메뉴 건너뛰기




Volumn 174, Issue 4, 2000, Pages 1093-1097

MR imaging of the knee at 0.2 and 1.5 T: Correlation with surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANTERIOR CRUCIATE LIGAMENT RUPTURE; ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE ANALYSIS; KNEE MENISCUS RUPTURE; KNEE RADIOGRAPHY; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OBSERVER VARIATION; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL;

EID: 0034035995     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.174.4.1741093     Document Type: Article
Times cited : (67)

References (21)
  • 1
    • 0028924910 scopus 로고
    • Low-field versus high-field MR imaging of the knee: A comparison of signal behaviour and diagnostic performance
    • Parizel PM, Dijkstra HAJ, Geenen PJ, et al. Low-field versus high-field MR imaging of the knee: a comparison of signal behaviour and diagnostic performance. Eur J Radiol 1995;19:132-138
    • (1995) Eur J Radiol , vol.19 , pp. 132-138
    • Parizel, P.M.1    Dijkstra, H.A.J.2    Geenen, P.J.3
  • 2
    • 0029100763 scopus 로고
    • Comparison of low-field (0.2 Tesla) and high-field (1.5 Tesla) magnetic resonance imaging of the knee joint
    • Kladny B, Gluckert K, Swoboda B, Beyer W, Weseloh G. Comparison of low-field (0.2 Tesla) and high-field (1.5 Tesla) magnetic resonance imaging of the knee joint. Arch Orthop Trauma Surg 1995;114:281-286
    • (1995) Arch Orthop Trauma Surg , vol.114 , pp. 281-286
    • Kladny, B.1    Gluckert, K.2    Swoboda, B.3    Beyer, W.4    Weseloh, G.5
  • 3
    • 0029037009 scopus 로고
    • MRI of the knee joint: First results of a comparison of 0.2-T specialized system and 1.5-T high field strength magnet
    • Kersting-Sommerhoff B, Gerhardt P, Golder W, et al. MRI of the knee joint: first results of a comparison of 0.2-T specialized system and 1.5-T high field strength magnet. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1995;162:390-395
    • (1995) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.162 , pp. 390-395
    • Kersting-Sommerhoff, B.1    Gerhardt, P.2    Golder, W.3
  • 5
    • 0028007365 scopus 로고
    • Diagnostic performance of low field MRI in acute knee injuries
    • Kinnunen J, Bondestam S, Kivioja A, et al. Diagnostic performance of low field MRI in acute knee injuries. Magn Reson Imaging 1994;12:1155-1160
    • (1994) Magn Reson Imaging , vol.12 , pp. 1155-1160
    • Kinnunen, J.1    Bondestam, S.2    Kivioja, A.3
  • 6
    • 0343459825 scopus 로고    scopus 로고
    • Accuracy of low-field MR imaging in detection and staging meniscal lesions of the knee
    • Drape J, Coevoet V, Sarazin LR, Pessis EG, Minoui A, Chevrot A, Accuracy of low-field MR imaging in detection and staging meniscal lesions of the knee (abstr). Radiology 1997;205(P):186
    • (1997) Radiology , vol.205 , Issue.P , pp. 186
    • Drape, J.1    Coevoet, V.2    Sarazin, L.R.3    Pessis, E.G.4    Minoui, A.5    Chevrot, A.6
  • 8
    • 0028791032 scopus 로고
    • Anterior cruciate ligament tear: Prospective evaluation of diagnostic accuracy of middle- and high-field-strength MR imaging at 1.5- and 0.5-T
    • Dale Vellet A, Lee DH, Munk PL, et al. Anterior cruciate ligament tear: prospective evaluation of diagnostic accuracy of middle- and high-field-strength MR imaging at 1.5- and 0.5-T. Radiology 1995;107:826-830
    • (1995) Radiology , vol.197 , pp. 826-830
    • Dale Vellet, A.1    Lee, D.H.2    Munk, P.L.3
  • 9
    • 0023894118 scopus 로고
    • Tears of the anterior cruciate ligament and menisci of the knee: MR imaging evaluation
    • Mink JH, Levy BA, Crues JV III. Tears of the anterior cruciate ligament and menisci of the knee: MR imaging evaluation. Radiology 1988;167:769-774
    • (1988) Radiology , vol.167 , pp. 769-774
    • Mink, J.H.1    Levy, B.A.2    Crues J.V. III3
  • 10
    • 0027171844 scopus 로고
    • MR diagnosis of internal derangements of the knee: Effect of field strength on efficacy
    • Barnett MJ. MR diagnosis of internal derangements of the knee: effect of field strength on efficacy. AJR 1993;161:115-118
    • (1993) AJR , vol.161 , pp. 115-118
    • Barnett, M.J.1
  • 12
    • 84973587732 scopus 로고
    • A coefficient of agreement for nominal scales
