • (2007) Magn Reson Imaging Clin N Am , vol.15 , pp. 103-123
    • Fox, M.G.1
  • 2
    • 0036838457 scopus 로고    scopus 로고
    • The meniscus: Recent advances in MR imaging of the knee
    • Helms C.A. The meniscus: Recent advances in MR imaging of the knee. AJR Am J Roentgenol 179 (2002) 1115-1122
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1115-1122
    • Helms, C.A.1
  • 3
    • 0033866193 scopus 로고    scopus 로고
    • The menisci: Basic science and advances in treatment
    • Rath E., and Richmond J.C. The menisci: Basic science and advances in treatment. Br J Sports Med 34 (2000) 252-257
    • (2000) Br J Sports Med , vol.34 , pp. 252-257
    • Rath, E.1    Richmond, J.C.2
  • 4
    • 0029910595 scopus 로고    scopus 로고
    • Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: Comparison with a conventional spin-echo sequence
    • Escobedo E.M., Hunter J.C., Zink-Brody G.C., Wilson A.J., Harrison S.D., and Fisher D.J. Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: Comparison with a conventional spin-echo sequence. AJR Am J Roentgenol 167 (1996) 1223-1227
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 1223-1227
    • Escobedo, E.M.1    Hunter, J.C.2    Zink-Brody, G.C.3    Wilson, A.J.4    Harrison, S.D.5    Fisher, D.J.6
  • 5
    • 0034112319 scopus 로고    scopus 로고
    • Current concepts and controversies in meniscal imaging
    • Rubin D.A., and Paletta Jr. G.A. Current concepts and controversies in meniscal imaging. Magn Reson Imaging Clin N Am 8 (2000) 243-270
    • (2000) Magn Reson Imaging Clin N Am , vol.8 , pp. 243-270
    • Rubin, D.A.1    Paletta Jr., G.A.2
  • 6
    • 0023894118 scopus 로고
    • Tears of the anterior cruciate ligament and menisci of the knee: MR imaging evaluation
    • Mink J.H., Levy T., and Crues III J.V. Tears of the anterior cruciate ligament and menisci of the knee: MR imaging evaluation. Radiology 167 (1988) 769-774
    • (1988) Radiology , vol.167 , pp. 769-774
    • Mink, J.H.1    Levy, T.2    Crues III, J.V.3
  • 7
    • 33746658696 scopus 로고    scopus 로고
    • 3.0-T MRI of meniscal tears
    • Magee T., and Williams D. 3.0-T MRI of meniscal tears. AJR Am J Roentgenol 187 (2006) 371-375
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 371-375
    • Magee, T.1    Williams, D.2
  • 8
    • 34248212860 scopus 로고    scopus 로고
    • Three-tesla MR imaging of the knee
    • Magee T. Three-tesla MR imaging of the knee. Magn Reson Imaging Clin N Am 15 (2007) 125-132
    • (2007) Magn Reson Imaging Clin N Am , vol.15 , pp. 125-132
    • Magee, T.1
  • 10
    • 0002072626 scopus 로고
    • Magnetic resonance imaging in the detection of meniscal injuries
    • Lotysch M., Mink J., Crues J.V., and Schwartz S.A. Magnetic resonance imaging in the detection of meniscal injuries. Magn Reson Imaging 4 (1986) 94
    • (1986) Magn Reson Imaging , vol.4 , pp. 94
    • Lotysch, M.1    Mink, J.2    Crues, J.V.3    Schwartz, S.A.4
  • 11
    • 0027249992 scopus 로고
    • MR diagnosis of meniscal tears of the knee: Importance of high signal in the meniscus that extends to the surface
    • De Smet A.A., Norris M.A., Yandow D.R., Quintana F.A., Graf B.K., and Keene J.S. MR diagnosis of meniscal tears of the knee: Importance of high signal in the meniscus that extends to the surface. AJR Am J Roentgenol 161 (1993) 101-107
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 101-107
    • De Smet, A.A.1    Norris, M.A.2    Yandow, D.R.3    Quintana, F.A.4    Graf, B.K.5    Keene, J.S.6
  • 12
    • 0037214419 scopus 로고    scopus 로고
    • Meniscal tear configurations: Categorization with MR imaging
    • Jee W.H., McCauley T.R., Kim J.M., et al. Meniscal tear configurations: Categorization with MR imaging. AJR Am J Roentgenol 180 (2003) 93-97
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 93-97
    • Jee, W.H.1    McCauley, T.R.2    Kim, J.M.3
  • 13
    • 0032974301 scopus 로고    scopus 로고
    • Comparison of low field (0.2T) and high field (1.5T) MR imaging in the differentiation of torned from intact menisci
    • Rand T., Imhof H., Turetschek K., et al. Comparison of low field (0.2T) and high field (1.5T) MR imaging in the differentiation of torned from intact menisci. Eur J Radiol 30 (1999) 22-27
    • (1999) Eur J Radiol , vol.30 , pp. 22-27
    • Rand, T.1    Imhof, H.2    Turetschek, K.3
  • 14
    • 0028924910 scopus 로고
    • Low-field versus high-field MR imaging of the knee: A comparison of signal behaviour and diagnostic performance