    • Cohen J. A coefficient of agreement for nominal scales. Educ Psych Meas 1960;20:37-16
    • (1960) Educ Psych Meas , vol.20 , pp. 37-46
    • Cohen, J.1
  • 13
    • 0026094810 scopus 로고
    • Acute and chronic tears of the anterior cruciate ligament: Differential features at MR imaging
    • Vahey TN, Broome DR, Kayes KJ, Shelbourne KD. Acute and chronic tears of the anterior cruciate ligament: differential features at MR imaging. Radiology 1991;181:251-253
    • (1991) Radiology , vol.181 , pp. 251-253
    • Vahey, T.N.1    Broome, D.R.2    Kayes, K.J.3    Shelbourne, K.D.4
  • 14
    • 0023870591 scopus 로고
    • Anterior cruciate ligament tears: MR imaging compared with arthroscopy and clinical tests
    • Lee JK, Yao L, Phelps CT, Wirth CR, Czajka J, Lozman J. Anterior cruciate ligament tears: MR imaging compared with arthroscopy and clinical tests. Radiology 1988;166:861-864
    • (1988) Radiology , vol.166 , pp. 861-864
    • Lee, J.K.1    Yao, L.2    Phelps, C.T.3    Wirth, C.R.4    Czajka, J.5    Lozman, J.6
  • 15
    • 0026955015 scopus 로고
    • Menisci of the knee: Radial MR imaging correlated with arthroscopy in 259 patients
    • Quinn SE, Brown TR, Szumowski J. Menisci of the knee: radial MR imaging correlated with arthroscopy in 259 patients. Radiology 1992;185:577-580
    • (1992) Radiology , vol.185 , pp. 577-580
    • Quinn, S.E.1    Brown, T.R.2    Szumowski, J.3
  • 16
    • 0031012655 scopus 로고    scopus 로고
    • MR imaging of the knee menisci
    • Rubin DA. MR imaging of the knee menisci. Radiol Clin North Am 1997;35:21-44
    • (1997) Radiol Clin North Am , vol.35 , pp. 21-44
    • Rubin, D.A.1
  • 17
    • 0030950661 scopus 로고    scopus 로고
    • Accuracy of imaging the menisci on an in-office, magnetic resonance imaging extremity system
    • Franklin PD, Lemon RA, Barden HS. Accuracy of imaging the menisci on an in-office, magnetic resonance imaging extremity system. Am J Sports Med 1997;25:382-388
    • (1997) Am J Sports Med , vol.25 , pp. 382-388
    • Franklin, P.D.1    Lemon, R.A.2    Barden, H.S.3
  • 18
    • 0009699723 scopus 로고    scopus 로고
    • Assessment of the knee using an extremity MRI system: Diagnostic findings compared to arthroscopy
    • Shellock FG, Stone K, Crues JV III. Assessment of the knee using an extremity MRI system: diagnostic findings compared to arthroscopy (abstr). Radiology 1998;209(P):192
    • (1998) Radiology , vol.209 , Issue.P , pp. 192
    • Shellock, F.G.1    Stone, K.2    Crues J.V. III3
  • 19
    • 0032603425 scopus 로고    scopus 로고
    • 0.2-Tesla magnetic resonance imaging of internal lesions of the knee joint: A prospective arthroscopically controlled clinical study
    • Riel KA, Reinisch M, Kersting-Sommerhoff B, Hof N, Merl T. 0.2-Tesla magnetic resonance imaging of internal lesions of the knee joint: a prospective arthroscopically controlled clinical study. Knee Surg Sports Traumatol Arthrosc 1999;7:37-41
    • (1999) Knee Surg Sports Traumatol Arthrosc , vol.7 , pp. 37-41
    • Riel, K.A.1    Reinisch, M.2    Kersting-Sommerhoff, B.3    Hof, N.4    Merl, T.5
  • 20
    • 0009665048 scopus 로고    scopus 로고
    • Diagnostic accuracy of a low field strength extremity-only MR scanner in internal derangement of the knee: Correlation with arthroscopy and 1.5 Tesla MRI
    • Penrod BJ, Simmons GE, Tramo PJ, Maynard PR, Wennogle CF, Chang PS. Diagnostic accuracy of a low field strength extremity-only MR scanner in internal derangement of the knee: correlation with arthroscopy and 1.5 Tesla MRI (abstr). Radiology 1998;209(P):192
    • (1998) Radiology , vol.209 , Issue.P , pp. 192
    • Penrod, B.J.1    Simmons, G.E.2    Tramo, P.J.3    Maynard, P.R.4    Wennogle, C.F.5    Chang, P.S.6
  • 21
    • 0027452818 scopus 로고
    • Diagnosis of meniscal tears of the knee with MR imaging: Effect of observer variation and sample size on sensitivity and specificity
    • De Smet AA, Norris MA, Yandow DR, Graf BK, Keene JS. Diagnosis of meniscal tears of the knee with MR imaging: effect of observer variation and sample size on sensitivity and specificity. AJR 1993;160:555-559
    • (1993) AJR , vol.160 , pp. 555-559
    • De Smet, A.A.1    Norris, M.A.2    Yandow, D.R.3    Graf, B.K.4    Keene, J.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.