    • Parizel P.M., Dijkstra H.A., Geenen G.P., et al. Low-field versus high-field MR imaging of the knee: A comparison of signal behaviour and diagnostic performance. Eur J Radiol 19 (1995) 132-138
    • (1995) Eur J Radiol , vol.19 , pp. 132-138
    • Parizel, P.M.1    Dijkstra, H.A.2    Geenen, G.P.3
  • 15
    • 0034035995 scopus 로고    scopus 로고
    • MR imaging of the knee at 0.2 and 1.5 T: Correlation with surgery
    • Cotten A., Delfaut E., Demondion X., et al. MR imaging of the knee at 0.2 and 1.5 T: Correlation with surgery. AJR Am J Roentgenol 174 (2000) 1093-1097
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 1093-1097
    • Cotten, A.1    Delfaut, E.2    Demondion, X.3
  • 16
    • 7244247887 scopus 로고    scopus 로고
    • Definition of pertinent parameters for the evaluation of articular cartilage repair tissue with high-resolution magnetic resonance imaging
    • Marlovits S., Striessnig G., Resinger C.T., et al. Definition of pertinent parameters for the evaluation of articular cartilage repair tissue with high-resolution magnetic resonance imaging. Eur J Radiol 52 (2004) 310-319
    • (2004) Eur J Radiol , vol.52 , pp. 310-319
    • Marlovits, S.1    Striessnig, G.2    Resinger, C.T.3
  • 18
    • 33846052629 scopus 로고    scopus 로고
    • MR imaging of osteochondral grafts and autologous chondrocyte implantation
    • Trattnig S., Millington S.A., Szomolanyi P., and Marlovits S. MR imaging of osteochondral grafts and autologous chondrocyte implantation. Eur Radiol 17 (2007) 103-118
    • (2007) Eur Radiol , vol.17 , pp. 103-118
    • Trattnig, S.1    Millington, S.A.2    Szomolanyi, P.3    Marlovits, S.4
  • 19
    • 0028281452 scopus 로고
    • MR diagnosis of meniscal tears of the knee: Value of fast spin-echo vs conventional spin-echo pulse sequences
    • Rubin D.A., Kneeland J.B., Listerud J., Underberg-Davis S.J., and Dalinka M.K. MR diagnosis of meniscal tears of the knee: Value of fast spin-echo vs conventional spin-echo pulse sequences. AJR Am J Roentgenol 162 (1994) 1131-1135
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 1131-1135
    • Rubin, D.A.1    Kneeland, J.B.2    Listerud, J.3    Underberg-Davis, S.J.4    Dalinka, M.K.5
  • 20
    • 33749016455 scopus 로고    scopus 로고
    • Use of the "two-slice-touch" rule for the MRI diagnosis of meniscal tears
    • De Smet A.A., and Tuite M.J. Use of the "two-slice-touch" rule for the MRI diagnosis of meniscal tears. AJR Am J Roentgenol 187 (2006) 911-914
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 911-914
    • De Smet, A.A.1    Tuite, M.J.2
  • 21
    • 0030992209 scopus 로고    scopus 로고
    • Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients
    • Cheung L.P., Li K.C., Hollett M.D., Bergman A.G., and Herfkens R.J. Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients. Radiology 203 (1997) 508-512
    • (1997) Radiology , vol.203 , pp. 508-512
    • Cheung, L.P.1    Li, K.C.2    Hollett, M.D.3    Bergman, A.G.4    Herfkens, R.J.5
  • 22
    • 33646389246 scopus 로고    scopus 로고
    • Value of fat-suppressed proton-density-weighted turbo spin-echo sequences in detecting meniscal lesions: Comparison with arthroscopy
    • Schäfer F.K., Schäfer P.J., Brossmann J., et al. Value of fat-suppressed proton-density-weighted turbo spin-echo sequences in detecting meniscal lesions: Comparison with arthroscopy. Acta Radiol 47 (2006) 385-390
    • (2006) Acta Radiol , vol.47 , pp. 385-390
    • Schäfer, F.K.1    Schäfer, P.J.2    Brossmann, J.3
  • 23
    • 0033776298 scopus 로고    scopus 로고
    • MRI of the knee: Value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears
    • Kowalchuk R.M., Kneeland J.B., Dalinka M.K., Siegelman E.S., and Dockery W.D. MRI of the knee: Value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears. Skeletal Radiol 29 (2000) 520-524
    • (2000) Skeletal Radiol , vol.29 , pp. 520-524
    • Kowalchuk, R.M.1    Kneeland, J.B.2    Dalinka, M.K.3    Siegelman, E.S.4    Dockery, W.D.5
  • 24
    • 16544372575 scopus 로고    scopus 로고
    • Detection of meniscal tears and marrow lesions using coronal MRI
    • Magee T., and Williams D. Detection of meniscal tears and marrow lesions using coronal MRI. AJR Am J Roentgenol 183 (2004) 1469-1473
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1469-1473
    • Magee, T.1    Williams, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.